Di-chromatic interpolation of magnetic resonance metabolic images
Tóm tắt
Từ khóa
Tài liệu tham khảo
Ardenkjær-Larsen JH, Fridlund B, Gram A, Hansson G, Hansson L, Lerche MH, Servin R, Thaning M, Golman K (2003) Increase in signal-to-noise ratio of $$> 10,000$$ times in liquid-state NMR. Proceedings of the National Academy of Sciences 100(18):10158–10163
Beck A, Teboulle M (2009) A fast iterative shrinkage-thresholding algorithm for linear inverse problems. SIAM journal on imaging sciences 2(1):183–202
Chambolle A, Pock T (2011) A first-order primal-dual algorithm for convex problems with applications to imaging. Journal of mathematical imaging and vision 40(1):120–145
Chen C, Li Y, Huang J (2013) Calibrationless parallel MRI with joint total variation regularization. In: International Conference on Medical Image Computing and Computer-Assisted Intervention, pp. 106–114. Springer
Chen HY, Larson PE, Gordon JW, Bok RA, Ferrone M, van Criekinge M, Carvajal L, Cao P, Pauly JM, Kerr AB et al (2018) Technique development of 3D dynamic CS-EPSI for hyperpolarized 13C pyruvate MR molecular imaging of human prostate cancer. Magnetic resonance in medicine 80(5):2062–2072
Cui X, Mili L, Wang G, Yu H (2018) Wavelet-based joint CT-MRI reconstruction. Journal of X-ray science and technology 26(3):379–393
Cunningham CH, Chen AP, Lustig M, Hargreaves BA, Lupo J, Xu D, Kurhanewicz J, Hurd RE, Pauly JM, Nelson SJ et al (2008) Pulse sequence for dynamic volumetric imaging of hyperpolarized metabolic products. Journal of magnetic resonance 193(1):139–146
Cunningham CH, Lau JY, Chen AP, Geraghty BJ, Perks WJ, Roifman I, Wright GA, Connelly KA (2016) Hyperpolarized 13C metabolic MRI of the human heart: initial experience. Circulation research 119(11):1177–1182
Das I (1999) On characterizing the “knee” of the pareto curve based on normal-boundary intersection. Structural optimization 18(2–3):107–115
Diamond S, Boyd S (2016) CVXPY: A python-embedded modeling language for convex optimization. The Journal of Machine Learning Research 17(1):2909–2913
Dwork N, Lasry EM, Pauly JM, Balbás J (2017) Formulation of image fusion as a constrained least squares optimization problem. Journal of Medical Imaging 4(1):014003
Ehman EC, Johnson GB, Villanueva-Meyer JE, Cha S, Leynes AP, Larson PEZ, Hope TA (2017) Pet/mri: where might it replace pet/ct? Journal of Magnetic Resonance Imaging 46(5):1247–1262
Ehrhardt MJ, Markiewicz P, Liljeroth M, Barnes A, Kolehmainen V, Duncan JS, Pizarro L, Atkinson D, Hutton BF, Ourselin S et al (2016) PET reconstruction with an anatomical MRI prior using parallel level sets. IEEE transactions on medical imaging 35(9):2189–2199
Esser E, Zhang X, Chan TF (2010) A general framework for a class of first order primal-dual algorithms for convex optimization in imaging science. SIAM Journal on Imaging Sciences 3(4):1015–1046
Fessler JA (2010) Model-based image reconstruction for MRI. IEEE signal processing magazine 27(4):81–89
Garzelli A (2016) A review of image fusion algorithms based on the super-resolution paradigm. Remote Sensing 8(10):797
Golman K, Petersson JS, Magnusson P, Johansson E, Åkeson P, Chai CM, Hansson G, Månsson S (2008) Cardiac metabolism measured noninvasively by hyperpolarized 13C MRI. Magnetic Resonance in Medicine: An Official Journal of the International Society for Magnetic Resonance in Medicine 59(5):1005–1013
Golman K, Thaning M et al (2006) Real-time metabolic imaging. Proceedings of the National Academy of Sciences 103(30):11270–11275
Gordon JW, Autry AW, Tang S, Graham JY, Bok RA, Zhu X, Villanueva-Meyer JE, Li Y, Ohilger MA, Abraham MR et al (2020) A variable resolution approach for improved acquisition of hyperpolarized 13C metabolic MRI. Magnetic Resonance in Medicine
Gordon JW, Vigneron DB, Larson PE (2017) Development of a symmetric echo planar imaging framework for clinical translation of rapid dynamic hyperpolarized 13C imaging. Magnetic resonance in medicine 77(2):826–832
Grant M, Boyd S (2008) Graph implementations for nonsmooth convex programs. In: Blondel V, Boyd S, Kimura H (eds.), Recent Advances in Learning and Control, Lecture Notes in Control and Information Sciences, pp. 95–110. Springer-Verlag Limited. http://stanford.edu/~boyd/graph_dcp.html. Accessed 6 Feb 2019
Grant M, Boyd S (2014) CVX: Matlab software for disciplined convex programming, version 2.1. http://cvxr.com/cvx. Accessed 6 Feb 2019
Grist JT, McLean MA, Riemer F, Schulte RF, Deen SS, Zaccagna F, Woitek R, Daniels CJ, Kaggie JD, Matys T et al (2019) Quantifying normal human brain metabolism using hyperpolarized [1-13C] pyruvate and magnetic resonance imaging. NeuroImage 189:171–179
Knoll F, Holler M, Koesters T, Otazo R, Bredies K, Sodickson DK (2016) Joint MR-PET reconstruction using a multi-channel image regularizer. IEEE transactions on medical imaging 36(1):1–16
Kurhanewicz J, Vigneron DB, Ardenkjaer-Larsen JH, Bankson JA, Brindle K, Cunningham CH, Gallagher FA, Keshari KR, Kjaer A, Laustsen C et al (2019) Hyperpolarized 13C MRI: path to clinical translation in oncology. Neoplasia 21(1):1–16
Larson PE, Chen HY, Gordon JW, Korn N, Maidens J, Arcak M, Tang S, Criekinge M, Carvajal L, Mammoli D et al (2018) Investigation of analysis methods for hyperpolarized 13C-pyruvate metabolic MRI in prostate cancer patients. NMR in Biomedicine 31(11):e3997
Larson PE, Hu S, Lustig M, Kerr AB, Nelson SJ, Kurhanewicz J, Pauly JM, Vigneron DB (2011) Fast dynamic 3D MR spectroscopic imaging with compressed sensing and multiband excitation pulses for hyperpolarized 13c studies. Magnetic resonance in medicine 65(3):610–619
Lau AZ, Chen AP, Hurd RE, Cunningham CH (2011) Spectral-spatial excitation for rapid imaging of DNP compounds. NMR in Biomedicine 24(8):988–996
Li Z, Leung H (2009) Fusion of multispectral and panchromatic images using a restoration-based method. IEEE transactions on geoscience and remote sensing 47(5):1482–1491
Liu J, Liu T, de Rochefort L, Ledoux J, Khalidov I, Chen W, Tsiouris AJ, Wisnieff C, Spincemaille P, Prince MR et al (2012) Morphology enabled dipole inversion for quantitative susceptibility mapping using structural consistency between the magnitude image and the susceptibility map. Neuroimage 59(3):2560–2568
Lukin A, Kubasov D (2004) High-quality algorithm for bayer pattern interpolation. Programming and Computer Software 30(6):347–358
Mehranian A, Belzunce MA, Prieto C, Hammers A, Reader AJ (2017) Synergistic PET and SENSE MR image reconstruction using joint sparsity regularization. IEEE transactions on medical imaging 37(1):20–34
Mugler JP III, Driehuys B, Brookeman JR, Cates GD, Berr SS, Bryant RG, Daniel TM, De Lange EE, Downs JH, Erickson CJ et al (1997) MR imaging and spectroscopy using hyperpolarized 129 Xe gas: preliminary human results. Magnetic resonance in medicine 37(6):809–815
Nelson SJ, Kurhanewicz J, Vigneron DB, Larson PE, Harzstark AL, Ferrone M, van Criekinge M, Chang JW, Bok R, Park I et al (2013) Metabolic imaging of patients with prostate cancer using hyperpolarized [1-13C] pyruvate. Science translational medicine 5(198):198ra108
Pock T, Cremers D, Bischof H, Chambolle A (2009) An algorithm for minimizing the mumford-shah functional. In: 2009 IEEE 12th International Conference on Computer Vision, pp. 1133–1140. IEEE
Rudin LI, Osher S, Fatemi E (1992) Nonlinear total variation based noise removal algorithms. Physica D: nonlinear phenomena 60(1–4):259–268
Scheinberg K, Goldfarb D, Bai X (2014) Fast first-order methods for composite convex optimization with backtracking. Foundations of Computational Mathematics 14(3):389–417
Schramm G, Holler M, Rezaei A, Vunckx K, Knoll F, Bredies K, Boada F, Nuyts J (2017) Evaluation of parallel level sets and bowsher’s method as segmentation-free anatomical priors for time-of-flight PET reconstruction. IEEE transactions on medical imaging 37(2):590–603
Schroeder MA, Clarke K, Neubauer S, Tyler DJ (2011) Hyperpolarized magnetic resonance: a novel technique for the in vivo assessment of cardiovascular disease. Circulation 124(14):1580–1594
Tang S, Milshteyn E, Reed G, Gordon J, Bok R, Zhu X, Zhu Z, Vigneron DB, Larson PE (2019) A regional bolus tracking and real-time B1 calibration method for hyperpolarized 13C MRI. Magnetic resonance in medicine 81(2):839–851
Wang Y, Cao N, Liu Z, Zhang Y (2017) Real-time dynamic MRI using parallel dictionary learning and dynamic total variation. Neurocomputing 238:410–419
Wang ZJ, Ohliger MA, Larson PE, Gordon JW, Bok RA, Slater J, Villanueva-Meyer JE, Hess CP, Kurhanewicz J, Vigneron DB (2019) Hyperpolarized 13c mri: State of the art and future directions. Radiology 291(2):273–284
Wu H, Zhao S, Zhang J, Lu C (2019) Remote sensing image sharpening by integrating multispectral image super-resolution and convolutional sparse representation fusion. IEEE Access 7:46562–46574