Comparison of magnetic fields emitted from security screening devices with magnetic field immunity standards

J.P. Casamento1
1Center for Devices and Radiological Health, U.S. Food and Drug Administration, Rockville, MD, USA

Tóm tắt

The Food and Drug Administration (FDA) received over 90 problem reports of medical device malfunctions due to electromagnetic interference (EMI) from magnetic field emitting security devices. The FDA took action to alert users and manufacturers of medical devices and security screening devices. These malfunctions were thought to be related to the electromagnetic fields emitted from the security device and judged serious enough by the reporters (clinical users of these devices) to potentially cause patient injuries. Measurements of magnetic field emissions from security devices reveal that some security screening devices can emit magnetic fields at strengths that exceed the test levels specified in some medical device standards.

Từ khóa

#Magnetic fields #Security #Magnetic field measurement #Electromagnetic interference #Immune system #Drugs #Food manufacturing #Electromagnetic fields #Injuries #Electromagnetic measurements

Tài liệu tham khảo

0, Active Implantable Medical Devices Part 2-2: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (Includes implantable defibrillators), CENELEC prEN 45502 (1998) 0, Safety of implantable cardiac pacemakers, CENELEC EN 50061/A 1 (1995) 0, Implants for surgery – Active implantable medical devices – Part 1: General requirements for safety, marking and for information to be provided by the manufacturer, ISO 14708-1 (2000) 0, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment, MIL-STD-461E (1999) 10.1109/10.983460 neubauer, 1998, Measurements and Safety Evaluation of Electromagnetic Fields near Article Surveillance Systems 10.1161/01.CIR.100.4.387 lewis, 0, teraction between Electronic Article Surveillance Systems and Implantable Defibrillators: Insights from a Fourth Generation ICD, PAC 1997, 20, 2857 wolfgang, 0, Electromagnetic Compatibility of Electronic Implants Review of the Literature, Weiner Klin Wochenschr(2001) 113/23 (the Middle European Journal of Medicine), 903 casamento, 1999, Characterizing Electromagnetic Fields Of Common Electronic Article Surveillance Systems, Compliance Engineering September/October, 42 ivor, 0, Environmental Electromagnetic Interference from Electronic Article Surveillance devices: Interactions with an ICD, PACE 1995, 18, 2229 2000, Labeling for Electronic Anti-Theft Systems, FDA Advisory U S Food and Drug Administration Center for Devices and Radiological Health 1998, Important Information on Anti-Theft and Metal Detector Systems and Pacemakers, ICDs, and Spinal Cord Stimulators, FDA Advisory U S Food and Drug Administration Center for Devices and Radio Administration Center for Devices and Radiological Health witters, 2000, Examining Potential EMI Between Medical Devices and Electronic Security Systems, Medical Device Diagnostic Industry, 196 silberberg, 1996, Electronic Medical Devices and EMI, Compliance Engineering, -14d 0, Active Implantable Medical Devices Part 2-1: Particular requirements for active implantable medical devices intended to treat bradyarrhythmia (cardiac pacemakers), CENELEC Draft prEN 45502 (2000)