This study investigated changes in metal-on-metal (MOM) hip wear and wear particle characteristics arising from a more aggressive patient activity level compared with normal walking. The test hypothesis was that ‘severe’-gait conditions will change wear, wear particle sizes, and morphology owing to a decline in joint lubrication. Four carbon MOM hip bearings 40 mm high were subjected to normal-walking and fast-jogging simulations in an orbital hip joint simulator with 25 per cent α-calf serum as a lubricant. Co-Cr-Mo wear particles were extracted using an enzymatic method, and prolate ellipsoid equations were used to estimate particle volume and surface area. Fast-jogging simulations generated a sevenfold increase in volumetric wear, a 33 per cent increase in mean wear particle size, and a threefold increase in the number of larger (needle) particles compared with walking. This resulted in a twentyfold increase in total wear particle surface area per 106 cycles compared with walking, thereby confirming our hypothesis. The clinical significance of this result suggests that highly active MOM patients may exhibit greater ion release than less active patients.

Từ khóa


Tài liệu tham khảo

Takahashi T., Kuiper J. H., Gile S., Sieniawska C., Richardson M. D. Effect of exercise on metal levels in patients with three different metal-on-metal hip replacements. In Proceedings of the American Academy of Orthopaedic Surgery, San Francisco, California, USA, 2004, p. 71.

10.2106/00004623-200504000-00013

10.1016/j.arth.2004.09.009

Jacobs J. J., 2003, Clin. Orthop., 417, 139, 10.1097/01.blo.0000096810.78689.62

10.1302/0301-620X.85B6.14166

10.1302/0301-620X.77B6.7593115

Soh E. W., Blunn G. W., Wait M. E., Walker P. S. Size and shape of metal particles from metal-on-metal total hip replacements. Transactions of the 42nd Orthopaedic Research Society Meeting, Georgia, USA, 1996, Vol. 21, p. 462.

10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO;2-M

10.1002/jbm.b.20036

Firkins P. J., Tipper J. L., Ingham E., Stone M. H., Farrar R., Fisher J. Quantitative analysis of wear debris from metal-on-metal hip prosthesis tested in a physiological hip joint simulator. Transactions of the 45th Orthopaedic Research Society, Anaheim, California, USA, 1999, Vol. 24, p. 49.

10.1023/A:1026473723777

Fisher J., Besong A. A., Firkins P. J., Barbour P. S.M., Comparative wear and debris generation in UHMWPE on ceramic, metal-on-metal and ceramic on ceramic hip prostheses. Transactions of the 46th Orthopaedic Research Society Meeting, Orlando, Florida, 2000, Vol. 25, p. 587.

10.1002/jbm.a.10088

Brown C., Tipper J. L., Fisher J., Ingham E. Use of high resolution microscopy to characterise wear debris produced by metal-on-metal hip simulation. Transactions of the 50th Orthopaedic Research Society Meeting, San Francisco, California, USA, 2004, Vol. 29, p. 1512.

10.1002/jbm.b.30052

Dorr L. D., 2000, J. Bone Jt Surg., 83, 783

Chan F. W., Bobyn J. D., Medley J. B., Krygier J. J. Simulator wear of metal-metal hip implants under adverse load conditions. Transactions of the 45th Orthopaedic Research Society Meeting, Anaheim, California, USA, 1999, Vol. 24, p. 310.

10.1243/0954411011533481

Butterfield M., Stewart T., Williams S., Ingham E., Stone M., Fisher J. Wear of metal-metal and ceramic-ceramic hip prostheses with swing phase microseparation. Transactions of the 48th Orthopaedic Research Society Meeting, Dallas, Texas, USA, 2002, Vol. 27, p. 128.

Lu B., Marti A., McKellop H. Wear of a second-generation metal-on-metal hip replacement effect of third-body abrasive particles. Sixth World Biomaterials Congress, California, USA, 2000, p. 183.

Bowsher J. G., Nevelos J., Pickard J., Shelton J. C. Do heat treatments influence the wear of large diameter metal-on-metal hip joints? an in vitro study under normal and adverse gait conditions, Transactions of the 49th Orthopaedic Research Society Meeting, New Orleans, Louisianna, USA, 1–5 February 2003, Vol. 28, p. 1398.

Liao Y.S., Fryman C., Hanes M., Turner L. Effects of clearance, head size, and start-stop protocol on wear of metal-on-metal hip joints bearings in a physiological anatomical hip joint simulator. Transactions of the 50th Orthopaedic Research Society Meeting, San Francisco, California, USA, 8 March 2004, Vol. 29, p. 1454.

10.1097/00003086-199608001-00013

10.1302/0301-620X.81B1.9047

Rieker C. B., Koettig P., Rieder V., Shen M. In-vivo volumetric wear rate of modern metal-metal bearings. 30th Annual Meeting of Society for Biomaterials Transactions, Memphis, Tennessee, USA, April 2005, p. 84.

10.1016/S0043-1648(01)00619-6

McKellop H. A., Corrosion and Degradation of Implant Materials, 351

Paul J. P., 1966, Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 181, 8

10.1016/0021-9290(93)90058-M

10.1016/S0043-1648(01)00654-8

10.1002/jbm.b.30132

Catelas I., Bobyn D., Vali H., Medley J. B., Campbell P. A., Zukov D. J., Pétit A., Huk D. L. Changes in metal-metal wear particle characteristics with isolation protocols. Transactions of the 46th Orthopaedic Research Society Meeting, Orlando, Florida, USA, 2000, Vol. 25, p. 26.

10.1016/S0142-9612(02)00360-5