Mechanical loads at the knee joint during deep flexion

Journal of Orthopaedic Research - Tập 20 - Trang 881-886 - 2002
Takeo Nagura1, Chris O Dyrby1, Eugene J Alexander1, Thomas P Andriacchi1
1Division of Biomechanical Engineering, Department of Mechanical Engineering, Stanford University, Durand Building, 227 Stanford, CA 94305-3030, USA

Tóm tắt

AbstractThere is a lack of fundamental information on the knee biomechanics in deep flexion beyond 90°. In this study, mechanical loads during activities requiring deep flexion were quantified on normal knees from 19 subjects, and compared with those in walking and stair climbing. The deep flexion activities generate larger net quadriceps moments (6.9–13.5% body weight into height) and net posterior forces (58.3–67.8% body weight) than routine ambulatory activities. Moreover, the peak net moments and the net posterior forces were generated between 90° and 150° of flexion.The large moments and forces will result in high stress at high angles of flexion. These loads can influence pathological changes to the joint and are important considerations for reconstructive procedures of the knee. The posterior cruciate ligament should have a substantial role during deep flexion, since there was a large posterior load that must be sustained at the knee. The mechanics of the knee in deep flexion are likely a factor causing problems of posterior instability in current total knee arthroplasty. Thus, it is important to consider the magnitude of the loads at the knee in the treatment of patients that commonly perform deep flexion during activities of daily living. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.

Tài liệu tham khảo

10.2106/00004623-198062050-00008 10.2106/00004623-198264090-00008 10.2106/00004623-198062020-00013 Cohen B, 1992, Subluxation of the posterior stabilized total knee arthroplasty. A report of two cases, J Arthroplasty, 7, 161, 10.1016/0883-5403(92)90010-N 10.1243/EMED_JOUR_1982_011_019_02 10.1016/0021-9290(94)00172-Z Dyrby CO, 1997, Relation between knee flexion and tibial‐femoral rotation during activities involving deep flexion, Gait Posture, 5, 179, 10.1016/S0966-6362(97)83424-8 10.1016/S1350-4533(98)00024-1 10.1002/jor.1100160608 Insall JN, 1982, The posterior stabilized condylar prosthesis. Two to four year clinical experience, J Bone Joint Surg [Am], 64, 1317, 10.2106/00004623-198264090-00006 10.5271/sjweh.127 Kim J, 1995, Squatting following total knee arthroplasty, Clin Orthop, 313, 177 Maloney WJ, 1992, The effects of implant design on range of motion after total knee arthroplasty, Clin Orthop, 278, 147, 10.1097/00003086-199205000-00024 Maquet PG, 1975, Femorotibial weight‐bearing areas. Experimental determination, J Bone Joint Surg [Am], 57, 766, 10.2106/00004623-197557060-00005 Markolf KL, 1976, Stiffness and laxity of the knee: the contributions of the supporting structures. A quantitative in vitro study, J Bone Joint Surg [Am], 58, 583, 10.2106/00004623-197658050-00001 Matusda S, 1997, Patellofemoral joint after total knee arthroplasty. Effect on contact area and contact stress, J Arthroplasty, 12, 790, 10.1016/S0883-5403(97)90010-3 Matsuda S, 1999, Knee stability in posterior cruciate ligament retaining total knee arthroplasty, Clin Orthop, 366, 169, 10.1097/00003086-199909000-00021 10.1002/jor.1100060207 10.1016/0021-9290(70)90050-3 10.1097/00003086-199811000-00008 10.1097/00003086-199910000-00024 10.1002/jor.1100090114 10.1016/0021-9290(75)90089-5 Sharkey PF, 1992, Posterior dislocation of total knee arthroplasty, Clin Orthop, 278, 128, 10.1097/00003086-199205000-00021 Shoji H, 1987, Improved range of motion with the Y/S total knee arthroplasty system, Clin Orthop, 218, 150, 10.1097/00003086-198705000-00022 10.1054/arth.2000.4638 Striplin DB, 1992, Posterior dislocation of the Insall/Burstein II posterior stabilized total knee prosthesis, Am J Knee Surg, 5, 79 Thun M, 1987, Morbidity from repetitive knee trauma in carpet and floor layers, Br J Ind Med, 44, 611 10.1302/0301-620X.82B4.10651 Whiteside LA, 1994, Cementless total knee replacement. Nine to 11 year‐results and 10‐year survivorship analysis, Clin Orthop, 309, 185