Dual mobility acetabular component in revision total hip arthroplasty for persistent dislocation: no dislocations in 50 hips after 1–5 years
Tóm tắt
Từ khóa
Tài liệu tham khảo
van der Grinten M, Verhaar JAN (2003) Dislocation of total hip prostheses: risk factors and treatment. Ned Tijdschr Gen 147:286–290
Khatod M, Barber T, Paxton E, Namba R, Fithian D (2006) An analysis of the risk of hip dislocation with a contemporary total joint registry. Clin Orthop Relat Res 447:19–23
Byström S, Espehaug B, Furnes O, Havelin LI (2003) Femoral head size is a risk factor for total hip luxation: a study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register. Acta Orthop Scand 74:514–524
Jolles BM, Zangger P, Leyvraz PF (2002) Factors predisposing to dislocation after primaru total hip arthroplasty: a multivariate analysis. J Arthroplasty 17:282–288
Alberton GM, High WA, Morrey BF (2002) Dislocation after revision total hip arthroplasty: an analysis of risk factors and treatment options. J Bone Joint Surg (Am) 84:1788–1792
Beaule PE, Schmalzried TP, Udomkiat P, Amstutz HC (2002) Jombo femoral head for the treatment of recurrent dislocation following total hip replacement. J Bone Joint Surg (Am) 84:256–263
Bosker BH, Ettema HB, Verheyen C, Castelein RM (2009) Acetabular augmentation ring for recurrent dislocation of total hip arthroplasty: 60% stability rate after an average follow-up of 74 months. Int Orthop 33(1):49–52
Williams JT Jr, Ragland PS, Clarke S (2007) Constrained components for the unstable hip following total hip arthroplasty: a literature overview. Int Orthop 31(3):273–277
Della Valle CJ, Chang D, Sporer S, Berger RA, Rosenberg AG, Paprosky WG (2005) High failure rate of a constrained acetabular liner in revision total hip arthroplasty. J Arthroplasty 20:103–107
Farizon F, de Lavison R, Azoulai JJ, Bousquet G (1998) Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. Int Orthop 22:219–224
Charnley J (1972) Long term results of low friction arthroplasty of hip as primary intervention. J Bone Joint Surg (Br) 54:61–76
McKee G, Farrar J (1966) Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg (Br) 48:245–259
Langlais FL, Ropars M, Gaucher F, Musset T, Chaix O (2008) Dual mobility cemented cups have low dislocation rates in THA revisions. Clin Orthop Relat Res 466:389–395
Götze C, Glosemeyer D, Ahrens J, Steens W, Gosheger G (2010) Die bipolare pfanne avantage in der hüftrevisionschirurgie. Z Orthop Unfall 148:420–425
Leiber-Wackenheim F, Brunschweiler B, Ehlinger M, Gabrion A, Mertl P (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years follow-up. Orthop Traumatol Surg Res 97:8–13
Civinini R, Carulli C, Matassi F, Nistri L, Innocenti M (2012) A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions. Clin Orthop Relat Res 470:3542–3548
Philippot R, Adam P, Reckhaus M, Delangle F, Verdot FX, Curval G, Farizon F (2009) Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res 95:407–413
Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation: 228 patients from the swedish hip arthroplasty Register. Acta Orthop 83:556–571
Massin P, Besnier L (2012) Acetabular revision using a press-fit dual mobility cup. Orthop Traumatol Surg Res 96:9–13
Guyen O, Pibarot V, Vaz G, Chevillotte C, Bejui-Hugues J (2009) Use of a dual mobility socket to manage total hip arthroplasty instability. Clin Orthop Relat Res 467:465–472
Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33:927–932
Bouchet R, Mercier N, Saragaglia D (2011) Posterior approach and dislocation rate: a 213 total hip replacements case–control study comparing the dual mobility cup with a conventional 28 mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res 97:2–7
Sanders RJ, Swierstra BA, Goosen JH (2013) The use of a dual mobility concept in total hip arthroplasty patients with spastic disorders. No dislocations in a series of ten cases at midterm follow-up. Arch Orthop Trauma Surg 133:1011–1016
Blom AW, Astle L, Loveridge J, Learmonth ID (2005) Revision of an acetabular liner has a high risk of dislocation. J Bone Joint Surg (Br) 87:1636–1638