Effect of a Stabilized Microbubble Contrast Agent on CW Ultrasound Induced Red Blood Cell Lysis In Vitro

Echocardiography - Tập 12 Số 1 - Trang 1-11 - 1995
Margaret W. Miller1, Mitra Azadniv1, Yukio Doida2, Andrew A. Brayman1
1Department of Biophysics, School of Medicine and Dentristry, The University of Rochester, Rochester, New York
2Department of Biology, Shiga University of Medical Science, Seta, Otsu, Shiga, Japan

Tóm tắt

Human red blood cells (RBCs) in vitro at various fractional hematocrits (HCTs) were exposed for 60–120 seconds in a dialysis tubing vessel to 1 MHz continuous wave ultrasound (0–5 W/cm2 SPTA intensity); exposure vessels were either rotated at 200 rpm or stationary. Some RBC suspensions also contained Albunex® (ALX; a commercially‐produced microbubble clinical ultrasound contrast agent) at final concentrations ranging from 0–41 μL/mL RBC suspension. Isonation was either by one transducer or by two opposing, continuously‐gated, balanced transducers. For the vessel rotation / no rotation experiments, ultrasound‐induced cell lysis was always increased with the ALX regimen relative to that of the no‐ALX regimen at HCTs up to about 10%; at higher HCTs (including whole blood), ultrasound‐induced hemol‐ysis essectially ceased to occur. The data are consistent with reports of the ineffectiveness of continuous wave ultrasound at 3–5 W/cm2 to lyse cells in vitro at physiological cell densities with or without echocontrast medium supplemantation.

Từ khóa


Tài liệu tham khảo

Albano G, 1971, Gas Nucleation Concepts Applied to Decompression in Underwater Physiology, 193

Chaussy C, 1986, Extra Corporeal Shock Wave Lithotripsy

10.1016/0301-5629(87)90075-5

10.1016/0301-5629(88)90025-7

10.1016/0301-5629(88)90178-0

10.1088/0031-9155/26/6/013

Haar G, 1982, Ultrasonically induced cavitation in vivo, Br J Cancer, 45, 151

10.1016/0301-5629(93)90126-9

10.1016/0301-5629(90)90046-F

10.1016/0301-5629(85)90011-0

10.1016/0301-5629(91)90124-F

10.1016/0301-5629(93)90007-B

Doida Y, 1992, Ultrasonically induced in vitro cell lysis: Node‐antinode interaction, J Ultrasound Med, 18, 413, 10.7863/jum.1992.11.8.413

10.1016/0301-5629(92)90049-G

Veress E, 1977, The haemolysing action of ultrasound on erythrocytes, Acustica, 36, 100

10.1016/0301-5629(88)90162-7

10.1016/0301-5629(92)90121-P

10.1016/0301-5629(93)90114-4

10.1007/BF00385933

10.1111/j.1540-8175.1991.tb01003.x

10.1121/1.1911940

Dunn F, 1977, A primary method for the determination of ultrasonic intensity with the elastic sphere radiometer, Acustica, 38, 58

10.1121/1.410302

10.1111/j.1540-8175.1992.tb00506.x

10.1259/0007-1285-58-694-989

10.1016/0301-5629(91)90125-G

10.1111/j.1540-8175.1995.tb00516.x