Development and Applications of Portable Biosensors

SLAS Technology - Tập 20 Số 4 - Trang 365-389 - 2015
Balaji Srinivasan1,2, Steve Tung1
1Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR, USA
2NanoScience Technology Center, University of Central Florida, Orlando, FL, USA

Tóm tắt

Từ khóa


Tài liệu tham khảo

Chatterjee, 2014

2014

2004

Lopez, 2005, The Evolution of the Global Burden of Disease Framework for Disease, Injury and Risk Factor Quantification: Developing the Evidence Base for National, Regional and Global Public Health Action, Global. Health., 1, 5, 10.1186/1744-8603-1-5

Yager, 2008, Point-of-Care Diagnostics for Global Health, Ann. Rev. Biomed. Engin., 10, 107, 10.1146/annurev.bioeng.10.061807.160524

Nezhad, 2014, Future of Portable Devices for Plant Pathogen Diagnosis, Lab Chip., 14, 2887, 10.1039/C4LC00487F

Mabey, 2004, Diagnostics for the Developing World, Nature Rev. Microbiol., 2, 231, 10.1038/nrmicro841

Ehrhart, 2008, A New Immunosensor for Breast Cancer Cell Detection Using Antibody-Coated Long Alkylsilane Self-Assembled Monolayers in a Parallel Plate Flow Chamber, Biosens. Bioelect., 24, 467, 10.1016/j.bios.2008.04.027

Mani, 2009, Ultrasensitive Immunosensor for Cancer Biomarker Proteins Using Gold Nanoparticle Film Electrodes and Multienzyme-Particle Amplification, ACS Nano., 3, 585, 10.1021/nn800863w

Kadir, 2010, Development of an Electrochemical Immunosensor for Fumonisins Detection in Foods, Toxins., 2, 382, 10.3390/toxins2040382

Jacobs, 2014, Antibody-Conjugated Gold Nanoparticle-Based Immunosensor for Ultra-Sensitive Detection of Troponin-T, JALA., 19, 546

Katrlik, 1999, Biosensors for L-Malate and L-Lactate Based on Solid Binding Matrix, Anal. Chim. Acta., 379, 193, 10.1016/S0003-2670(98)00610-2

Katrlik, 1998, Composite Alcohol Biosensors Based on Solid Binding Matrix, Biosens. Bioelect., 13, 181, 10.1016/S0956-5663(97)00104-8

Vidal, 2004, Amperometric Cholesterol Biosensors Based on the Electropolymerization of Pyrrole and the Electrocatalytic Effect of Prussian-Blue Layers Helped with Self-Assembled Monolayers, Talanta., 64, 655, 10.1016/j.talanta.2004.03.038

Wang, 1998, Polishable and Renewable DNA Hybridization Biosensors, Anal. Chem., 70, 3699, 10.1021/ac980092z

Tiwari, 2012, Detection of p53 Gene Point Mutation Using Sequence-Specific Molecularly Imprinted PoPD Electrode, Biosens. Bioelect., 35, 224, 10.1016/j.bios.2012.02.053

Wang, 2002, Electrochemical Nucleic Acid Biosensors, Anal. Chim. Acta., 469, 63, 10.1016/S0003-2670(01)01399-X

Banerjee, 2013, Biotoxin Detection Using Cell-Based Sensors, Toxins (Basel)., 5, 2366, 10.3390/toxins5122366

Mikkelsen, 2004

Homola, 2003, Present and Future of Surface Plasmon Resonance Biosensors, Anal. Bioanal. Chem., 377, 528, 10.1007/s00216-003-2101-0

Schofield, 1996, Determination of Affinities of a Panel of IgGs and Fabs for Whole Enveloped (Influenza A) Virions Using Surface Plasmon Resonance, J. Virol. Meth., 62, 33, 10.1016/0166-0934(96)02086-1

Boltovets, 2002, Simple Method for Plant Virus Detection: Effect of Antibody Immobilization Technique, J. Virol. Meth., 105, 141, 10.1016/S0166-0934(02)00098-8

Bizet, 1999, Biosensors Based on Piezoelectric Transducers, Analusis., 27, 609, 10.1051/analusis:1999270609

Cooper, 2001, Direct and Sensitive Detection of a Human Virus by Rupture Event Scanning, Nature Biotech., 19, 833, 10.1038/nbt0901-833

Gupta, 2004, Single Virus Particle Mass Detection Using Microresonators with Nanoscale Thickness, Appl. Phys. Lett., 84, 1976, 10.1063/1.1667011

Kauffmann, 1991, Potentiometric Enzyme Electrodes, Bioproc. Tech., 15, 63

Wang, 1999, Amperometric Biosensors for Clinical and Therapeutic Drug Monitoring: A Review, J. Pharm. Biomed. Anal., 19, 47, 10.1016/S0731-7085(98)00056-9

Ohnuki, 2007, Incorporation of Glucose Oxidase into Langmuir-Blodgett Films Based on Prussian Blue Applied to Amperometric Glucose Biosensor, Langmuir., 23, 4675, 10.1021/la063175g

Marzouk, 2007, Prototype Amperometric Biosensor for Sialic Acid Determination, Anal. Chem., 79, 1668, 10.1021/ac061886d

Yemini, 2007, Specific Electrochemical Phage Sensing for Bacillus cereus and Mycobacterium smegmatis, Bioelectrochemistry., 70, 180, 10.1016/j.bioelechem.2006.03.014

Pohanka, 2007, Biosensors for Biological Warfare Agent Detection, Defence Sci. J., 57, 185, 10.14429/dsj.57.1760

Liu, 2006, Biosensor Based on Self-Assembling Acetylcholinesterase on Carbon Nanotubes for Flow Injection/Amperometric Detection of Organophosphate Pesticides and Nerve Agents, Anal. Chem., 78, 835, 10.1021/ac051559q

Wang, 2010, Potentiometric Biosensor for Studying Hydroquinone Cytotoxicity In Vitro, Biosens. Bioelect., 25, 1356, 10.1016/j.bios.2009.10.027

Lum, 2012, Rapid Detection of Avian Influenza H5N1 Virus Using Impedance Measurement of Immuno-Reaction Coupled with RBC Amplification, Biosens. Bioelect., 38, 67, 10.1016/j.bios.2012.04.047

Wang, 2011, Evaluation Study of a Portable Impedance Biosensor for Detection of Avian Influenza Virus, J. Virol. Meth., 178, 52, 10.1016/j.jviromet.2011.08.011

Yang, 2005, AFM and Impedance Spectroscopy Characterization of the Immobilization of Antibodies on Indium–Tin Oxide Electrode through Self-Assembled Monolayer of Epoxysilane and Their Capture of Escherichia coli O157:H7, Biosens. Bioelect., 20, 1407, 10.1016/j.bios.2004.06.024

Yang, 2006, Detection of Viable Salmonella Using Microelectrode-Based Capacitance Measurement Coupled with Immunomagnetic Separation, J. Microbiol. Meth., 64, 9, 10.1016/j.mimet.2005.04.022

Suehiro, 1999, Quantitative Estimation of Biological Cell Concentration Suspended in Aqueous Medium by Using Dielectrophoretic Impedance Measurement Method, J. Phys. D Appl. Phys., 32, 2814, 10.1088/0022-3727/32/21/316

Thomas, 2004, Microbead-Based Electrochemical Immunoassay with Interdigitated Array Electrodes, Anal. Biochem., 328, 113, 10.1016/j.ab.2004.02.020

Antonelli, 2008, A Microcalorimetric Sensor for Food and Cosmetic Analyses: L-Malic Acid Determination, Talanta., 74, 1450, 10.1016/j.talanta.2007.09.035

2004

Ehrmeyer, 2007, Point-of-Care Testing, Medical Error, and Patient Safety: A 2007 Assessment, Clin. Chem. Lab. Med., 45, 766, 10.1515/CCLM.2007.164

Pai, 2012, Point-of-Care Testing for Infectious Diseases: Diversity, Complexity, and Barriers in Low- and Middle-Income Countries, PLoS Med., 9, e1001306, 10.1371/journal.pmed.1001306

The, 2011, Speed and Convenience Aren’t Everything with Diagnostics, PLoS Med., 8, e1001113, 10.1371/journal.pmed.1001113

St John, 2010, The Evidence to Support Point-of-Care Testing, Clin. Biochem., 31, 111

Cohen-Bacrie, 2011, Revolutionizing Clinical Microbiology Laboratory Organization in Hospitals with In Situ Point-of-Care, PLoS ONE., 6, e22403, 10.1371/journal.pone.0022403

Pai, 2008, Impact of Round-the-Clock, Rapid Oral Fluid HIV Testing of Women in Labor in Rural India, PLoS Med., 5, e92, 10.1371/journal.pmed.0050092

de Mello, 2003, Dealing with ‘Real’ Samples: Sample Pre-treatment in Microfluidic Systems, Lab Chip., 3, 11N, 10.1039/B301019H

Holliger, 2005, Engineered Antibody Fragments and the Rise of Single Domains, Nat. Biotechnol., 23, 1126, 10.1038/nbt1142

Bunyakul, 2009, Cholera Toxin Subunit B Detection in Microfluidic Devices, Anal. Bioanal. Chem., 393, 177, 10.1007/s00216-008-2364-6

James, 2010, High-Efficiency Magnetic Particle Focusing Using Dielectrophoresis and Magnetophoresis in a Microfluidic Device, J. Micromech. Microeng., 20, 045015, 10.1088/0960-1317/20/4/045015

Delehanty, 2002, A Microarray Immunoassay for Simultaneous Detection of Proteins and Bacteria, Anal. Chem., 74, 5681, 10.1021/ac025631l

Srinivasan, B., Varshney, M., Tung, S., et al. In A Microfluidic Filter Chip for Highly Sensitive Chemiluminescence Detection of E. coli O157:H7; ASME 2005 International Mechanical Engineering Congress and Exposition, American Society of Mechanical Engineers, 2005; pp. 43–48.

Varshney, 2007, A Label-Free, Microfluidics and Interdigitated Array Microelectrode-Based Impedance Biosensor in Combination with Nanoparticles Immunoseparation for Detection of Escherichia coli O157:H7 in Food Samples, Sens. Actuat. B Chem., 128, 99, 10.1016/j.snb.2007.03.045

Miranda, 2008, COLL 131: A Novel Gold Nanoparticle-Based Protein Sensor with Enzyme-Substrate Reactions as Signal Amplifiers, Abstr. Papers ACS., 236

Chen, 2010, A Novel Molecularly Imprinted Polymer Thin Film as Biosensor for Uric Acid, Talanta., 80, 1145, 10.1016/j.talanta.2009.08.041

Zhou, 2014, Aptamer-Based Biosensors for Biomedical Diagnostics, Analyst., 139, 2627, 10.1039/c4an00132j

Kulagina, 2005, Antimicrobial Peptides for Detection of Bacteria in Biosensor Assays, Anal. Chem., 77, 6504, 10.1021/ac050639r

Weng, 2011, Microfluidic DNA Hybridization Assays, Microfluid. Nanofluid., 11, 367, 10.1007/s10404-011-0858-6

Chen, 2008, DNA Hybridization Detection in a Microfluidic Channel Using Two Fluorescently Labelled Nucleic Acid Probes, Biosens. Bioelect., 23, 1878, 10.1016/j.bios.2008.02.013

Javanmard, 2011, A Microfluidic Platform for Electrical Detection of DNA hybridization, Sens. Actuat. B Chem., 154, 22, 10.1016/j.snb.2010.03.067

Malic, 2011, Designed Biointerface Using Near-Infrared Quantum Dots for Ultrasensitive Surface Plasmon Resonance Imaging Biosensors, Anal. Chem., 83, 5222, 10.1021/ac200465m

Demidov, 1994, Stability of Peptide Nucleic Acids in Human Serum and Cellular Extracts, Biochem. Pharmacol., 48, 1310, 10.1016/0006-2952(94)90171-6

Rane, 2012, Droplet Microfluidics for Amplification-Free Genetic Detection of Single Cells, Lab Chip., 12, 3341, 10.1039/c2lc40537g

Garibyan, 2013, Polymerase Chain Reaction, J. Invest. Dermatol., 133, e6, 10.1038/jid.2013.1

Zhang, 2007, Miniaturized PCR Chips for Nucleic Acid Amplification and Analysis: Latest Advances and Future Trends, Nucl. Acids Res., 35, 4223, 10.1093/nar/gkm389

Wang, 2011, Simultaneous Detection of Salmonella enterica, Escherichia coli O157:H7, and Listeria monocytogenes Using Oscillatory-Flow Multiplex PCR, Microchim. Acta., 173, 503, 10.1007/s00604-011-0584-5

Craw, 2012, Isothermal Nucleic Acid Amplification Technologies for Point-of-Care Diagnostics: A Critical Review, Lab Chip., 12, 2469, 10.1039/c2lc40100b

Dong, 2014, Development of a Loop-Mediated Isothermal Amplification Assay for Rapid, Sensitive Detection of Campylobacter jejuni in Cattle Farm Samples, J. Food. Prot., 77, 1593, 10.4315/0362-028X.JFP-14-056

Eckert, 2014, Molecular Test Based on Isothermal Helicase-Dependent Amplification for Detection of the Clostridium difficile Toxin A Gene, J. Clin. Microbiol., 52, 2386, 10.1128/JCM.00353-14

Niazi, 2013, A Nanodiagnostic Colorimetric Assay for 18S rRNA of Leishmania Pathogens using Nucleic Acid Sequence-Based Amplification and Gold Nanorods, Molec. Diag. Ther., 17, 363, 10.1007/s40291-013-0044-5

Boyle, 2014, Rapid Detection of Mycobacterium tuberculosis by Recombinase Polymerase Amplification, Plos ONE., 9, 10.1371/journal.pone.0103091

Pohl, 1978

Li, 2007, Continuous Dielectrophoretic Cell Separation Microfluidic Device, Lab Chip., 7, 239, 10.1039/B613344D

Park, 2011, Continuous Dielectrophoretic Bacterial Separation and Concentration from Physiological Media of High Conductivity, Lab Chip., 11, 2893, 10.1039/c1lc20307j

Moncada-Hernandez, 2010, Simultaneous Concentration and Separation of Microorganisms: Insulator-Based Dielectrophoretic Approach, Anal. Bioanal. Chem., 396, 1805, 10.1007/s00216-009-3422-4

Cheng, 2010, A Dielectrophoretic Chip with a Roughened Metal Surface for On-Chip Surface-Enhanced Raman Scattering Analysis of Bacteria, Biomicrofluidics., 4, 10.1063/1.3474638

Zeng, 2010, High-Performance Single Cell Genetic Analysis Using Microfluidic Emulsion Generator Arrays, Anal. Chem., 82, 3183, 10.1021/ac902683t

Wang, 2011, An Integrated Microfluidic Loop-Mediated-Isothermal-Amplification System for Rapid Sample Pre-treatment and Detection of Viruses, Biosens. Bioelect., 26, 2045, 10.1016/j.bios.2010.08.083

Mujika, 2009, Magnetoresistive Immunosensor for the Detection of Escherichia coli O157:H7 including a Microfluidic Network, Biosens. Bioelect., 24, 1253, 10.1016/j.bios.2008.07.024

Didar, 2010, Adhesion Based Detection, Sorting and Enrichment of Cells in Microfluidic Lab-on-Chip Devices, Lab Chip., 10, 3043, 10.1039/c0lc00130a

Li, 2011, A Nanobeads Amplified QCM Immunosensor for the Detection of Avian Influenza Virus H5N1, Biosens. Bioelect., 26, 4146, 10.1016/j.bios.2011.04.010

Srinivasan, B., Ju Seok, L., Hohnbaum, J., et al. In Performance Evaluation of a Pneumatic-Based Micromixer for Bioconjugation Reaction, Nano/Micro Engineered and Molecular Systems (NEMS), 2010 5th IEEE International Conference, 20–23 Jan 2010; pp. 810–814.

Wang, 2011, Evaluation Study of a Portable Impedance Biosensor for Detection of Avian Influenza Virus, J. Virol. Meth., 178, 52, 10.1016/j.jviromet.2011.08.011

Reichmuth, 2008, Rapid Microchip-Based Electrophoretic Immunoassays for the Detection of Swine Influenza Virus, Lab Chip., 8, 1319, 10.1039/b801396a

Kulinsky, 2013, Present Technology and Future Trends in Point-of-Care Microfluidic Diagnostics, 3

Mark, 2010, Microfluidic Lab-on-a-Chip Platforms: Requirements, Characteristics and Applications, Chem. Soc. Rev., 39, 1153, 10.1039/b820557b

West, 2008, Micro Total Analysis Systems: Latest Achievements, Anal. Chem., 80, 4403, 10.1021/ac800680j

Unger, 2000, Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography, Science (New York, N.Y.)., 288, 113, 10.1126/science.288.5463.113

Thorsen, 2002, Microfluidic Large-Scale Integration, Science (New York, N.Y.)., 298, 580, 10.1126/science.1076996

Schneider, 2013, The Potential Impact of Droplet Microfluidics in Biology, Anal. Chem., 85, 3476, 10.1021/ac400257c

Teh, 2008, Droplet Microfluidics, Lab Chip., 8, 198, 10.1039/b715524g

Srinivasan, 2004, An Integrated Digital Microfluidic Lab-on-a-Chip for Clinical Diagnostics on Human Physiological Fluids, Lab Chip., 4, 310, 10.1039/b403341h

Madou, 2006, Lab on a CD, Ann. Rev. Biomed. Engin., 8, 601, 10.1146/annurev.bioeng.8.061505.095758

Lee, 2011, Fully Integrated Lab-on-a-Disc for Simultaneous Analysis of Biochemistry and Immunoassay from Whole Blood, Lab Chip., 11, 70, 10.1039/C0LC00205D

Lee, 2011, Fully Integrated Lab-on-a-Disc for Simultaneous Analysis of Biochemistry and Immunoassay from Whole Blood, Lab Chip., 11, 70, 10.1039/C0LC00205D

Sandia National Laboratories. SpinDx. https://ip.sandia.gov/technology.do/techID=82 (accessed Nov 17, 2014).

Steigert, 2006, Direct Hemoglobin Measurement on a Centrifugal Microfluidic Platform for Point-of-Care Diagnostics, Sens. Actuat. A Phys., 130–131, 228, 10.1016/j.sna.2006.01.031

Yeo, 2009, Ultrafast Microfluidics Using Surface Acoustic Waves, Biomicrofluidics., 3, 10.1063/1.3056040

Wixforth, 2006, Acoustically Driven Programmable Microfluidics for Biological and Chemical Applications, JALA., 11, 399

Mens, 2008, Molecular Diagnosis of Malaria in the Field: Development of a Novel 1-Step Nucleic Acid Lateral Flow Immunoassay for the Detection of All 4 Human Plasmodium Spp. and Its Evaluation in Mbita, Kenya, Diag. Microbiol. Infect. Dis., 61, 421, 10.1016/j.diagmicrobio.2008.03.009

Assadollahi, 2009, From Lateral Flow Devices to a Novel Nano-Color Microfluidic Assay, Sensors., 9, 6084, 10.3390/s90806084

Rudolf Seitz, 1984, Immunoassay Labels Based on Chemiluminescence and Bioluminescence, Clin. Biochem., 17, 120, 10.1016/S0009-9120(84)90318-7

Chu, 2005, An Electrochemical Stripping Metalloimmunoassay Based on Silver-Enhanced Gold Nanoparticle Label, Biosens. Bioelect., 20, 1805, 10.1016/j.bios.2004.07.012

Yetisen, 2013, Paper-Based Microfluidic Point-of-Care Diagnostic Devices, Lab Chip., 13, 2210, 10.1039/c3lc50169h

Mao, 2012, Microfluidic Diagnostics for the Developing World, Lab Chip., 12, 1412, 10.1039/c2lc90022j

Chin, 2012, Commercialization of Microfluidic Point-of-Care Diagnostic Devices, Lab Chip., 12, 2118, 10.1039/c2lc21204h

Connelly, 1996, The Use of the iSTAT Portable Analyzer in Patients Undergoing Cardiopulmonary Bypass, J. Clin. Monitor., 12, 311, 10.1007/BF02221752

McNiven, 2012, Establishment of a Conversion Factor for the Cepheid GeneXpert BCR-ABL Assay, Pathology., 44, 55, 10.1097/PAT.0b013e32834e4203

Idaho Technology. FilmArray.

Cobas Liat System. http://molecular.roche.com/About/Pages/default.aspx (accessed Mar 27, 2015).

Fenton, 2005, Community Epidemiology Framework for Classifying Disease Threats, Emerg. Infect. Dis., 11, 1815, 10.3201/eid1112.050306

Binder, 1999, Emerging Infectious Diseases: Public Health Issues for the 21st Century, Science (New York, N.Y.)., 284, 1311, 10.1126/science.284.5418.1311

Meadows, 1996, Recent Developments with Biosensing Technology and Applications in the Pharmaceutical Industry, Adv. Drug Deliv. Rev., 21, 179, 10.1016/S0169-409X(96)00406-1

Guilbault, 2004, Biosensors—42 Years and Counting, Anal. Lett., 37, 1481, 10.1081/AL-120037582

Gong, 2003, An Amperometric Immunosensor for the Newcastle Disease Antibody Assay, Anal. Lett., 36, 287, 10.1081/AL-120017691

Wang, 2009, Interdigitated Array Microelectrode Based Impedance Immunosensor for Detection of Avian Influenza Virus H5N1, Talanta., 79, 159, 10.1016/j.talanta.2009.03.017

Liu, 2013, Rapid Evaluation of Salmonella pullorum Contamination in Chicken Based on a Portable Amperometric Sensor, J. Biosens. Bioelectron., 4, 2

Tang, 2004, Novel Potentiometric Immunosensor for Hepatitis B Surface Antigen Using a Gold Nanoparticle-Based Biomolecular Immobilization Method, Anal. Biochem., 333, 345, 10.1016/j.ab.2004.06.035

Kintzios, 2004, Study on the Mechanism of Bioelectric Recognition Assay: Evidence for Immobilized Cell Membrane Interactions with Viral Fragments, Biosens. Bioelect., 20, 907, 10.1016/j.bios.2004.04.009

Kintzios, 2001, Bioelectric Recognition Assay (BERA), Biosens. Bioelect., 16, 325, 10.1016/S0956-5663(01)00127-0

Lillie, 2001, Electrochemical Impedance Spectroscopy as a Platform for Reagentless Bioaffinity Sensing, Sens. Actuat. B Chem., 78, 249, 10.1016/S0925-4005(01)00821-8

Benhua, Z., Ronghui, W., Yixiang, W., et al. A Portable Impedance Biosensor for Detection of Multiple Avian Influenza Viruses, SENSORS, 2013 IEEE, 3–6 Nov 2013; pp. 1–4.

Katz, 2003, Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA-Sensors, and Enzyme Biosensors, Electroanalysis., 15, 913, 10.1002/elan.200390114

Ding, 2005, Impedance Spectral Studies of Self-Assembly of Alkanethiols with Different Chain Lengths Using Different Immobilization Strategies on Au Electrodes, Anal. Chim. Acta., 554, 43, 10.1016/j.aca.2005.08.046

Muhammad-Tahir, 2004, A Disposable Biosensor for Pathogen Detection in Fresh Produce Samples, Biosys. Engin., 88, 145, 10.1016/j.biosystemseng.2004.03.005

Muhammad-Tahir, 2005, Rapid Detection of Bovine Viral Diarrhea Virus as Surrogate of Bioterrorism Agents, Sensors J. IEEE., 5, 757, 10.1109/JSEN.2005.846377

Deo, 2004, Electrochemical Detection of Carbohydrates at Carbon-Nanotube Modified Glassy-Carbon Electrodes, Electrochem. Comm., 6, 284, 10.1016/j.elecom.2004.01.003

Susmel, 2003, Demonstration of Labeless Detection of Food Pathogens Using Electrochemical Redox Probe and Screen Printed Gold Electrodes, Biosens. Bioelect., 18, 881, 10.1016/S0956-5663(02)00214-2

Monk, 2004, Optical Fiber-Based Biosensors, Anal. Bioanal. Chem., 379, 931

Waswa, 2007, Direct Detection of E. coli O157:H7 in Selected Food Systems by a Surface Plasmon Resonance Biosensor, LWT – Food Sci. Tech., 40, 187, 10.1016/j.lwt.2005.11.001

Wei, 2007, Development of a Surface Plasmon Resonance Biosensor for the Identification of Campylobacter jejuni, J. Microbiol. Methods., 69, 78, 10.1016/j.mimet.2006.12.002

Gomara, 2000, Assessment of Synthetic Peptides for Hepatitis A Diagnosis Using Biosensor Technology, J. Immunol. Meth., 246, 13, 10.1016/S0022-1759(00)00295-7

Chen, 2005, Severe Acute Respiratory Syndrome Coronavirus 3C-Like Proteinase N Terminus is Indispensable for Proteolytic Activity but Not for Enzyme Dimerization: Biochemical and Thermodynamic Investigation in Conjunction with Molecular Dynamics Simulations, J. Biol. Chem., 280, 164, 10.1074/jbc.M408211200

Stefan, 2000, Immunosensors in Clinical Analysis, Fresenius J. Anal. Chem., 366, 659, 10.1007/s002160051560

Taitt, 2002, Nine-Analyte Detection Using an Array-Based Biosensor, Anal. Chem., 74, 6114, 10.1021/ac0260185

Renard, 2003, Deriving Topological Constraints from Functional Data for the Design of Reagentless Fluorescent Immunosensors, J. Molec. Biol., 326, 167, 10.1016/S0022-2836(02)01334-7

Ivnitski, 1999, Biosensors for Detection of Pathogenic Bacteria, Biosens. Bioelect., 14, 599, 10.1016/S0956-5663(99)00039-1

Rickert, 1996, A New Affinity Biosensor: Self-Assembled Thiols as Selective Monolayer Coatings of Quartz Crystal Microbalances, Biosens. Bioelect., 11, 591, 10.1016/0956-5663(96)83294-5

Zhou, 2002, Detection of Hepatitis B Virus by Piezoelectric Biosensor, J. Pharm. Biomed. Anal., 27, 341, 10.1016/S0731-7085(01)00538-6

Liu, 2004, Quartz Crystal Biosensor for Real-Time Kinetic Analysis of Interaction between Human TNF-α and Monoclonal Antibodies, Sens. Actuat. B Chem., 99, 416, 10.1016/j.snb.2003.12.010

Gubala, 2011, Point of Care Diagnostics: Status and Future, Anal. Chem., 84, 487, 10.1021/ac2030199

Wang, 2008, Electrochemical Glucose Biosensors, Chem. Rev., 108, 814, 10.1021/cr068123a

Luppa, 2011, Point-of-Care Testing (POCT): Current Techniques and Future Perspectives, Trends Anal. Chem., 30, 887, 10.1016/j.trac.2011.01.019

Ganter, 2008, Coagulation Monitoring: Current Techniques and Clinical Use of Viscoelastic Point-of-Care Coagulation Devices, Anesthes. Analges., 106, 1366, 10.1213/ane.0b013e318168b367

Dyszkiewicz-Korpanty, 2007, Clopidogrel Anti-Platelet Effect: An Evaluation by Optical Aggregometry, Impedance Aggregometry, and the Platelet Function Analyzer (PFA-100), Platelets., 18, 491, 10.1080/09537100701280654

Rapi, 2009, Point-of-Care Testing of Cholesterol and Triglycerides for Epidemiologic Studies: Evaluation of the Multicare-In System, Translat. Res., 153, 71, 10.1016/j.trsl.2008.11.010

Shephard, 2007, Comparative Performance of Two Point-of-Care Analysers for Lipid Testing, Clin. Lab., 53, 561

Sykes, 2005, Analytical Relationships among Biosite, Bayer, and Roche Methods for BNP and NT-proBNP: A Preliminary Study, Amer. J. Clin. Pathol., 123, 584, 10.1309/F86FVEFDGX06DTUV

Phillips, 2014, Rapid Point-of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms, Plos ONE., 9, 10.1371/journal.pone.0090226

Phillips, 2012, Point-of-Care Breath Test for Biomarkers of Active Pulmonary Tuberculosis, Tuberculosis., 92, 314, 10.1016/j.tube.2012.04.002

Nagaraj, 2010, NanoMonitor: A Miniature Electronic Biosensor for Glycan Biomarker Detection, Nanomedicine., 5, 369, 10.2217/nnm.10.11

OERKE, 2006, Crop Losses to Pests, J. Ag. Sci., 144, 31, 10.1017/S0021859605005708

Mansfield, 2012, Top 10 Plant Pathogenic Bacteria in Molecular Plant Pathology, Molec. Plant Pathol., 13, 614, 10.1111/j.1364-3703.2012.00804.x

Anderson, 2004, Emerging Infectious Diseases of Plants: Pathogen Pollution, Climate Change and Agrotechnology Drivers, Trends Ecol. Evol., 19, 535, 10.1016/j.tree.2004.07.021

Ward, 2004, Plant Pathogen Diagnostics: Immunological and Nucleic Acid-Based Approaches, Annals Appl. Biol., 145, 1, 10.1111/j.1744-7348.2004.tb00354.x

Kikuchi, 2009, A Rapid and Precise Diagnostic Method for Detecting the Pinewood Nematode Bursaphelenchus xylophilus by Loop-Mediated Isothermal Amplification, Phytopathology., 99, 1365, 10.1094/PHYTO-99-12-1365

McCartney, 2003, Molecular Diagnostics for Fungal Plant Pathogens, Pest Manage. Sci., 59, 129, 10.1002/ps.575

Schaad, 1999, Detection of Clavibacter michiganensis Subsp. sepedonicus in Potato Tubers by BIO-PCR and an Automated Real-Time Fluorescence Detection System, Plant Dis., 83, 1095, 10.1094/PDIS.1999.83.12.1095

Tomlinson, 2005, On-Site DNA Extraction and Real-Time PCR for Detection of Phytophthora ramorum in the Field, Appl. Environ. Microbiol., 71, 6702, 10.1128/AEM.71.11.6702-6710.2005

Sankaran, 2010, Review: A Review of Advanced Techniques for Detecting Plant Diseases, Comput. Electron. Agric., 72, 1, 10.1016/j.compag.2010.02.007

Belasque, 2008, Detection of Mechanical and Disease Stresses in Citrus Plants by Fluorescence Spectroscopy, Appl. Optics., 47, 1922, 10.1364/AO.47.001922

West, 2003, The Potential of Optical Canopy Measurement for Targeted Control of Field Crop Diseases, Ann. Rev. Phytopathol., 41, 593, 10.1146/annurev.phyto.41.121702.103726

Chaerle, 1999, Presymptomatic Visualization of Plant-Virus Interactions by Thermography, Nat. Biotech., 17, 813, 10.1038/11765

Narvankar, 2009, Assessment of Soft X-Ray Imaging for Detection of Fungal Infection in Wheat, Biosys. Engin., 103, 49, 10.1016/j.biosystemseng.2009.01.016

Zhang, 2007, Detection of Age and Insect Damage Incurred by Wheat, with an Electronic Nose, J. Stored Prod. Res., 43, 489, 10.1016/j.jspr.2007.01.004

Spinelli, 2004, Near Infrared Spectroscopy (NIRs): Perspective of Fire Blight Detection in Asymptomatic Plant Material, X International Workshop on Fire Blight, 704, 87

Imelfort, 2009, Discovering Genetic Polymorphisms in Next-Generation Sequencing Data, Plant Biotech. J., 7, 312, 10.1111/j.1467-7652.2009.00406.x

Kamboj, 2006, Biological Warfare Agents, Defence Sci. J., 56, 495, 10.14429/dsj.56.1915

Lim, 2005, Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare, Clin. Microbiol. Rev., 18, 583, 10.1128/CMR.18.4.583-607.2005

Palchetti, 2008, Electroanalytical Biosensors and Their Potential for Food Pathogen and Toxin Detection, Anal. Bioanal. Chem., 391, 455, 10.1007/s00216-008-1876-4

Caygill, 2010, A Review on Viral Biosensors to Detect Human Pathogens, Anal. Chim. Acta., 681, 8, 10.1016/j.aca.2010.09.038

Arora, 2011, Biosensors as Innovative Tools for the Detection of Food Borne Pathogens, Biosens. Bioelect., 28, 1, 10.1016/j.bios.2011.06.002

Edwards, 2006, Bacillus anthracis: Toxicology, Epidemiology and Current Rapid-Detection Methods, Anal. Bioanal. Chem., 384, 73, 10.1007/s00216-005-0090-x

Hao, 2011, DNA Probe Functionalized QCM Biosensor Based on Gold Nanoparticle Amplification for Bacillus anthracis Detection, Biosens. Bioelect., 26, 3398, 10.1016/j.bios.2011.01.010

Acharya, 2007, Label-Free Optical Detection of Anthrax-Causing Spores, J. Amer. Chem. Soc., 129, 732, 10.1021/ja0656649

Baeumner, 2004, A Rapid Biosensor for Viable B-Anthracis Spores, Anal. Bioanal. Chem., 380, 15, 10.1007/s00216-004-2726-7

Rider, 2003, A B Cell-Based Sensor for Rapid Identification of Pathogens, Science (New York, N.Y.)., 301, 213, 10.1126/science.1084920

Grate, 2010, Advances in Assays and Analytical Approaches for Botulinum-Toxin Detection, Trends Anal. Chem., 29, 1137, 10.1016/j.trac.2010.07.005

Ogert, 1992, Detection of Clostridium-Botulinum Toxin-A Using a Fiber Optica-Based Biosensor, Anal. Biochem., 205, 306, 10.1016/0003-2697(92)90440-I

Sun, 2009, Lab-on-a-Chip for Botulinum Neurotoxin A (BoNT-A) Activity Analysis, Lab Chip., 9, 3275, 10.1039/b912097a

Sapsford, 2008, A Fluorescence Detection Platform Using Spatial Electroluminescent Excitation for Measuring Botulinum Neurotoxin A Activity, Biosens. Bioelect., 24, 618, 10.1016/j.bios.2008.06.018

Ladd, 2008, Detection of Botulinum Neurotoxins in Buffer and Honey Using a Surface Plasmon Resonance (SPR) Sensor, Sens. Actuat. B Chem., 130, 129, 10.1016/j.snb.2007.07.140

Whitemarsh, 2012, Novel Application of Human Neurons Derived from Induced Pluripotent Stem Cells for Highly Sensitive Botulinum Neurotoxin Detection, Toxicol. Sci., 126, 426, 10.1093/toxsci/kfr354

Fernández-Salas, 2012, Botulinum Neurotoxin Serotype a Specific Cell-Based Potency Assay to Replace the Mouse Bioassay, PLoS ONE., 7, e49516, 10.1371/journal.pone.0049516

Pellett, 2013, Progress in Cell Based Assays for Botulinum Neurotoxin Detection, Curr. Topics Microbiol. Immunol., 364, 257

Wang, 2011, Detection of Staphylococcus aureus Carrying the Gene for Toxic Shock Syndrome Toxin 1 by Quantum-Dot-Probe Complexes, J. Fluoresc., 21, 1525, 10.1007/s10895-011-0840-4

Issadore, 2011, Miniature Magnetic Resonance System for Point-of-Care Diagnostics, Lab Chip., 11, 2282, 10.1039/c1lc20177h

Maraldo, 2007, Detection and Confirmation of Staphylococcal Enterotoxin B in Apple Juice and Milk Using Piezoelectric-Excited Millimeter-Sized Cantilever Sensors at 2.5 fg/mL, Anal. Chem., 79, 7636, 10.1021/ac070589l

Wojciechowski, 2010, Multiplexed Electrochemical Detection of Yersinia pestis and Staphylococcal Enterotoxin B Using an Antibody Microarray, Sensors., 10, 3351, 10.3390/s100403351

Huang, 2009, Sequential Detection of Salmonella typhimurium and Bacillus anthracis Spores Using Magnetoelastic Biosensors, Biosens. Bioelect., 24, 1730, 10.1016/j.bios.2008.09.006

Song, 2006, Fiber-Optic Microsphere-Based Arrays for Multiplexed Biological Warfare Agent Detection, Anal. Chem., 78, 1023, 10.1021/ac051417w

Preechaburana, 2014, Biosensing with Cell Phones, Trends Biotech., 32, 351, 10.1016/j.tibtech.2014.03.007

Mudanyali, 2012, Integrated Rapid-Diagnostic-Test Reader Platform on a Cellphone, Lab Chip., 12, 2678, 10.1039/c2lc40235a

Homola, 2008, Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species, Chem. Rev., 108, 462, 10.1021/cr068107d

Preechaburana, 2012, Surface Plasmon Resonance Chemical Sensing on Cell Phones, Angew. Chem. Intl. Ed., 51, 11585, 10.1002/anie.201206804

Rodionova, 2006, Chemometrics: Achievements and Prospects, Russian Chem. Rev., 75, 271, 10.1070/RC2006v075n04ABEH003599

Marini, 2009, Artificial Neural Networks in Foodstuff Analyses: Trends and Perspectives: A Review, Anal. Chim. Acta., 635, 121, 10.1016/j.aca.2009.01.009

Osma, 2014

Cetó, 2012, BioElectronic Tongue for the Quantification of Total Polyphenol Content in Wine, Talanta., 99, 544, 10.1016/j.talanta.2012.06.031

Smits, 1994, Using Artificial Neural Networks for Solving Chemical Problems. 1. Multilayer Feedforward Networks, Chemomet. Intel. Lab. Sys., 22, 165, 10.1016/0169-7439(93)E0035-3

Reder, 2003, Multi-Analyte Assay for Triazines Using Cross-Reactive Antibodies and Neural Networks, Biosens. Bioelect., 19, 447, 10.1016/S0956-5663(03)00202-1

Gutierrez, 2008, Bioelectronic Tongue for the Simultaneous Determination of Urea, Creatinine and Alkaline Ions in Clinical Samples, Biosens. Bioelect., 23, 795, 10.1016/j.bios.2007.08.019

Ferentinos, 2013, Pesticide Residue Screening Using a Novel Artificial Neural Network Combined with a Bioelectric Cellular Biosensor, BioMed Res. Intl., 2013, 8, 10.1155/2013/813519

Blick, 2001, The Essential Role of Information Management in Point-of-Care/Critical Care Testing, Clin. Chim. Acta., 307, 159, 10.1016/S0009-8981(01)00460-0

Nichols, 1999, Information Management for Point-of-Care Testing, Clin. Chem., 45, S36

Jacobs, 1995, The Satellite Laboratory and Point-of-Care Testing: Integration of Information, Amer. J. Clin. Pathol., 104, S33

St-Louis, 2000, Status of Point-of-Care Testing: Promise, Realities, and Possibilities, Clin. Biochem., 33, 427, 10.1016/S0009-9120(00)00138-7

Szelag, 2010, Point-of-Care Connectivity: The Connectivity Industry Consortium and Clinical and Laboratory Standards Institute Standard, 10 Years After, Point of Care., 9, 174, 10.1097/POC.0b013e3181ecca68

Price, 2007, Improving Healthcare Accessibility through Point-of-Care Technologies, Clin. Chem., 53, 1665, 10.1373/clinchem.2006.084707

Vasan, 2013, Point-of-Care Biosensor System, Frontiers Biosci. (Scholar ed.)., 5, 39, 10.2741/S357

Kakehi, 2007, A Novel Wireless Glucose Sensor Employing Direct Electron Transfer Principle Based Enzyme Fuel Cell, Biosens. Bioelect., 22, 2250, 10.1016/j.bios.2006.11.004

Ryou, 2011, An Implantable Wireless Biosensor for the Immediate Detection of Upper GI Bleeding: A New Fluorescein-Based Tool for Diagnosis and Surveillance (with Video), Gastrointest. Endosc., 74, 189, 10.1016/j.gie.2011.03.1182

Cai, 2014, A High Sensitivity Wireless Mass-Loading Surface Acoustic Wave DNA Biosensor, Mod. Phys. Lett. B, 28, 10.1142/S0217984914500560

Buratti, 2009, An Overview on Wireless Sensor Networks Technology and Evolution, Sensors., 9, 6869, 10.3390/s90906869

Schimke, 2009, Quality and Timeliness in Medical Laboratory Testing, Anal. Bioanal. Chem., 393, 1499, 10.1007/s00216-008-2349-5

American College of Medical Quality. http://www.acmq.org/policies/policies1and2.pdf (accessed Mar 27, 2015).

Fermann, 2002, Point of Care Testing in the Emergency Department, J. Emerg. Med., 22, 393, 10.1016/S0736-4679(02)00429-8

Muller, 1999, [Point-of-Care-Testing: The Intensive Care Laboratory], Anaesthesist., 48, 3, 10.1007/s001010050661

Nichols J. The National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Evidence-Based Practice for Point-of-Care Testing. https://www.aacc.org/research-and-recommendations/practice-guidelines/point-of-care-testing (accessed Nov 18, 2014).

International Organization of Standardization (2006) Point-of-Care Testing (POCT): Requirements for Quality and Competence. http://www.iso.org/iso/catalogue_detail.htm?csnumber=35173 (accessed Nov 18, 2014).