Improved image reconstruction from sensitivity-encoded data by wavelet denoising and Tikhonov regularization

Zhi-Pei Liang1, R. Bammer2, Jim Ji1, N.J. Pelc2, G.H. Glover2
1Department of Electrical and Computer Engineering, University of Illinois, Urbana-Champaign, USA
2Lucas Center for Magnetic Resonance Spectroscopy and Imaging, Stanford University School of Medicine, USA

Tóm tắt

Parallel magnetic resonance imaging through sensitivity encoding using multiple receiver coils has emerged as an effective tool to reduce imaging time. However, errors in both the estimated coil sensitivity maps and the measured data, and the ill-conditioned nature of the coefficient matrix (often associated with non-localized coils) can degrade image quality significantly, limiting speed enhancements. In this paper, we propose to use wavelet denoising to reduce noise in the coil sensitivity maps and a specially-designed Tikhonov regularization scheme to solve the ill-conditioned matrix equation. Experimental results show that these techniques produce significantly better images (with an improved signal-to-noise ratio and reduced aliasing artifacts) than conventional reconstruction methods based on matrix inversion with a diagonal regularization matrix.

Từ khóa

#Image reconstruction #Noise reduction #Coils #Magnetic resonance imaging #Encoding #Velocity measurement #Degradation #Image quality #Equations #Signal to noise ratio

Tài liệu tham khảo

king, 2001, SENSE image quality improvement using matrix regularization, Proc 9th Ann Meeting Intl Soc Mag Reson Med, 1771 katscher, 2001, Under-determined SENSE, Workshop on Minimum MR Data Acquisiion Methods Making More with Less, 42 keeling, 0, Variational based coil sensitivity estimation, Proc 9th Ann Meeting Intl Soc Mag Reson Med, 2001, 800 10.1109/18.382009 aldroubi, 1996, Wavelets in Medicine and Biology 10.2307/2337118 10.2307/2291512 ramchandran, 1999, Low-complexity image denoising based on statistical modeling of wavelet coefficients, EEE Signal Processing Letters, 6, 300, 10.1109/97.803428 kamick, 2001, SENSE geometry factor image processing, Proc 9th Ann Meeting Intl Soc Mag Reson Med, 1801 10.1002/mrm.1910300123 10.1118/1.596723 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S 10.1002/mrm.1910380414 10.1002/1522-2594(200008)44:2<301::AID-MRM18>3.0.CO;2-D 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO;2-5 kelton, 1989, An algorithm for rapid image acquisition using multiple receiver coils, Proc 8th Ann Meeting Soc Magn, 1172 10.1002/mrm.1910060110 10.1002/mrm.1241