Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging
Tóm tắt
The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals,P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0,P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X.
Tài liệu tham khảo
Epstein SE, Cannon RO III. Site of increased resistance to coronary flow in patients with angina pectoris and normal coronary arteries.J Am Coll Cardiol 1986; 8: 459–461.
Maseri A, Crea F, Kaski JC, Crake T. Mechanism of angina pectoris in syndrome X.J Am Coll Cardiol 1991; 17: 499–506.
Crea F, Pupita G, Galassi AR, et al. Role of adenosine in the pathogenesis of anginal pain.Circulation 1990; 81: 164–172.
Cianflone D, Lanza GA, Maseri A. Microvascular angina in patients with normal coronary arteries and with other ischemic syndromes.Eur Heart J 1995; 16: 96–103.
Montorsi P, Fabbiocchi F, Loaldi A, et al. Coronary adrenergic hyperreactivity in patients with syndrome X and abnormal electrocardiogram at rest.Am J Cardiol 1991, 68: 1698–1703.
Crake T, Canepa-Anson R, Shapiro L, Poole-Wilson PA. Continuous recording of coronary sinus oxygen saturation during atrial pacing in patients with coronary artery disease or with syndrome X.Br Heart J 1988; 59: 31–38.
Camici PG, Marraccini P, Lorenzoni R, et al. Coronary hemodynamics and myocardial metabolism in patients with syndrome X: response to pacing stress.J Am Coll Cardiol 1991; 17: 1461–1470.
Rosano GMC, Ponikowski P, Adamopoulos S, et al. Abnormal autonomic control of the cardiovascular system in syndrome X.Am J Cardiol 1994; 73: 1174–1179.
Quyyumi AA, Cannon RO, Panza JA, Diodati JG, Epstein SA. Endothelial dysfunction in patients with chest pain and normal coronary arteries.Circulation 1992; 86: 1864–1871.
Motz W, Vogt M, Rabenau O, Scheler S, Luckoff A, Strauer BE. Evidence of endothelial dysfunction in coronary resistance vessels in patients with angina pectoris and normal coronary angiogram.Am J Cardiol 1991; 68: 996–1003.
Egashira K, Inou T, Hirooka Y, Yamada A, Urabe Y, Takeshita A. Evidence of impaired endothelium-dependent coronary, vasodilatation in patients with angina pectoris and normal coronary angiogram.N Engl J Med 1993; 328: 1659–1664.
Vrints CJM, Bult H, Hitter E, Herman AG, Snoeck JP. Impaired endothelium dependent cholinergic coronary vasodilatation in patients with angina and normal coronary arteriograms.J Am Coll Cardiol 1992; 19: 21–31.
Yamagishi M, Miyatake K, Tamai J, Nakatani S, Koyama J, Nissen SE. Intravascular ultrasound detection of atherosclerosis at the site of focal spasm in angiographically normal or minimally narrowed coronary segments.J Am Coll Cardiol 1994; 23: 352–357.
Wiedermann JG, Schwatz A, Apfelbaum M. Anatomic and physiologic heterogeneity in patients with syndrome X: an intravascular ultrasound study.J Am Coll Cardiol 1995; 25: 1310–1317.
Mintz GS, Painter JA, Pichard AD, et al. Atherosclerosis in angiographically normal coronary artery reference segments: an intravascular ultrasound study with clinical correlations.J Am Coll Cardiol 1995; 25: 1479–1485.
Cannon RO, Epstein SE. “Microvascular angina” as a cause of chest pain with angiographically normal coronary arteries.Am J Cardiol 1988; 61: 1338–1343.
Opherk D, Zebe H, Weihe E, et al. Reduced coronary dilatory capacity and ultrastructural changes of the myocardium in patients with angina pectoris but normal coronary arteriograms. Circulation 1981; 63: 817–825.
Geltman EM, Henes G, Senneff MJ, Sobel BE, Bergmann SR. Increased myocardial perfusion at rest and diminished perfusion reserve in patients with angina and angiographically normal coronary arteries.J A Coll Cardiol 1990; 16: 586–595.
Camici PG, Gistri R, Lorenzoni R, et al. Coronary reserve and exercise EKG in patients with chest pain and normal coronary angiograms.Circulation 1992; 86: 179–186.
Zeiher AM, Drexler H, Wolfschlaeger H, Saurbier B, Just H. Coronary vasomotion in response to sympathetic stimulation in humans: importance of the functional integrity of the endothelium.Circulation 1991; 83: 391–401.
Vita JA, Treasure CB, Yeung AC, et al. Patients with evidence of coronary endothelial dysfunction as assessed by acetylcholine infusion demonstrate marked increase in sensitivity to constrictor effects of catecholamines.Circulation 1992; 85: 1390–1397.
Lefroy DC, Crake T, Uren NG, Davies GJ, Maseri A. Effect of nitric oxide synthesis on epicardial artery caliber and coronary blood flow in humans.Circulation 1993; 88: 43–54.
Nabel EG, Ganz P, Gordon JB, Alexander RW, Selwyn AP. Dilation of normal and constriction of atherosclerotic coronary arteries caused by the cold pressor stimulation.Circulation 1988; 77: 43–52.
Zeiher AM, Drexler H, Wollschlaeger H, Saurbier B, Just H. Coronary vasomotion in response to sympathetic stimulation in humans: importance of the functional integrity of the endothelium.J Am Coll Cardiol 1989; 14: 1181–1190.
Meeder JG, Peels HO, Blanksma PK, et al. Comparison between PET myocardial perfusion imaging and intracoronary Doppler-flow velocity measurements at rest and during cold pressor testing in angiographically normal coronary arteries in patients with single vessel coronary artery disease. Am J Cardiol 1996; 78: 526–531.
Schelbert HR, Phelps ME, Huang SC, et al. N-13 ammonia as an indicator of myocardial blood flow.Circulation 1981; 63: 1259–1272.
Wisenberg G, Schelbert HR, Hoffman EJ, et al. In vivo quantification of regional myocardial blood flow by PET.Circulation 1981; 63: 1248–1258.
Shah A, Schelbert HR, Schwaiger M, et al. Measurement of regional myocardial blood flow with N-13 ammonia and PET in intact dogs.J Am Coll Cardiol 1985; 5: 92–100.
Bellina CR, Parodi O, Camici P, et al. Simultaneous in vitro and in vivo validation of nitrogen-13-ammonia for the assessment of regional myocardial blood flow.J Nucl Med 1990; 31: 1335–1343.
Blanksma PK, Willemsen ATM, Meeder JG, et al. Quantitative myocardial mapping of perfusion and metabolism using parametric polar map displays in cardiac PET.J Nucl Med 1995; 35: 153–158.
Jong de RM, Blanksma PK, Willemsen ATM, et al. The “posterolateral defect” of the normal human heart investigated with nitrogen-13 ammonia and dynamic PET.J Nucl Med 1995; 36: 581–585.
Meeder JG, Blanksma PK, Crijns HJGM, et al. Mechanisms of angina pectoris in syndrome X assessed by myocardial perfusion dynamics and heart rate variability.Ear Heart J 1995; 16: 1571–1577.
Cannon RO, Schenke WH, Leon MB, Rosing DR, Urqhart J, Epstein SE. Limited coronary flow reserve after dipyridamole in patients with ergonovine-induced coronary vasoconstriction.Circulation 1987; 75: 163–174.
Galassi AR, Crea F, Araujo LL et al. Comparison of regional myocardial blood flow in syndrome X and one-vessel coronary artery disease.Am J Cardiol 1993; 72: 134–139.
Rosen SD, Uren NG, Kaski JC. Tousoulis D, Davies GJ, Camici PG. Coronary vasodilator reserve, pain perception and sex in patients with syndrome X.Circulation 1994; 90: 50–60.
Kaski JC, Tousoulis D, Galassi AR, et al. Epicardial coronary artery tone and reactivity in patients with normal coronary arteriograms and reduced coronary flow reserve.J Am Coll Cardiol 1991, 18: 50–54.
Bassingthewaithe JB, King RB, Roger SA. Fractal nature of regional myocardial blood flow heterogeneity.Circ Res 1989; 65: 578–590.
Visser KR, Meeder JG, Blanksma PK, Lie KI. A fractal model to investigate the influence of spatial resolution on estimation of myocardial blood flow heterogeneity as measured by N-13 ammonia PET [abstract]. European Conference on Cardiac PET Research 1995; Book of abstracts: 22.
Hutchins GD, Schwaiger M, Rosenpire KC, Krivokapich J, Schelbert HR. Non-invasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging.J Am Coll Cardiol 1990; 15: 1032–1042.
Krivokapich J, Smith GT, Huang SC, et al. N-13 ammonia myocardial imaging at rest and with exercise in normal volunteers: quantification of absolute myocardial perfusion with dynamic PET.Circulation 1989; 80: 1328–1337.
Meeder JG, Blanksma PK, van der Wall EE, et al. Long-term cigarette smoking is associated with increased myocardial perfusion heterogeneity assessed by PET.Ear J Nucl Med 1996; 23: 1442–1447.
Kern MJ, Horowitz JD, Ganz P, et al. Attenuation of coronary vascular resistance by alpha-adrenergic blockade in patients with coronary artery disease.J Am Coll Cardiol 1985; 5: 840–846.
Feigenbaum H. Clinical echocardiography. New York: Lea & Febiger. 1990.
Yoshida K, Endo M, Toshiharu H, et al. Measurement of regional blood flow in hypertrophic cardiomyopathy: application of the first pass flow model using N-13 ammonia and PET.Am J Physiol Imaging 1989; 4: 97–104.
Rosenspire KC, Schwaiger M, Mangner TJ, Hutchins GD, Sutoric A, Hukl DE. Metabolic fate of N-13 ammonia in human and canine blood.J Nucl Med 1990; 31: 165–166.