Decomposition of indwelling EMG signals

Journal of Applied Physiology - Tập 105 Số 2 - Trang 700-710 - 2008
S. Hamid Nawab1, Robert P. Wotiz, Carlo J. De Luca
1NeuroMuscular Research Center, Department of Electrical and Computer Engineering, Boston University, 8 St. Mary's St., Boston, MA 02215, USA.

Tóm tắt

Decomposition of indwelling electromyographic (EMG) signals is challenging in view of the complex and often unpredictable behaviors and interactions of the action potential trains of different motor units that constitute the indwelling EMG signal. These phenomena create a myriad of problem situations that a decomposition technique needs to address to attain completeness and accuracy levels required for various scientific and clinical applications. Starting with the maximum a posteriori probability classifier adapted from the original precision decomposition system (PD I) of LeFever and De Luca ( 25 , 26 ), an artificial intelligence approach has been used to develop a multiclassifier system (PD II) for addressing some of the experimentally identified problem situations. On a database of indwelling EMG signals reflecting such conditions, the fully automatic PD II system is found to achieve a decomposition accuracy of 86.0% despite the fact that its results include low-amplitude action potential trains that are not decomposable at all via systems such as PD I. Accuracy was established by comparing the decompositions of indwelling EMG signals obtained from two sensors. At the end of the automatic PD II decomposition procedure, the accuracy may be enhanced to nearly 100% via an interactive editor, a particularly significant fact for the previously indecomposable trains.

Từ khóa


Tài liệu tham khảo

10.1152/jn.00179.2003

10.1152/japplphysiol.01344.2004

10.1152/jn.1998.80.3.1373

Andreassen S. Computerized analysis of motor unit firing. Prog Clin Neurophysiol 10: 150–163, 1983.

Broman H. Knowledge-based signal processing in the decomposition of myoelectric signals. IEEE Eng Med Biol Mag 7/2: 24–28, 1988.

10.1109/7.53448

10.1109/10.740879

De Luca CJ, Forrest WJ. An electrode for recording single motor unit activity during strong muscle contractions. IEEE Trans Biomed Eng 19: 367–372, 1972.

10.1113/jphysiol.1982.sp014293

10.1113/jphysiol.1982.sp014294

De Luca CJ, Adam A. Decomposition and analysis of intramuscular electromyographic signals. In: Modern Techniques in Neuroscience Research, edited by Windhorst U, Johansson H. Heidelberg: Springer, 1999, p. 757–776.

10.1152/jn.00268.2006

10.1152/jn.1999.82.5.2081

Fang J, Agarwal GC, Shahani BT. Decomposition of EMG signal by wavelet spectrum matching. Proc 19th Ann Int Conf IEEE Eng Med Biol Soc, Chicago, IL, 1997, p. 1253–1256.

10.1109/TBME.2005.863893

10.1126/science.143.3612.1325

Glaser EM, Marks WB. The on-line separation of inter-leaved neuronal pulse sequences. Proc Rochester Conf Data Acquisition Biol Med, Rochester, NY, 1966, p. 137–156.

Guiheneuc P, Calamel J, Doncarli C, Gitton D, Michel C. Automatic detection and pattern recognition of single motor unit potentials in needle EMG. In: Computer-Aided Electromyography, edited by Desmedt JE. Basel: Karger, 1983, p. 73–127.

Hochstein L, Nawab SH, Wotiz R. An AI-based software architecture for a biomedical application. Proc 6th World Multiconf Systemics Cybernetics Informatics, Orlando, FL, 2002, p. 60–64.

10.1109/TSP.2007.896108

10.1016/0006-8993(89)90550-7

Keehn DG. An interactive spike separation technique. IEEE Trans Biomed Eng 13: 19–28, 1966.

10.1016/j.jelekin.2006.05.003

LeFever RS, De Luca CJ. Decomposition of action potential trains. Proc 8th Ann Meeting Soc Neurosci, St. Louis, MO, 1978, p. 229.

10.1109/TBME.1982.324881

10.1109/TBME.1982.324882

10.1016/0004-3702(94)00033-W

10.1007/BF02446790

10.1016/0013-4694(84)90031-2

Masakado Y, Akaboshi K, Nagata M, Kimura A, Chino N. Motor unit firing behavior in slow and fast contractions of the first dorsal interosseous muscle of healthy men. EEG Clin Neurophysiol 976: 290–295, 1995.

10.1016/1050-6411(91)90029-5

10.1109/TBME.1985.325562

10.1016/j.jneumeth.2005.05.015

Nawab SH, Lesser V. Integrated processing and understanding of signals. In: Symbolic and Knowledge Based Signal Processing, edited by Oppenheim AV, Nawab SH. Englewood Cliffs, NJ: Prentice-Hall, 1992, p. 251–285.

Nawab SH, Wotiz R, Hochstein L, De Luca CJ. Improved decomposition of intramuscular EMG signals. In: Proc 6th World Multiconf Systemics Cybernetics Informatics, Orlando, FL, 2002, p. 274–279.

Nawab SH, Wotiz R, Hochstein L, De Luca CJ. Next-generation decomposition of multi-channel EMG signals. Proc 2nd Joint Meeting IEEE Eng Med Biol Soc Biomed Eng Soc, Houston, TX, 2002, p. 36–37.

Nawab SH, Wotiz R, De Luca CJ. Resolving EMG pulse superpositions via utility maximization. Proc 8th World Multiconf Systemics Cybernetics Informatics, Orlando, FL, 2004, p. 233–236.

Nawab SH, Wotiz R, De Luca CJ. Improved resolution of pulse superpositions in a knowledge-based system for EMG decomposition. Proc 26th Int Conf IEEE Eng Med Biol Soc, San Francisco, CA, 2004, p. 69–71.

Nawab SH, Wotiz R, De Luca CJ. Multi-receiver precision decomposition of indwelling EMG signals. Proc 28th Int Conf IEEE Eng Med Biol Soc, New York, NY, 2006, p. 1252–1255.

10.1007/s11517-006-0051-3

10.1097/00005537-200212000-00014

10.1152/jn.00268.2006

10.1016/0013-4694(65)90029-5

10.1002/mus.880180305

10.1109/10.1330

10.1007/BF02637022

Von Neumann J, Morgenstern O. Theory of Games and Economic Behavior. Princeton, NJ: Princeton Univ. 1944.

10.1113/jphysiol.2004.076000

Winograd JM, Nawab SH. A C++ software environment for the development of embedded signal processing systems. Proc IEEE Int Conf Acoustics Speech Signal Processing, Detroit, MI, 1995, p. 2715–2718.

10.1109/7.18692

10.1109/TBME.2002.807321