Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study

Journal of Arthroplasty - Tập 30 - Trang 2204-2207 - 2015
Asheesh Gupta1, John M. Redmond1, Jon E. Hammarstedt1, Alexandra E. Petrakos1, S. Pavan Vemula1, Benjamin G. Domb1,2
1American Hip Institute, Westmont, Illinois
2Hinsdale Orthopaedics, Hinsdale, Illinois

Tài liệu tham khảo

Raphael, 2013, Obesity and operative time in primary total joint arthroplasty, J Knee Surg, 26, 95, 10.1055/s-0033-1333663

Haverkamp, 2011, Obesity in total hip arthroplasty—does it really matter? A meta-analysis, Acta Orthop, 82, 417, 10.3109/17453674.2011.588859

Chee, 2010, Total hip replacement in morbidly obese patients with osteoarthritis: results of a prospectively matched study, J Bone Joint Surg Br, 92, 1066, 10.1302/0301-620X.92B8.22764

Kelley, 1998, Relationship of femoral head and acetabular size to the prevalence of dislocation, Clin Orthop Relat Res, 355, 163, 10.1097/00003086-199810000-00017

Conroy, 2008, Risk factors for revision for early dislocation in total hip arthroplasty, J Arthroplast, 23, 867, 10.1016/j.arth.2007.07.009

Lewinnek, 1978, Dislocations after total hip-replacement arthroplasties, J Bone Joint Surg Am, 60, 217, 10.2106/00004623-197860020-00014

Callanan, 2011, The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital, Clin Orthop Relat Res, 469, 319, 10.1007/s11999-010-1487-1

Steppacher, 2011, Improving cup positioning using a mechanical navigation instrument, Clin Orthop Relat Res, 469, 423, 10.1007/s11999-010-1553-8

Domb, 2014, Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study, Clin Orthop Relat Res, 472, 329, 10.1007/s11999-013-3253-7

Elson, 2013, Are morbidly obese patients undergoing total hip arthroplasty at an increased risk for component malpositioning?, J Arthroplast, 28, 41, 10.1016/j.arth.2013.05.035

Wang, 2013, The increased utilization of operating room time in patients with increased BMI during primary total hip arthroplasty, J Arthroplast, 28, 680, 10.1016/j.arth.2012.06.037

Hohmann, 2011, A comparison between imageless navigated and manual freehand technique acetabular cup placement in total hip arthroplasty, J Arthroplast, 26, 1078, 10.1016/j.arth.2010.11.009

Lass, 2014, Total hip arthroplasty using imageless computer-assisted hip navigation: a prospective randomized study, J Arthroplast, 29, 786, 10.1016/j.arth.2013.08.020

Kalteis, 2006, Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?, J Bone Joint Surg Br, 88, 163, 10.1302/0301-620X.88B2.17163

Ryan, 2010, Accuracy of computer navigation for acetabular component placement in THA, Clin Orthop Relat Res, 468, 169, 10.1007/s11999-009-1003-7

Dorr, 2007, Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position, Clin Orthop Relat Res, 465, 92, 10.1097/BLO.0b013e3181560c51

Tsukada, 2010, Decreased accuracy of acetabular cup placement for imageless navigation in obese patients, J Orthop Sci, 15, 758, 10.1007/s00776-010-1546-1