Measurement and Estimation of GFR in Children and Adolescents

Clinical journal of the American Society of Nephrology : CJASN - Tập 4 Số 11 - Trang 1832-1843 - 2009
George J. Schwartz1,2,3, Dana F. Work1,2,3
1Department of Pediatrics, University of Rochester School of Medicine, Golisano Children's Hospital at Strong, Rochester, New York
2e-mail: [email protected]
3Fax: +585-756-8054

Tóm tắt

Từ khóa


Tài liệu tham khảo

Brodehl, 1982, Postnatal development of tubular phosphate reabsorption, Clin Nephrol, 17, 163

West, 1948, Glomerular filtration rate, effective renal blood flow, and maximal tubular excretory capacity in infancy, J Pediatr, 32, 10, 10.1016/S0022-3476(48)80124-1

Rubin, 1949, Maturation of renal function in childhood: Clearance studies, J Clin Invest, 28, 1144, 10.1172/JCI102149

Schwartz, 2009, New equations to estimate GFR in children with CKD, J Am Soc Nephrol, 20, 629, 10.1681/ASN.2008030287

Haycock, 1978, Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults, J Pediatr, 93, 62, 10.1016/S0022-3476(78)80601-5

Sapirstein, 1955, Volumes of distribution and clearances of intravenously injected creatinine in the dog, Am J Physiol, 181, 330, 10.1152/ajplegacy.1955.181.2.330

Gibb, 2009, Measurement of glomerular filtration rate in children with insulin-dependent diabetes mellitus, Clinica Chimica Acta, 182, 131, 10.1016/0009-8981(89)90072-7

Arant, 1972, The congruence of creatinine and inulin clearances in children: Use of the Technicon AutoAnalyzer, J Pediatr, 81, 559, 10.1016/S0022-3476(72)80191-4

Sarnak, 2003, Kidney disease as a risk factor for development of cardiovascular disease: a statement from the American Heart Association Councils on Kidney in Cardiovascular Disease, High Blood Pressure Research, Clinical Cardiology, and Epidemiology and Prevention, Circulation, 108, 2154, 10.1161/01.CIR.0000095676.90936.80

Winterborn, 1977, Comparison of plasma disappearance and standard clearance techniques for measuring glomerular filtration rate in children with and without vesico-ureteric reflux, Clin Nephrol, 7, 262

Cole, 1972, Measurement of renal function without urine collection, N Engl J Med, 287, 1109, 10.1056/NEJM197211302872202

Rahn, 1999, How to assess glomerular function and damage in humans, J Hypertens, 17, 309, 10.1097/00004872-199917030-00002

Swinkels, 2000, Glomerular filtration rate by single-injection inulin clearance: definition of a workable protocol for children, Ann Clin Biochem, 37, 60, 10.1258/0004563001901533

Schwartz, 2006, Glomerular filtration rate via plasma iohexol disappearance: Pilot study for chronic kidney disease in children, Kidney Int, 69, 2070, 10.1038/sj.ki.5000385

Brochner-Mortensen, 1972, A simple method for the determination of glomerular filtration rate, Scand J Clin Lab Invest, 30, 271, 10.3109/00365517209084290

Orlando, 1998, Determination of inulin clearance by bolus intravenous injection in healthy subjects and ascitic patients: Equivalence of systemic and renal clearances as glomerular filtration markers, Br J Clin Pharmacol, 46, 605, 10.1046/j.1365-2125.1998.00824.x

Odeh, 1993, : Simultaneous analysis of inulin and 15N2-urea kinetics in humans, Clin Pharmacol Ther, 53, 419, 10.1038/clpt.1993.45

van Rossum, 2005, Determination of inulin clearance by single injection or infusion in children, Pediatr Nephrol, 20, 777, 10.1007/s00467-004-1782-8

Guadino, 1949, Kinetics of distribution of inulin between two body water compartments, Proc Soc Exp Biol Med, 68, 672, 10.3181/00379727-70-17029

Gaspari, 1995, Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate, J Am Soc Nephrol, 6, 257, 10.1681/ASN.V62257

Chantler, 1972, Estimation of glomerular filtration rate from plasma clearance of 51-Chromium edetic acid, Arch Dis Childh, 47, 613, 10.1136/adc.47.254.613

Chantler, 1969, Glomerular filtration rate measurement in man by the single injection method using 51Cr-EDTA, Clin Sci, 37, 169

Brochner-Mortensen, 1974, A simple method for accurate assessment of the glomerular filtration rate in children, Scand J Clin Lab Invest, 33, 139, 10.3109/00365517409082481

Garnett, 1967, Measurement of glomerular filtration-rate in man using a 51Cr/EDETIC-acid complex, Lancet, i, 818, 10.1016/S0140-6736(67)92781-X

Hellerstein, 1993, The renal clearance and infusion clearance of inulin are similar, but not identical, Kidney Int, 44, 1058, 10.1038/ki.1993.348

Olsson, 1983, Human pharmacokinetics of iohexol: A new nonionic contrast medium, Invest Radiol, 18, 177, 10.1097/00004424-198303000-00015

Back, 1988, Contrast media as markers for glomerular filtration: A pharmacokinetic comparison of four agents, Scand J Clin Lab Invest, 48, 247, 10.3109/00365518809167491

Krutzen, 1984, Plasma clearance of a new contrast agent, iohexol: A method for the assessment of glomerular filtration rate, J Lab Clin Med, 104, 955

Nilsson-Ehle, 1994, New markers for the determination of GFR: Iohexol clearance and cystatin C serum concentration, Kidney Int, 46, S17

Brown, 1991, Iohexol clearance for the determination of glomerular filtration rate in clinical practice: Evidence for a new gold standard, J Urol, 146, 675, 10.1016/S0022-5347(17)37891-6

Erley, 2001, Plasma clearance of iodine contrast media as a measure of glomerular filtration rate in critically ill patients, Crit Care Med, 29, 1544, 10.1097/00003246-200108000-00008

Nilsson-Ehle, 2001, Iohexol clearance for the determination of glomerular filtration rate: 15 years' experience in clinical practice, J Int Fed Clin Chem Lab Med, 13, 1

Sterner, 1996, Iohexol clearance for GFR-determination in renal failure—single or multiple plasma sampling?, Nephrol Dial Transplant, 11, 521

Stake, 1991, The clearance of iohexol as a measure of the glomerular filtration rate in children with chronic renal failure, Scand J Clin Lab Invest, 51, 729, 10.3109/00365519109104587

Brion, 1986, A simple estimate of glomerular filtration rate in low birth weight infants during the first year of life: Noninvasive assessment of body composition and growth, J Pediatr, 109, 698, 10.1016/S0022-3476(86)80245-1

Niculescu-Duvaz, 2006, Development of an outpatient finger-prick glomerular filtration rate procedure suitable for epidemiological studies, Kidney Int, 69, 1272, 10.1038/sj.ki.5000240

Piepsz, 1978, A simple method for measuring separate glomerular filtration rate using a single injection of 99mTc-DTPA and the scintillation camera, J Pediatr, 93, 769, 10.1016/S0022-3476(78)81074-9

Rehling, 1984, Simultaneous measurement of renal clearance and plasma clearance of 99mTc-labelled diethylenetriaminepenta-acetate, 51Cr-labelled ethylenediaminetetra-acetate and inulin in man, Clin Sci, 66, 613, 10.1042/cs0660613

Carlsen, 1980, Comparison of four commercial Tc-99m(Sn)DTPA preparations used for the measurement of glomerular filtration rate: Concise communication, J Nucl Med, 21, 126

Piepsz, 2006, Revisiting normal (51)Cr-ethylenediaminetetraacetic acid clearance values in children, Eur J Nucl Med Mol Imaging, 33, 1477, 10.1007/s00259-006-0179-2

Silkalns, 1973, Simultaneous measurement of glomerular filtration rate and renal plasma flow using plasma disappearance curves, J Pediatr, 83, 749, 10.1016/S0022-3476(73)80365-8

Bajaj, 1996, 125Iodine-iothalamate clearance in children. A simple method to measure glomerular filtration, Pediatr Nephrol, 10, 25, 10.1007/BF00863432

Zappitelli, 2006, Derivation and validation of cystatin C-based prediction equations for GFR in children, Am J Kidney Dis, 48, 221, 10.1053/j.ajkd.2006.04.085

Hellerstein, 1998, Creatinine clearance following cimetidine for estimation of glomerular filtration rate, Pediatr Nephrol, 12, 49, 10.1007/s004670050402

Hellerstein, 2006, Timed-urine collections for renal clearance studies, Pediatr Nephrol, 21, 96, 10.1007/s00467-005-2036-0

Waller, 1991, The accuracy of creatinine clearance with and without urine collection as a measure of glomerular filtration rate, Postgrad Med J, 67, 42, 10.1136/pgmj.67.783.42

Levey, 1993, Glomerular filtration rate measurements in clinical trials, J Am Soc Nephrol, 4, 1159, 10.1681/ASN.V451159

Greenblatt, 1976, Variability of 24-hour urinary creatinine excretion by normal subjects, J Clin Pharmacol, 16, 321, 10.1002/j.1552-4604.1976.tb01527.x

Odlind, 1985, Is 125I iothalamate an ideal marker for glomerular filtration?, Kidney Int, 27, 9, 10.1038/ki.1985.3

Mitch, 1978, A proposed mechanism for reduced creatinine excretion in severe chronic renal failure, Nephron, 21, 248, 10.1159/000181400

Levey, 1988, Serum creatinine and renal function, Annu Rev Med, 39, 465, 10.1146/annurev.me.39.020188.002341

van Acker, 1992, Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate, Lancet, 340, 1326, 10.1016/0140-6736(92)92502-7

Schwartz, 1976, A simple estimate of glomerular filtration rate in children derived from body length and plasma creatinine, Pediatrics, 58, 259, 10.1542/peds.58.2.259

Schwartz, 1987, The use of plasma creatinine concentration for estimating glomerular filtration rate in infants, children, and adolescents, Pediatr Clin North Am, 34, 571, 10.1016/S0031-3955(16)36251-4

Schwartz, 1984, A simple estimate of glomerular filtration rate in full-term infants during the first year of life, J Pediatr, 104, 849, 10.1016/S0022-3476(84)80479-5

Schwartz, 1985, A simple estimate of glomerular filtration rate in adolescent boys, J Pediatr, 106, 522, 10.1016/S0022-3476(85)80697-1

Schwartz, 1976, Plasma creatinine and urea concentration in children: normal values for age and sex, J Pediatr, 88, 828, 10.1016/S0022-3476(76)81125-0

Clermont, 1986, Reliability of plasma creatinine measurement in infants and children, Clin Pediatr, 25, 569, 10.1177/000992288602501106

Filler, 2002, β-Trace protein, cystatin C, β2-microglobulin, and creatinine compared for detecting impaired glomerular filtration rates in children, Clin Chem, 48, 729, 10.1093/clinchem/48.5.729

Schwartz, 2009, Validation of creatinine assays utilizing HPLC and IDMS traceable standards in sera of children, Pediatr Nephrol, 24, 113, 10.1007/s00467-008-0957-0

Myers, 2006, Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program, Clin Chem, 52, 5, 10.1373/clinchem.2005.0525144

Levey, 1999, A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation, Ann Intern Med, 130, 461, 10.7326/0003-4819-130-6-199903160-00002

Filler, 2005, The Cockcroft-Gault formula should not be used in children, Kidney Int, 67, 2321, 10.1111/j.1523-1755.2005.00336.x

Pierrat, 2003, Predicting GFR in children and adults: A comparison of the Cockcroft-Gault, Schwartz, and Modification of Diet in Renal Disease formulas, Kidney Int, 64, 1425, 10.1046/j.1523-1755.2003.00208.x

Mattman, 2006, Estimating pediatric glomerular filtration rates in the era of chronic kidney disease staging, J Am Soc Nephrol, 17, 487, 10.1681/ASN.2005010034

Counahan, 1976, Estimation of glomerular filtration rate from plasma creatinine concentration in children, Arch Intern Med, 51, 875

Cockcroft, 1976, Prediction of creatinine clearance from serum creatinine, Nephron, 16, 31, 10.1159/000180580

Leger, 2002, Estimation of glomerular filtration rate in children, Pediatr Nephrol, 17, 903, 10.1007/s00467-002-0964-5

Newman, 2002, Cystatin C, Ann Clin Biochem, 39, 89, 10.1258/0004563021901847

Finney, 2000, Reference ranges for plasma cystatin C and creatinine measurements in premature infants, neonates, and older children, Arch Dis Childh, 82, 71, 10.1136/adc.82.1.71

Bökenkamp, 1998, Reference values for cystatin C serum concentrations in children, Pediatr Nephrol, 12, 125, 10.1007/s004670050419

Tenstad, 1996, Renal handling of radiolabelled human cystatin C in the rat, Scand J Clin Lab Invest, 56, 409, 10.3109/00365519609088795

Groesbeck, 2008, Age, gender, and race effects on cystatin C levels in US adolescents, Clin J Am Soc Nephrol, 3, 1777, 10.2215/CJN.00840208

Grubb, 1992, Diagnostic value of analysis of cystatin C and protein HC in biological fluids, Clin Nephrol, 38, S20

Keevil, 1998, Biological variation of cystatin C: Implications for the assessment of glomerular filtration rate, Clin Chem, 44, 1535, 10.1093/clinchem/44.7.1535

Flodin, 2006, Variations in assay protocol for the Dako cystatin C method may change patient results by 50% without changing the results for controls, Clin Chem Lab Med, 44, 1481, 10.1515/CCLM.2006.271

Dworkin, 2001, Serum cystatin C as a marker of glomerular filtration rate, Curr Opin Nephrol Hypertension, 10, 551, 10.1097/00041552-200109000-00001

Coll, 2000, Serum cystatin C as a new marker for noninvasive estimation of glomerular filtration rate and as a marker for early renal impairment, Am J Kid Dis, 36, 29, 10.1053/ajkd.2000.8237

Christensson, 2003, Serum cystatin C is a more sensitive and more accurate marker of glomerular filtration rate than enzymatic measurements of creatinine in renal transplantation, Nephron Physiol, 94, 19, 10.1159/000071287

Stickle, 1998, Correlation of plasma concentrations of cystatin C and creatinine to inulin clearance in a pediatric population, Clin Chem, 44, 1334, 10.1093/clinchem/44.6.1334

Filler, 1999, Diagnostic sensitivity of serum cystatin for impaired glomerular filtration rate, Pediatr Nephrol, 13, 501, 10.1007/s004670050646

Ylinen, 1999, Cystatin C as a marker for glomerular filtration rate in pediatric patients, Pediatr Nephrol, 13, 506, 10.1007/s004670050647

Laterza, 2002, An improved estimator of glomerular filtration rate?, Clin Chem, 48, 699, 10.1093/clinchem/48.5.699

Filler, 2003, Should the Schwartz formula for estimation of GFR be replaced by cystatin C formula?, Pediatr Nephrol, 18, 981, 10.1007/s00467-003-1271-5

Knight, 2004, Factors influencing serum cystatin C levels other than renal function and the impact on renal function measurement, Kidney Int, 65, 1416, 10.1111/j.1523-1755.2004.00517.x

Risch, 2001, Effects of glucocorticoid immunosuppression on serum cystatin C concentrations in renal transplant patients, Clin Chem, 47, 2055, 10.1093/clinchem/47.11.2055

Holmquist, 2003, Metabolic status in diabetes mellitus affects markers for glomerular filtration rate, Pediatr Nephrol, 18, 536, 10.1007/s00467-003-1086-4

Fricker, 2003, Impact of thyroid dysfunction on serum cystatin C, Kidney Int, 63, 1944, 10.1046/j.1523-1755.2003.00925.x

Tkaczyk, 2004, Increased cystatin C concentration in urine of nephrotic children, Pediatr Nephrol, 19, 1278, 10.1007/s00467-004-1566-1

Uchida, 2002, Measurement of cystatin-C and creatinine in urine, Clin Chim Acta, 323, 121, 10.1016/S0009-8981(02)00177-8

Bouvet, 2006, GFR is better estimated by considering both serum cystatin C and creatinine levels, Pediatr Nephrol, 21, 1299, 10.1007/s00467-006-0145-z

Hogg, 2003, National Kidney Foundation's kidney disease outcomes quality initiative clinical practice guidelines for chronic kidney disease in children and adolescents: Evaluation, classification, and stratification, Pediatrics, 111, 1416, 10.1542/peds.111.6.1416

Grubb, 2005, Simple cystatin C-based prediction equations for glomerular filtration rate compared with the modification of diet in renal disease prediction equation for adults and the Schwartz and the Counahan-Barratt prediction equations for children, Clin Chem, 51, 1420, 10.1373/clinchem.2005.051557

Kuczmarski, 2002, 2000 CDC Growth Charts for the United States: methods and development, Vital Health Stat, 11, 1