Comparison of an 8-Channel and a 32-Channel Coil for High-Resolution fMRI at 7 T

Brain Topography - Tập 27 - Trang 209-212 - 2013
Roy Salomon1,2, Jana Darulova1,3, Mayur Narsude3, Wietske van der Zwaag3
1Laboratory of Cognitive Neuroscience (LNCO), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
2Center for Neuroprosthetics, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
3Laboratory for Functional and Metabolic Imaging (LIFMET), CIBM-AIT, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland

Tóm tắt

Multi-channel receive array rf-coils have become widely available for fMRI. The improved SNR and possibility of acquisition acceleration through parallel imaging are especially beneficial for high-resolution studies. In this study, an 8-channel and a 32-channel coil were compared in a high-resolution finger tapping fMRI experiment at 7 T. 1.3 mm3 resolution data acquired with the 32-channel coil provided higher image- and temporal SNR and yielded higher BOLD sensitivity measures, notably higher cluster sizes in MI/SI and increased z-scores, though not an increase in percent signal change. For sub-millimeter resolution fMRI data acquired with the 32-channel coil smaller clusters were found, though percent signal changes were significantly larger, due to reduced partial volume effects. These results demonstrate the utility of the use of an array coil with a large number of receive elements for high-resolution fMRI at ultra-high field.

Tài liệu tham khảo

Bianciardi M, van Gelderen P, Duyn JH, Fukunaga M, de Zwart JA (2009) Making the most of fMRI at 7 T by suppressing spontaneous signal fluctuations. NeuroImage 44(2):448–454 Bodurka J, Ye F, Petridou N, Murphy K, Bandettini PA (2007) Mapping the MRI voxel volume in which thermal noise matches physiological noise—implications for fMRI. NeuroImage 34(2):542–549 Kaza E, Klose U, Lotze M (2011) Comparison of a 32-channel with a 12-channel head coil: are there relevant improvements for functional imaging? J Magn Reson Imaging 34(1):173–183 Lai S, Glover GH (1998) Three-dimensional spiral fMRI technique: a comparison with 2D spiral acquisition. Magn Reson Med 39(1):68–78 Mekle R, van der Zwaag W, Joosten A, Gruetter R (2008) Comparison of three commercially available radio frequency coils for human brain imaging at 3 T. Magma 21(1–2):53–61 van der Zwaag W, Marques JP, Hergt M, Gruetter R (2009) Investigation of high-resolution functional magnetic resonance imaging by means of surface and array radiofrequency coils at 7 T. Magn Reson Imaging 27(8):1011–1018 Wiggins GC, Triantafyllou C, Potthast A, Reykowski A, Nittka M, Wald LL (2006) 32-channel 3 T receive-only phased-array head coil with soccer-ball element geometry. Magn Reson Med 56(1):216–223