Gold nanoparticles decorated carbon nanotube probe based immunochromatographic assay on cotton thread

Earthquake Spectra - Tập 251 - Trang 1112-1118 - 2017
Yan Liu1, Tingting Song1, Xiaobo Jia1, Lili Meng1, Xun Mao1
1Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, Shaanxi Province 710127, PR China

Tài liệu tham khảo

Chi, 2012, Nanoprobes for in vitro diagnostics of cancer and infectious diseases, Biomaterial, 33, 189, 10.1016/j.biomaterials.2011.09.032 Kumar, 2015, Graphene,carbon nanotubes, zinc oxide and gold as elite nanomaterials for fabrication of biosensors for healthcare, Biosens. Bioelectron., 70, 498, 10.1016/j.bios.2015.03.062 Kang, 2015, Diagnosis of prostate cancer via nanotechnological approach, Int. J. Nanomed., 10, 6555 Daniel, 2015, Nanoparticle-based lateral flow biosensors, Biosens. Bioelectron., 73, 47, 10.1016/j.bios.2015.05.050 Lijima, 1991, Helica micritubles of graphitic carbon, Nature, 354, 56, 10.1038/354056a0 Merkoçi, 2006, Carbon nanotubes in analytical sciences, Microchim. Acta, 152, 157, 10.1007/s00604-005-0439-z Justino, 2013, Advances in point-of-care technologies with biosensors based on carbon nanotubes, Trend Anal. Chem., 45, 24, 10.1016/j.trac.2012.12.012 Chu, 2010, Carbon nanotubes combined with inorganic nanomaterials: preparations and applications, Coordin. Chem. Rev., 257, 1117, 10.1016/j.ccr.2010.02.009 Yang, 2015, Carbon nanotube based biosensors, Sens. Actuator B, 207, 690, 10.1016/j.snb.2014.10.040 De Volder, 2013, Carbon nanotubes: present and future commercial applications, Science, 339, 535, 10.1126/science.1222453 Vashist, 2011, Delivery of drugs and biomolecules using carbon nanotubes, Carbon, 49, 4077, 10.1016/j.carbon.2011.05.049 Abera, 2010, Quantitative lateral flow immunosensor using carbon nanotubes as label, Anal. Methods, 2, 1819, 10.1039/c0ay00412j Meng, 2017, Novel immuochromatographic assay on cotton thread based on carbon nanotubes reporter probe, Talanta, 167, 379, 10.1016/j.talanta.2017.02.023 Mao, 2015, Disposable dry-reagent cotton thread-based point-of-care diagnosis devices for protein and nucleic acid test, Biosens. Bioelectron., 65, 390, 10.1016/j.bios.2014.10.053 Ballerini, 2011, Flow control concepts for thread-based microfluidic devices, Biomicrofluidics, 5, 1, 10.1063/1.3567094 Safavieh, 2011, Microfluidics made of yarns and knots: from fundamental properties to simple networks and operations, Lab Chip, 11, 2618, 10.1039/c1lc20336c Li, 2010, Thread as a versatile material for low-cost microfluidic diagnostics, ACS Appl. Mater. Interfaces, 2, 1, 10.1021/am9006148 Manori, 2014, Microfluidic paper-based analytical device for the determination of nitrite and nitrate, Anal. Chem., 86, 7274, 10.1021/ac5013249 Reches, 2010, Thread as a matrix for biomedical assays, ACS Appl. Mater. Interfaces, 2, 1722, 10.1021/am1002266 Nilghaz, 2013, Exploration of microfluidic devices based on multi-filament threads and textiles: a review, Biomicrofluidics, 7, 051501, 10.1063/1.4820413 Ballerini, 2012, Patterned paper and alternative materials as substrates for low-cost microfluidic diagnostics, Microfluid. Nanofluid., 13, 769, 10.1007/s10404-012-0999-2 Karlos, 2014, Recent advances in low-cost microfluidic platforms for diagnostic applications, Electrophoresis, 00, 1 Banerjee, 2013, Chemical synthesis and sensing in inexpensive thread-based microdevices, Sens. Actuator B, 186, 439, 10.1016/j.snb.2013.06.036 Zhou, 2012, Immunochromatographic assay on thread, Anal. Chem., 84, 7736, 10.1021/ac301082d Mao, 2015, Novel gold nanoparticle trimer reporter probe combined with dry-reagent cotton thread immunoassay device for rapid human ferritin test, Anal. Chim. Acta, 889, 172, 10.1016/j.aca.2015.06.031 Hong, 2012, Quantitative lateral-flow immunoassay for the assessment of the cartilage oligomeric matrix protein as a marker of osteoarthritis, Bio Chip, 6, 213 Posthuma-Trumpie, 2009, Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey, Anal. Bioanal. Chem., 393, 569, 10.1007/s00216-008-2287-2 Bahadır, 2016, Lateral flow assays: principles, designs and labels, Trends Anal. Chem., 82, 286, 10.1016/j.trac.2016.06.006 Sajid, 2015, Designs, formats and applications of lateral flow assay: a literature review, J. Saudi Chem. Soc., 19, 689, 10.1016/j.jscs.2014.09.001 Lai, 2009, Dual signal amplification of glucose oxidase- functionalized nanocomposites as a trace label for ultrasensitive simultaneous multiplexed electrochemical detection of tumor markers, Anal. Chem., 81, 9730, 10.1021/ac901996a Feng, 2015, Simultaneous electrochemical detection of multiple biomarkers using gold nanoparticles decorated multiwall carbon nanotubes as signal enhancers, Anal. Biochem., 482, 48, 10.1016/j.ab.2015.04.018 Shim, 2008, Smart electronic yarns and wearable fabrics for human biomonitoring made by carbon nanotube coating with polyelectrolytes, Nano Lett., 8, 4151, 10.1021/nl801495p