COMPOSITION OF VOLATILE ORGANIC COMPOUNDS IN DIATHERMY PLUME AS DETECTED BY SELECTED ION FLOW TUBE MASS SPECTROMETRY

ANZ Journal of Surgery - Tập 77 Số 1-2 - Trang 20-23 - 2007
Andrew R. Moot1, Katherine M. Ledingham2, Paul F. Wilson2, Senti T. Senthilmohan2, David R. Lewis2, Justin Roake2, Randall A. Allardyce2
1Department of Surgery, Christchurch School of Medicine, Christchurch, New Zealand
2* Department of Surgery, Christchurch School of Medicine, and † Syft Technologies Limited, Christchurch, New Zealand

Tóm tắt

Background:  There is some evidence that surgical plume may pose a risk to health professionals, but the risks posed by volatile organic compounds have not been thoroughly investigated.

Methods:  The composition of volatile organic compounds in diathermy plume produced during surgery was analysed by selected ion flow tube mass spectrometry.

Results:  Hydrogen cyanide (3–51 parts per million), acetylene (2–8 parts per million), and 1,3‐butadiene (0.15–0.69 parts per million) were identified in the plume.

Conclusion:  Although there is no evidence of adverse health effects from the volatile organic compound in diathermy plume, the evidence that it is safe to breathe this plume is lacking. Therefore, we would recommend the use of smoke evacuators where practical.

Từ khóa


Tài liệu tham khảo

10.1007/s004649900774

10.1002/lsm.1900070414

10.1016/S0002-9610(99)00109-9

10.1089/clm.1999.17.199

10.1001/archderm.138.10.1303

10.1001/jama.1988.03720080033024

10.1016/S0190-9622(89)70146-8

10.1177/019459989110400206

10.1016/S0190-9622(98)70500-6

10.1017/S0022215100135686

10.1016/0190-9622(95)90065-9

10.1007/BF01463570

Calero L, 2003, [Laryngeal papillomatosis – first recognition in Germany as an occupational disease in an operating room nurse.], Laryngorhinootologie, 82, 790

10.1016/S0886-3350(00)00813-0

10.1016/S0161-6420(99)90442-6

10.1007/BF02523843

10.1002/bjs.1800831241

10.1097/01.PRS.0000131886.72932.C3

10.1002/rcm.1566

10.1016/S1387-3806(03)00290-2

10.1097/00006534-199205000-00001

10.1016/0165-1218(81)90120-8

10.1016/S1387-3806(02)00662-0

El Ghawabi SH, 1975, Chronic cyanide exposure: a clinical, radioisotope, and laboratory study, Br. J. Ind. Med, 32, 215

10.1093/jat/4.4.161

Blanc P, 1985, Cyanide intoxication among silver‐reclaiming workers, JAMA, 253, 367, 10.1001/jama.1985.03350270065023

Laugesen M, 2005, Scope for regulation of cigarette smoke toxicity according to brand differences in published toxicant emissions, N. Z. Med. J, 118, U1401

LaugesenM FowlesJ.Marlboro UltraSmooth: a potentially reduced exposure cigarette?Tob. Control2006;15:430–35.

US Department of Health and Human Services.The Health Consequences of Smoking: Nicotine Addiction. A Report of the Surgeon General 1988. Rockville MD:U.S. Department of Health and Human Services Public Health Service Centers for Disease Control Center for Health Promotion and Education Office on Smoking and Health 1988. DHHS Publication No. (CDC) 88–8406.

10.1034/j.1399-6576.2002.461003.x

10.1097/00000542-200010000-00008

US Department of Labour.Occupational Safety and Health Administration. Safety and Health Topics: Permissible Exposure Limits. [updated 3 April 2006; cited 9 July 2003.]Available from URL:www.osha.gov/SLTC/pel/

10.1002/bjs.4214

Hou MF, 2002, Reducing dust using the electrocautery pencil with suction combined with the infusion catheter in mastectomy, Am. Surg, 68, 808, 10.1177/000313480206800915