Tóm tắt

To investigate the influence of iodinated contrast medium (ICM) on detection of monosodium urate (MSU) with dual-energy computed tomography (DECT) in two types of phantoms and demonstrate an example patient for clinical illustration. Approval is by the institutional review board, and written informed consent was obtained. A grid-like and a biophantom with 25 suspensions containing different concentrations of ICM (0 to 2%) and MSU (0 to 50%) were prepared and scanned with sequential single-source DECT using established methodology. Ascending orders of tube currents were applied at 80 kVp (16.5 to 220.0 mAs) and 135 kVp (2.75 to 19.25 mAs). Volume and mass measurements were performed using clinical gout software (dual-energy decomposition analysis). Numbers of true-positive and false-positive MSU detections were recorded and compared for different ICM concentrations. We demonstrate a patient with gouty arthritis for clinical illustration. Effects of ICM on MSU detection varied with the amount of iodine. Lower ICM concentrations (0.25 and 0.50%) improved detection of small uric acid concentrations of 35 to 45% in comparison to scans without ICM. However, high ICM concentrations (1 and 2%) almost completely precluded MSU detection for all MSU concentrations investigated. In a patient with gouty arthritis, tophi in the wrist were only detected after intravenous ICM administration. Exploring multimodal DECT for arthritis imaging, enhancement of ICM influences tophus detection. It can help in visualizing previously undetected MSU depositions but, with too strong enhancement, also obscure tophi. Use of iodinated contrast media in dual-energy CT might help in visualizing previously undetected uric acid depositions but, with too strong enhancement, obscure gouty tophi. • Iodine significantly influences the uric acid crystal detection in systematic phantom studies. • Lower iodine concentrations improved detection of low and medium uric acid concentrations. • High concentrations of iodine hampered detection of all uric acid concentrations.

Tài liệu tham khảo

Chhana A, Dalbeth N (2015) The gouty tophus: a review. Curr Rheumatol Rep 17:19. https://doi.org/10.1007/s11926-014-0492-x Nunes EA, Rosseti AG Jr, Ribeiro DS, Santiago M (2014) Gout initially mimicking rheumatoid arthritis and later cervical spine involvement. Case Rep Rheumatol 2014:357826. https://doi.org/10.1155/2014/357826 Lopez-Reyes A, Hernandez-Diaz C, Hofmann F, Pineda C (2012) Gout mimicking psoriatic arthritis flare. J Clin Rheumatol 18:220. https://doi.org/10.1097/RHU.0b013e318259aa2e Carotti M, Salaffi F, Filippucci E et al (2020) Clinical utility of dual energy computed tomography in gout: current concepts and applications. Acta Biomed 91:116–124. https://doi.org/10.23750/abm.v91i8-S.9942 Wang Y, Deng X, Xu Y, Ji L, Zhang Z (2018) Detection of uric acid crystal deposition by ultrasonography and dual-energy computed tomography: a cross-sectional study in patients with clinically diagnosed gout. Medicine (Baltimore) 97:e12834. https://doi.org/10.1097/MD.0000000000012834 Goo HW, Goo JM (2017) Dual-energy CT: new horizon in medical imaging. Korean J Radiol 18:555–569. https://doi.org/10.3348/kjr.2017.18.4.555 Fukuda T, Umezawa Y, Asahina A, Nakagawa H, Furuya K, Fukuda K (2017) Dual energy CT iodine map for delineating inflammation of inflammatory arthritis. Eur Radiol 27:5034–5040. https://doi.org/10.1007/s00330-017-4931-8 Fukuda T, Umezawa Y, Tojo S et al (2017) Initial experience of using dual-energy CT with an iodine overlay image for hand psoriatic arthritis: comparison study with contrast-enhanced MR imaging. Radiology 284:134–142. https://doi.org/10.1148/radiol.2016161671 Ulas ST, Ziegeler K, Richter ST et al (2022) Contrast-enhanced CT techniques and MRI perform equally well in arthritis imaging of the hand: a prospective diagnostic accuracy study. Eur Radiol 32:6376–6383. https://doi.org/10.1007/s00330-022-08744-0 Ulas ST, Hermann KG, Makowski MR et al (2021) Perfusion in hand arthritis on dynamic contrast-enhanced computed tomography: a randomized prospective study using MRI as a standard of reference. Skeletal Radiol 50:59–68. https://doi.org/10.1007/s00256-020-03526-5 Yang CY, Chen YF, Lee CW et al (2008) Multiphase CT angiography versus single-phase CT angiography: comparison of image quality and radiation dose. AJNR Am J Neuroradiol 29:1288–1295. https://doi.org/10.3174/ajnr.A1073 Melzer R, Pauli C, Treumann T, Krauss B (2014) Gout tophus detection-a comparison of dual-energy CT (DECT) and histology. Semin Arthritis Rheum 43:662–665. https://doi.org/10.1016/j.semarthrit.2013.11.002 Dalbeth N, House ME, Aati O et al (2015) Urate crystal deposition in asymptomatic hyperuricaemia and symptomatic gout: a dual energy CT study. Ann Rheum Dis 74:908–911. https://doi.org/10.1136/annrheumdis-2014-206397 Diekhoff T, Kiefer T, Stroux A et al (2015) Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies. Invest Radiol 50:255–260. https://doi.org/10.1097/RLI.0000000000000099 Diekhoff T, Kotlyarov M, Mews J, Hamm B, Hermann KGA (2018) Iterative reconstruction may improve diagnosis of gout: an ex vivo (bio)phantom dual-energy computed tomography study. Invest Radiol 53:6–12. https://doi.org/10.1097/RLI.0000000000000402 Kotlyarov M, Hermann KGA, Mews J, Hamm B, Diekhoff T (2020) Development and validation of a quantitative method for estimation of the urate burden in patients with gouty arthritis using dual-energy computed tomography. Eur Radiol 30:404–412. https://doi.org/10.1007/s00330-019-06350-1 European Commission (2008) CT safety & efficacy: a broad perspective. 2004 CT quality criteria. Appendix A - MSCT dosimetry, guidelines on radiation dose to the patient. Available via http://www.biophysicssite.com/Documents/MSCT2004b/Appendix_A_MSCT_Dosimetry.pdf. Accessed 17 Mar 2023 Saltybaeva N, Jafari ME, Hupfer M, Kalender WA (2014) Estimates of effective dose for CT scans of the lower extremities. Radiology 273:153–159. https://doi.org/10.1148/radiol.14132903 Patil P, Dasgupta B (2012) Role of diagnostic ultrasound in the assessment of musculoskeletal diseases. Ther Adv Musculoskelet Dis 4:341–355. https://doi.org/10.1177/1759720X12442112 Combe B, Landewe R, Daien CI et al (2017) 2016 update of the EULAR recommendations for the management of early arthritis. Ann Rheum Dis 76:948–959. https://doi.org/10.1136/annrheumdis-2016-210602 Omoumi P, Verdun FR, Guggenberger R, Andreisek G, Becce F (2015) Dual-energy CT: basic principles, technical approaches, and applications in musculoskeletal imaging (part 2). Semin Musculoskelet Radiol 19:438–445. https://doi.org/10.1055/s-0035-1569252 Nicolaou S, Liang T, Murphy DT, Korzan JR, Ouellette H, Munk P (2012) Dual-energy CT: a promising new technique for assessment of the musculoskeletal system. AJR Am J Roentgenol 199:S78-86. https://doi.org/10.2214/AJR.12.9117 Diekhoff T, Engelhard N, Fuchs M et al (2019) Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study. Eur Radiol 29:31–39. https://doi.org/10.1007/s00330-018-5568-y Ziegeler K, Hermann S, Hermann KGA, Hamm B, Diekhoff T (2020) Dual-energy CT in the differentiation of crystal depositions of the wrist: does it have added value? Skeletal Radiol 49:707–713. https://doi.org/10.1007/s00256-019-03343-5 Bongartz T, Glazebrook KN, Kavros SJ et al (2015) Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study. Ann Rheum Dis 74:1072–1077. https://doi.org/10.1136/annrheumdis-2013-205095 Kotlyarov M, Hermann KGA, Mews J, Hamm B, Diekhoff T (2021) Dual-energy computed tomography: tube current settings and detection of uric acid tophi. Eur J Radiol 139:109692. https://doi.org/10.1016/j.ejrad.2021.109692 Dossing A, Muller FC, Becce F, Stamp L, Bliddal H, Boesen M (2021) Dual-energy computed tomography for detection and characterization of monosodium urate, calcium pyrophosphate, and hydroxyapatite: a phantom study on diagnostic performance. Invest Radiol 56:417–424. https://doi.org/10.1097/RLI.0000000000000756 Tse JJ, Kondro DA, Kuczynski MT et al (2022) Assessing the sensitivity of dual-energy computed tomography 3-material decomposition for the detection of gout. Invest Radiol 57:613–619. https://doi.org/10.1097/RLI.0000000000000879