Nail over nail technique for distal locking of femoral intramedullary nails

Rajesh Rohilla1, Roop Singh1, Narender Kumar Magu1, Ashish Devgun1, Ramchander Siwach1, Ashish Gulia1
1Department of Orthopaedics, PGIMS, Rohtak, 11J-44, Medical Enclave, Rohtak, 124001, Haryana, India

Tóm tắt

Từ khóa


Tài liệu tham khảo

Aiyer S, Jagiasi J, Argekar H, Sharan S, Dasgupta B (2006) Closed antegrade interlocked nailing of femoral shaft fractures operated up to 2 weeks postinjury in the absence of a fracture table or c-arm. J Trauma 61:457–460

Bong MR, Kummer FJ, Koval KJ, Eqol KA (2007) Intramedullary nailing of the lower extremity: biomechanics and biology. J Am Acad Orthop Surg 15(2):97–106

Goodall JD (1991) An image intensifier laser guidance system for the distal locking of an intramedullary nail. Injury 22:339

Hajek PD, Bicknell HR Jr, Bronson WE, Albright JA, Saha S (1993) The use of one compared with two distal screws in the treatment of femoral shaft fractures with interlocking intramedullary nailing. A clinical and biomechanical analysis. J Bone Joint Surg 75A:519–525

Kanellopoulos AD, Yiannakopoulos CK, Vossinakis I, Badras LS (2003) Distal locking of femoral nails under direct vision through a cortical window. J Orthop Trauma 17(8):574–577

Krettek C, Konemann B, Miclau T, Kolbli R, Machreich T, Kromm A, Tscherne H (1999) A mechanical distal aiming device for distal locking in femoral nails. Clin Orthop 364:267–275

Levin PE, Schoen RW, Browner BD (1987) Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J Bone Joint Surg 69A:761–766

Mehlman CT, DiPasquale TG (1997) Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?" J Orthop Trauma 11:392–398

Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM (1998) Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 29:461–468

Owen TD, Coorsh J (1993) Insertion of the distal locking screws in femoral nailing: a simplified technique. Injury 24:101–103

Pardiwala D, Prabhu V, Dudhniwala G, Katre R (2001) The AO distal locking aiming device: an evaluation of efficacy and learning curve. Injury 32:713–718

Rao JP, Allegra MP, Benevenia J, Dauhajre TA (1989) Distal screw targeting of interlocking nails. Clin Orthop 238:245–248

Steriopoulos KA, Kontakis GM, Kantonis PG, Galanakis IA, Dretakis EK (1996) Placement of the distal locking screws of the femoral intramedullary nail without radiation. Arch Orthop Trauma Surg 115:43–44

Suhm N, Messmer P, Zuna I, Jacob LA, Reqazzoni P (2004) Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants: A prospective, controlled clinical study. Injury 35:567–574

Tanna DD (1994) Interlocking tibial nailing without an image intensifier. J Bone Joint Surg 76B:670

Tyropoulos S, Garnavos C (2001) A new distal targeting device for closed interlocking nailing. Injury 32:732–735

Whatling GM, Nokes LDM (2006) Literature review of current techniques for the insertion of distal screws into intramedullary locking nails. Injury 37:109–119

Whittle AP, Wood GW (2003) Fractures of lower extremity. In: Canale ST (ed) Campbell’s operative orthopaedics. Mosby, St. Louis, pp 2841–2845

Wu CC, Shih CH (1992) Biomechanical analysis of the mechanism of interlocking nail failure. Arch Orthop Trauma Surg 111(5):268–272

Yiannakopoulos CK, Kanellopoulos AD, Apostolou C, Antonoqiannakis E, Korres DS (2005) Distal intramedullary nail interlocking: the flag and grid technique. J Orthop Trauma 19(6):407–411

Zheng G, Zhang X, Haschtmann D, Gedet P, Lanqlotz F, Nolte LP (2007) Accurate and reliable pose recovery of distal locking holes in computer-assisted intramedullary nailing of femoral shaft fractures: a preliminary study. Comput Aided Surg 12:138–151