Fatigue performance of angle-stable tibial nail interlocking screws
Tóm tắt
Tibial nail interlocking screw failure often occurs during delayed fracture consolidation or at early weight bearing of nailed unstable fractures, in general when high implant stress could not be reduced by other means. Is there a biomechanical improvement in long-term performance of angle stable locking screws compared to conventional locking screws for distal locking of intramedullary tibial nails? Surrogate bones of human tibiae were cut in the distal third and distal locking of the 10 mm intramedullary tibial nail was performed with either two angle stable locking screws or two conventional locking screws in the mediolateral plane. Six specimens per group were mechanically tested under quasi-static and cyclic axial loading with constantly increasing force. Angle stable locking screw constructs exhibited significantly higher stiffness values (7,809 N/mm ± 647, mean ± SD) than conventional locking screw constructs (6,614 N/mm ± 859, p = 0.025). Angle stable locking screw constructs provided a longer fatigue life, expressed in a significantly higher number of cycles to failure (187,200 ± 18,100) compared to conventional locking screw constructs (128,700 ± 7,000, p = 0.004). Fatigue performance of locking screws can be ameliorated by the use of angle stable locking screws, being especially important if the nail acts as load carrier and an improved stability during fracture healing is needed.
Tài liệu tham khảo
Bhandari M, Guyatt GH, Swiontkowski MF, Schemitsch EH (2001) Treatment of open fractures of the shaft of the tibia. J Bone Joint Surg Br 83(1):62–68
Guo JJ, Tang N, Yang HL, Tang TS (2010) A prospective, randomised trial comparing closed intramedullary nailing with percutaneous plating in the treatment of distal metaphyseal fractures of the tibia. J Bone Joint Surg Br 92(7):984–988. doi:10.1302/0301-620X.92B7.22959
Whittle AP, Wester W, Russell TA (1995) Fatigue failure in small diameter tibial nails. Clin Orthop Relat Res 315:119–128
Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84(8):1093–1110
Im GI, Tae SK (2005) Distal metaphyseal fractures of tibia: a prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation. J Trauma 59(5):1219–1223, discussion 1223
Mohammed A, Saravanan R, Zammit J, King R (2008) Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture non-union. Int Orthop 32(4):547–549. doi:10.1007/s00264-007-0356-3
Bilat C, Leutenegger A, Ruedi T (1994) Osteosynthesis of 245 tibial shaft fractures: early and late complications. Injury 25(6):349–358
Court-Brown CM, McBirnie J (1995) The epidemiology of tibial fractures. J Bone Joint Surg Br 77(3):417–421
Forster MC, Bruce AS, Aster AS (2005) Should the tibia be reamed when nailing? Injury 36(3):439–444. doi:10.1016/j.injury.2004.09.030
Frigg R (2001) Locking compression plate (LCP). An osteosynthesis plate based on the dynamic compression plate and the point contact fixator (PC-Fix). Injury 32(2):63–66
Hasenboehler E, Rikli D, Babst R (2007) Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients. Injury 38(3):365–370. doi:10.1016/j.injury.2006.10.024
Gueorguiev B, Ockert B, Schwieger K, Wähnert D, Lawson-Smith M, Windolf M, Stoffel K (2011) Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study. J Orthop Trauma 25(6):340–346. doi:10.1097/BOT.0b013e3182163345
Gueorguiev B, Wähnert D, Albrecht D, Ockert B, Windolf M, Schwieger K (2011) Effect on dynamic mechanical stability and interfragmentary movement of angle-stable locking of intramedullary nails in unstable distal tibia fractures: a biomechanical study. J Trauma 70(2):358–365. doi:10.1097/TA.0b013e3181dbaaaf
Horn J, Linke B, Höntzsch D, Gueorguiev B, Schwieger K (2009) Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study. Injury 40(7):767–771. doi:10.1016/j.injury.2009.01.117
Weninger P, Schueller M, Jamek M, Stanzl-Tschegg S, Redl H, Tschegg EK (2009) Factors influencing interlocking screw failure in unreamed small diameter nails—a biomechanical study using a distal tibia fracture model. Clin Biomech (Bristol, Avon) 24(4):379–384. doi:10.1016/j.clinbiomech.2009.01.003
Windolf M, Muths R, Braunstein V, Gueorguiev B, Hänni M, Schwieger K (2009) Quantification of cancellous bone-compaction due to DHS blade insertion and influence upon cut-out resistance. Clin Biomech (Bristol, Avon) 24(1):53–58
Griffin LV, Harris RM, Zubak JJ (2009) Fatigue strength of common tibial intramedullary nail distal locking screws. J Orthop Surg Res 4:11. doi:10.1186/1749-799X-4-11
Kneifel T, Buckley R (1996) A comparison of one versus two distal locking screws in tibial fractures treated with unreamed tibial nails: a prospective randomized clinical trial. Injury 27(4):271–273
Boenisch UW, de Boer PG, Journeaux SF (1996) Unreamed intramedullary tibial nailing—fatigue of locking bolts. Injury 27(4):265–270
Perren SM, Fernandez Dell’Oca A, Lenz M, Windolf M (2011) Cerclage, evolution and potential of a Cinderella technology. An overview with reference to periprosthetic fractures. Acta Chir Orthop Traumatol Cech 78(3):190–199
Wähnert D, Stolarczyk Y, Hoffmeier KL, Raschke MJ, Hofmann GO, Mückley T (2012) The primary stability of angle-stable versus conventional locked intramedullary nails. Int Orthop 36(5):1059–1064. doi:10.1007/s00264-011-1420-6
Cole JD, Latta L (1992) Fatigue failure of interlocking tibial nail implant. J Orthop Trauma 6(4):507
Kinkel S, Wollmerstedt N, Kleinhans JA, Hendrich C, Heisel C (2009) Patient activity after total hip arthroplasty declines with advancing age. Clin Orthop Relat Res 467(8):2053–2058. doi:10.1007/s11999-009-0756-3
Winter CC, Brandes M, Müller C, Schubert T, Ringling M, Hillmann A, Rosenbaum D, Schulte TL (2010) Walking ability during daily life in patients with osteoarthritis of the knee or the hip and lumbar spinal stenosis: a cross sectional study. BMC Musculoskelet Disord 11:233. doi:10.1186/1471-2474-11-233
Kuhn H, Medlin D (eds) (2000) ASM handbook, volume 08: mechanical testing and evaluation. ASM International