Comparison of 1-Ethyl-3-(3-Dimethylaminopropyl) Carbodiimide Based Strategies to Crosslink Antibodies on Amine-Functionalized Platforms for Immunodiagnostic Applications
Tóm tắt
1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) alone, and in combination with N-hydroxysuccinimide (NHS) or sulfoNHS were employed for crosslinking anti-human fetuin A (HFA) antibodies on 3-aminopropyltriethoxysilane (APTES)-functionalized surface plasmon resonance (SPR) gold chip and 96-well microtiter plate. The SPR immunoassay and sandwich enzyme linked immunosorbent immunoassay (ELISA) for HFA clearly demonstrated that EDC crosslinks anti-HFA antibodies to APTES-functionalized bioanalytical platforms more efficiently than EDC/NHS and EDC/sulfoNHS at a normal pH of 7.4. Similar results were obtained by sandwich ELISAs for human Lipocalin-2 and human albumin, and direct ELISA for horseradish peroxidase. The more efficient crosslinking of antibodies by EDC to the APTES-functionalized platforms increased the cost-effectiveness and analytical performance of our immunoassays. This study will be of wide interest to researchers developing immunoassays on APTES-functionalized platforms that are being widely used in biomedical diagnostics, biosensors, lab-on-a-chip and point-of-care-devices. It stresses a critical need of an intensive investigation into the mechanisms of EDC-based amine-carboxyl coupling under various experimental conditions.
Từ khóa
Tài liệu tham khảo
Vashist, 2011, Effect of antibody immobilization strategies on the analytical performance of a surface plasmon resonance-based immunoassay, Analyst, 136, 4431, 10.1039/c1an15325k
Jung, 2008, Recent advances in immobilization methods of antibodies on solid supports, Analyst, 133, 697, 10.1039/b800014j
Wong, 2009, Selective covalent protein immobilization: Strategies and applications, Chem. Rev., 109, 4025, 10.1021/cr8004668
Hahn, 2008, Current advances in antibody immobilization on different surfaces and beads, Curr. Proteom., 5, 115, 10.2174/157016408784911918
Hermanson, G.T. (2008). BioconjugateTechniques, Academic Press. [2nd].
Teste, 2010, A chemometric approach for optimizing protein covalent immobilization on magnetic core-shell nanoparticles in view of an alternative immunoassay, Talanta, 81, 1703, 10.1016/j.talanta.2010.03.027
Ramanaviciene, 2010, Comparative study of random and oriented antibody immobilization techniques on the binding capacity of immunosensors, Anal. Chem., 82, 6401, 10.1021/ac100468k
Lee, 2011, Highly reproducible immunoassay of cancer markers on a gold-patterned microarray chip using surface-enhanced Raman scattering imaging, Biosens. Bioelectron., 26, 2135, 10.1016/j.bios.2010.09.021
Zhang, 2011, A rapid and sensitive chemiluminescence immunoassay based on magnetic particles for squamous cell carcinoma antigen in human serum, Clin. Chim. Acta, 412, 1572, 10.1016/j.cca.2011.05.005
Jang, 2006, In situ electrochemical enzyme immunoassay on a microchip with surface-functionalized poly(dimethylsiloxane) channel, Enzym. Microb. Technol., 39, 1122, 10.1016/j.enzmictec.2006.02.020
Lee, 2007, Microfluidic systems integrated with two-dimensional surface plasmon resonance phase imaging systems for microarray immunoassay, Biosens. Bioelectron., 23, 466, 10.1016/j.bios.2007.05.007
Song, 2011, A fluoro-microbead guiding chip for simple and quantifiable immunoassay of cardiac troponin I (cTnI), Biosens. Bioelectron., 26, 3818, 10.1016/j.bios.2011.02.036
Dixit, 2011, Multi-substrate compatible ELISA procedures for rapid and high sensitivity immunoassays, Nat. Protoc., 6, 439, 10.1038/nprot.2011.304
Dixit, 2010, Development of a high sensitivity rapid sandwich ELISA procedure and its comparison with the conventional approach, Anal. Chem., 82, 7049, 10.1021/ac101339q
Vashist, S.K. (2011). A highly-sensitive and rapid Surface Plasmon Resonance immunoassay procedure based on the covalent-oriented immobilization of antibodies. Protoc. Exch.
Vashist, S.K., O’Sullivan, S.A., O’Neill, F.T., Hölthofer, H., O’Reilly, B., and Dixit, C.K. (2010). A Multi-Well Plate for Biological Assays. (WO/2010/044083), W.I.P.O. Patent.
Dixit, 2011, Evaluation of apparent non-specific protein loss due to adsorption on sampling tube surfaces and/or comprised immunogenicity, Analyst, 136, 1406, 10.1039/c0an00689k
Zheng, D., Vashist, S.K., Luong, J.H.T., Al-Rubeaan, K., and Sheu, F.-S. (2012). Mediatorless amperometric glucose biosensing using 3-aminopropyltriethoxysilane functionalized graphene. Talanta, in press.
Zheng, 2012, Rapid and simple preparation of a reagentless glucose electrochemical biosensor, Analyst, 137, 3800, 10.1039/c2an35128e
Available online:http://www.piercenet.com/instructions/2160475.pdf.
Available online:http://piercenet.com/instructions/2160650.pdf.
East, 2011, QD-antibody conjugates via carbodiimide-mediated coupling: A detailed study of the variables involved and a possible new mechanism for the coupling reaction under aqueous conditions, Langmuir, 27, 13888, 10.1021/la203273p
Nakajima, 1995, Mechanism of amide formation by carbodiimide for bioconjugation in aqueous media, BioconjugateChem., 6, 123, 10.1021/bc00031a015
The Human IgG Subclasses. Available online:http://wolfson.huji.ac.il/purification/PDF/affinity/CALBIOCHEM_HumanIgG_Subclasses.pdf.
Chemistry of Crosslinking. Available online:http://www.piercenet.com/browse.cfm?fldID=CE4D6C5C-5946-4814-9904-C46E01232683.