Diaphragm and peripheral muscle thickness on ultrasound: Intra‐rater reliability and variability of a methodology using non‐standard recumbent positions

Respirology - Tập 16 Số 7 - Trang 1136-1143 - 2011
Claire Baldwin1,2, Jennifer Paratz3, Andrew D. Bersten1,2
1Faculty of Health Sciences, School of Medicine, Discipline of Critical Care Medicine, Flinders University
2Flinders Medical Centre, Intensive and Critical Care Unit, Bedford Park, South Australia
3Burns, Trauma and Critical Care Research Centre, University of Queensland/Royal Brisbane and Women's Hospital, Herston, Queensland, Australia

Tóm tắt

ABSTRACTBackground and objective:  Reliable measurement of diaphragm and peripheral muscle thickness, using diagnostic ultrasound, has only been validated in the erect posture. However, in many clinical populations, including critically ill patients, the erect posture presents logistic difficulties. This study aimed to validate ultrasound measurement of diaphragm and peripheral muscle thickness in the recumbent position.Methods:  An observational methodology of repeated but blind ultrasound and anthropometric measurements was applied, to assess inta‐rater reliability. Thirteen healthy volunteers (aged 20–73 years) participated. A pneumotachograph was used to target lung volume, as diaphragm thickness was measured from ultrasound at end‐expiration, and both 25% and 50% of inspiratory capacity, while semi‐recumbent. The thicknesses of the mid‐upper arm, mid‐forearm and mid‐thigh musculature were also measured bilaterally while supine.Results:  Diaphragm thickness could be reliably measured at end‐expiration (intra‐class correlation coefficient (ICC) = 0.990, 95% confidence interval: 0.918–0.998), 25% of inspiratory capacity (ICC = 0.959 (0.870–0.988)) and 50% of inspiratory capacity (ICC = 0.994 (0.980–0.998)). Peripheral muscle thickness measurements were also reliable (ICC = 0.998–1.0). Supine anthropometric measurements of limb segment lengths and girths were highly reproducible.Conclusions:  This ultrasound technique has good reliability in recumbent positions, making it useful for application to clinical populations when the erect posture is not practical.

Từ khóa


Tài liệu tham khảo

10.1183/09031936.97.10010059

10.1164/rccm.200802-232OC

Prentice CE, 2010, Differences in the degree of respiratory and peripheral muscle impairment are evident on clinical, electrophysiological and biopsy testing in critically ill adults: a qualitative systematic review, Crit. Care Resusc., 12, 111

10.1097/CCM.0b013e3181b6e760

10.1056/NEJMoa070447

10.1093/ajcn/62.3.533

10.1016/S0261-5614(03)00129-8

10.1164/rccm.2107031

10.1152/jappl.1989.67.4.1560

10.1136/thx.50.11.1157

10.1152/jappl.1997.83.1.291

Abu El‐Sameed Y, 2006, Ultrasound evaluation of diaphragm thickening and extubation outcome, Chest, 130, 201S

10.1007/BF01725734

Chen R, 2000, Twitch transdiaphragmatic pressure depends critically on thoracoabdominal configuration, J. Appl. Physiol., 88, 54, 10.1152/jappl.2000.88.1.54

10.1111/j.1469-7580.2006.00619.x

10.2340/16501977-0139

10.1016/S0022-510X(98)00134-8

10.1111/j.1475-097X.2009.00897.x

Acute Respiratory Distress Syndrome Network. 2 February 2005.Predicted body weight calculator. [Accessed 15 Sep 2010.] Available from URL:http://www.ardsnet.org/node/77460

10.1183/09041950.005s1693

10.1183/09031936.05.00034805

10.1164/ajrccm.155.4.9105075

10.1164/ajrccm.155.4.9105074

10.1177/0148607185009006712

Norton K, 1996, Anthropometrica: A Textbook of Body Measurement for Sports and Health Courses

10.1037/0033-2909.112.1.155

10.1002/(SICI)1097-0258(19980115)17:1<101::AID-SIM727>3.0.CO;2-E

10.3758/BF03193146

10.1378/chest.130.4_MeetingAbstracts.278S-c

10.1152/jappl.1987.62.5.1962

10.1097/01.CCM.0000229145.04482.93

10.1136/bjsm.18.3.149

10.1152/japplphysiol.00511.2003