Hemodynamic Monitoring of Organ Donors: A Novel Use of the Esophageal Echo-Doppler Probe

American Surgeon - Tập 72 Số 6 - Trang 500-504 - 2006
James Cipolla1,2, Stanislaw P. Stawicki3, Deneen Spatz4
1St. Luke's Regional Trauma Center, Bethlehem, Pennsylvania;
2University of Pennsylvania Trauma Network, Philadelphia, Pennsylvania;
3Department of Surgery, St. Luke's Hospital and Health Network, Bethlehem, Pennsylvania; and
4Temple University School of Medicine, Philadelphia, Pennsylvania

Tóm tắt

The esophageal Doppler monitoring (EDM) technology is well described in the literature. As it evolved over the last several years, the use of EDM has found expanded indications in various clinical settings. One of the areas where EDM has not been studied extensively is its use during optimization of organ donors before organ procurement. Close hemodynamic monitoring has become essential in the era of increasing use of extended organ donors. We present six cases of successful EDM use during preorgan procurement resuscitation of organ donors. Despite labile hemodynamics in the majority of these cases, EDM-guided optimization of resuscitative end-points allowed successful organ procurements and transplants, including 12 kidneys, 6 livers, 3 hearts, 2 pancreases, and 2 lungs. The EDM technology is noninvasive, technically easy, and less expensive than the traditional pulmonary artery catheter. Other potential benefits of the EDM include its portability and possibility of deployment in any setting by trained organ procurement personnel or critical care nursing staff. In conclusion, successful organ procurement can be facilitated by the use of EDM technology in hemodynamically labile organ donor patients.

Từ khóa


Tài liệu tham khảo

United Network for Organ Sharing. United Network for Organ Sharing (UNOS) national data. All Donors by Donor Type, available at http://www.unos.org, Accessed November 2005.

United Network for Organ Sharing. United Network for Organ Sharing (UNOS) national data. All Donors by Donor Age, available at http://www.unos.org, Accessed November 2005.

10.1007/PL00012362

10.1034/j.1399-0012.17.s9.10.x

10.1097/01.TA.0000168708.78049.32

10.1016/S0039-6109(05)70111-0

10.7182/prtr.15.1.r748p5v35520036q

10.1016/S1053-2498(02)00380-7

Wheeldon D.R., 1995, J Heart Lung Transplant, 14, 734

10.1136/hrt.53.2.123

10.1067/mob.2000.106579

10.1097/01.ta.0000179955.12152.d4

Traub D., 2002, Crit Care Med Suppl, 30A63

10.1097/00005373-199904000-00008

10.1097/01.TA.0000105925.51950.08

Llau J.V., 1995, Rev Esp Anestesiol Reanim, 42, 51

10.1161/01.CIR.0000025587.40373.75

Saner F.H., 2004, Eur J Med Res, 9, 485

Pelosi G., 1986, Eur J Anaesthesiol, 3, 209

Squifflet J.P., 1986, Acta Anaesthesiol Belg, 37, 71

10.1097/00000542-200406000-00013

Centers for Disease Control and Prevention., 2002, Morbid Mortal Wkly Rep

10.1097/00003246-199308000-00008