High-Resolution Computed Tomography Examinations for Chronic Suppurative Lung Disease in Early Childhood: Radiation Exposure and Image Quality Evaluations with Iterative Reconstruction Algorithm Use

Canadian Association of Radiologists Journal - Tập 67 - Trang 218-224 - 2016
Magdalini Smarda1, Efstathios Efstathopoulos1, Argyro Mazioti1, Sofia Kordolaimi1, Agapi Ploussi1, Konstantinos Priftis2, Nikolaos Kelekis1, Efthymia Alexopoulou1
1Radiology Department, University General Hospital ATTIKON, Chaidari, Athens, Greece
2Department of Pediatrics, University General Hospital ATTIKON, Chaidari, Athens, Greece

Tóm tắt

Purpose High radiosensitivity of children undergoing repetitive computed tomography examinations necessitates the use of iterative reconstruction algorithms in order to achieve a significant radiation dose reduction. The goal of this study is to compare the iDose iterative reconstruction algorithm with filtered backprojection in terms of radiation exposure and image quality in 33 chest high-resolution computed tomography examinations performed in young children with chronic bronchitis. Methods Fourteen patients were scanned using the filtered backprojection protocol while 19 patients using the iDose protocol and reduced milliampere-seconds, both on a 64-detector row computed tomography scanner. The iDose group images were reconstructed with different iDose levels (2, 4, and 6). Radiation exposure quantities were estimated, while subjective and objective image qualities were evaluated. Unpaired t tests were used for data statistical analysis. Results The iDose application allowed significant effective dose reduction (about 80%). Subjective image quality evaluation showed satisfactory results even with iDose level 2, whereas it approached excellent image with iDose level 6. Subjective image noise was comparable between the 2 groups with the use of iDose level 4, while objective noise was comparable between filtered backprojection and iterative reconstruction level 6 images. Conclusions The iDose algorithm use in pediatric chest high-resolution computed tomography reduces radiation exposure without compromising image quality. Further evaluation with iterative reconstruction algorithms is needed in order to establish high-resolution computed tomography as the gold standard low-dose method for children suffering from chronic lung diseases.

Tài liệu tham khảo

Ogbole G.I., 2010, Ann Ib Postgrad Med, 8, 118 10.1136/bmj.f2360 10.1016/S0140-6736(12)60815-0 10.1148/radiol.2333031150 10.1148/radiol.2303021726 10.2214/AJR.09.2397 10.1148/radiol.12110268 10.1016/j.ejrad.2012.06.013 10.2214/AJR.13.10721 Kuczmarski R.J., 2002, Vital Health Stat, 11, 1 10.2214/AJR.13.11973 2007, Ann ICRP, 37, 1 Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations (Report #204) 2011 American Association of Physicists in Medicine College Park, MD 10.5694/j.1326-5377.2008.tb02085.x 10.1093/bmb/61.1.115 10.1136/adc.70.2.141 10.1148/radiol.10091487 10.1097/RCT.0b013e3181b26c67 10.1148/radiol.11101450