Evaluating the accuracy of tooth color measurement by combining the Munsell color system and dental colorimeter

The Kaohsiung Journal of Medical Sciences - Tập 28 - Trang 490-494 - 2012
Jiun-Yao Chang1, Wen-Cheng Chen2, Ta-Ko Huang1, Jen-Chyan Wang1,3, Po-Sung Fu3, Jeng-Huey Chen1,3, Chun-Cheng Hung1,3
1School of Dentistry, Kaohsiung Medical University, 807 Kaohsiung, Taiwan
2Department of Fiber and Composite Materials, College of Engineering, Feng Chia University, Taichung 40724, Taiwan
3Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan

Tóm tắt

AbstractAs we pay increasing attention to dental aesthetics, tooth color matching has become an important part of daily dental practice. This aim of this study was to develop a method to enhance the accuracy of a tooth color matching machine. The Munsell color tabs in the range of natural human teeth were measured using a tooth color measuring machine (ShadeEye NCC). The machine's accuracy was analyzed using an analysis of variance test and a Tukey post‐hoc test. When matching the Munsell color tabs with the ShadeEye NCC colorimeter, settings of Chroma greater than 6 and Value less than 4 showed unacceptable clinical results. When the CIELAB mode was used, the a* value (which represents the red–green axis in the Commission Internationale de l'Eclairage color space) made no significant difference (p = 0.84), the L* value (which represents the lightness) resulted in a negative correlation, and the b* value (which represents the yellow–blue axis) resulted in a positive correlation with ΔE. When the Munsell color tabs and the Vitapan were measured in the same mode and compared, the inaccuracies showed that the Vitapan was not a proper tool for evaluating the stability and accuracy of ShadeEye NCC. By knowing the limitations of the machine, we evaluated the data using the Munsell color tabs; shade beyond the acceptable range should be reevaluated using a visual shade matching method, or if measured by another machine, this shade range should be covered to obtain more accurate results.

Tài liệu tham khảo

10.1016/S0022-3913(98)70049-6 10.1016/0022-3913(91)90209-F 10.1177/154405910208100815 Paul S.J., 2004, Conventional visual vs spectrophotometric shade taking for porcelain‐fused‐to‐metal crowns: a clinical comparison, Int J Periodontics Restorative Dent, 24, 222 10.1111/j.1708-8240.2003.tb00327.x 10.1177/00220345900690051101 10.1016/S0022-3913(08)60289-9 10.1111/j.1532-849X.2007.00163.x 10.1016/S0022-3913(09)60028-7 10.1016/0022-3913(73)90036-X 10.1177/00220345900690111001 10.1016/0022-3913(90)90038-E 10.1016/0022-3913(87)90380-5 10.1111/j.1520-6378.1994.tb00055.x 10.1111/j.1708-8240.1993.tb00771.x 10.1111/j.1520-6378.1979.tb00094.x 10.1016/S0109-5641(87)80081-7 10.1177/00220345890680051301 10.1016/S0109-5641(97)80121-2 10.1111/j.1708-8240.2003.tb00317.x 10.1016/j.jdent.2009.05.008 Hayashi T., 1967, Medical color standard. V. Tooth Crown Clark E.B., 1933, Tooth color selection, J Am Dent Assoc, 20, 1065 10.1177/00220345890680120701