Biosensors for the Detection of Food Pathogens
Tóm tắt
Food pathogens frequently cause foodborne diseases. There is a need to rapidly identify the source of the bacteria in order to contain their spread and epidemics. A pre-enrichment culture or a direct culture on agar plate are standard microbiological methods. In this review, we present an update on alternative molecular methods to nucleic acid-based detection for species identification. Biosensor-based methods rely on the recognition of antigen targets or receptors by antibodies, aptamers or high-affinity ligands. The captured antigens may be then directly or indirectly detected through an antibody or high-affinity and high-specificity recognition molecule. Various different detection methods are discussed, from label-free sensors and immunosensors to fluorescence-based ones. Each method shows advantages and disadvantages in terms of equipment, sensitivity, simplicity and cost-effectiveness. Finally, lab-on-a-chip (LOC) devices are introduced briefly, with the potential to be fast, sensitive and useful for on-site bacteria detection in food processing laboratories to check potential contamination by sample monitoring combined with a rapid pre-enrichment step.
Từ khóa
Tài liệu tham khảo
Scallan, 2011, Foodborne illness acquired in the United States—Major pathogens, Emerg. Infect. Dis., 7, 7, 10.3201/eid1701.P11101
Manera, 2013, SPR based immunosensor for detection of Legionella pneumophila in water samples, Optics Comm., 294, 420, 10.1016/j.optcom.2012.12.064
Pathatrix® Auto System. Available online:http://www.lifetechnologies.com/cn/zh/home/industrial/food-safety/pathatrix-auto-system.html.
Poltronieri, 2009, Detection of Listeria monocytogenes through RealTime PCR and biosensor methods, Plant Soil Environ., 9, 363, 10.17221/139/2009-PSE
Poltronieri, 2009, A filtration-based real-time PCR method for the quantitative detection of viable Salmonella enterica and Listeria monocytogenes in food samples, Food Microbiol., 26, 311, 10.1016/j.fm.2008.12.006
Kuang, 2013, A one-step homogeneous sandwich immunosensor for Salmonella detection based on magnetic nanoparticles (MNPs) and quantum dots (QDs), Int. J. Mol. Sci., 14, 8603, 10.3390/ijms14048603
2013, Aptamer-based analysis: A promising alternative for food safety control, Sensors, 13, 16292, 10.3390/s131216292
Paniel, 2013, Aptasensor and genosensor methods for detection of microbes in real world samples, Methods, 64, 229, 10.1016/j.ymeth.2013.07.001
Dutt, 2013, Immobilization of P22 bacteriophage Tailspike protein on Si surface for optimized Salmonella capture, J. Anal. Bioanal. Tech., S7, 7, 10.4172/2155-9872.S7-007
Cimaglia, 2012, Quantum dot nanoparticle-based lateral flow assay for rapid detection of Mycobacterium species using anti-FprA antibodies, Nanotechnol. Dev., 2, e5, 10.4081/nd.2012.e5
Bergwerff, 2006, Surface plasmon resonance biosensors for detection of pathogenic microorganisms: Strategies to secure food and environmental safety, J. AOAC Int., 89, 826, 10.1093/jaoac/89.3.826
Deisingh, 2004, Biosensors for the detection of bacteria, Can. J. Microbiol., 50, 69, 10.1139/w03-095
Mazumdar, 2008, A rapid serological assay for prediction of Salmonella infection status in slaughter pigs using surface plasmon resonance, J. Microbiol. Meth., 75, 545, 10.1016/j.mimet.2008.08.011
Dudak, 2009, Rapid and label-free bacteria detection by surface plasmon resonance (SPR) biosensors, Biotechnol. J., 4, 1003, 10.1002/biot.200800316
Sun, 2014, Optical biosensors for label-free detection of biomolecular interactions, Instrum. Sci. Technol., 42, 109, 10.1080/10739149.2013.843060
Marusov, 2012, A microarray biosensor for multiplexed detection of microbes using grating-coupled surface plasmon resonance imaging, Environ. Sci. Technol., 46, 348, 10.1021/es201239f
Guo, 2012, A piezoelectric immunosensor for specific capture and enrichment of viable pathogens by quartz crystal microbalance sensor, followed by detection with antibody-functionalized gold nanoparticles, Biosens. Bioelectron., 38, 177, 10.1016/j.bios.2012.05.024
Granqvist, 2013, Label-enhanced Surface Plasmon Resonance: A new concept for improved performance in optical biosensor analysis, Sensors, 13, 15348, 10.3390/s131115348
Wang, 2011, Subtractive inhibition assay for the detection of E. coli O157:H7 using surface plasmon resonance, Sensors, 11, 2728, 10.3390/s110302728
Wang, 2013, Monitoring of Escherichia coli O157:H7 in food samples using lectin based surface plasmon resonance biosensor, Food Chem., 136, 1303, 10.1016/j.foodchem.2012.09.069
Li, 2012, Disposable immunochips for the detection of Legionella pneumophila using electrochemical impedance spectroscopy, Anal. Chem., 84, 3485, 10.1021/ac3003227
Silley, 1996, Impedance microbiology—A rapid change for microbiologists, J. Appl. Bacteriol., 80, 233, 10.1111/j.1365-2672.1996.tb03215.x
Wawerla, 1999, Impedance microbiology: Applications in food hygiene, J. Food Prot., 62, 1488, 10.4315/0362-028X-62.12.1488
Wan, 2011, Impedimetric immunosensor doped with reduced graphene sheets fabricated by controllable electrodeposition for the non-labelled detection of bacteria, Biosens. Bioelectron., 26, 1959, 10.1016/j.bios.2010.08.008
Yang, 2003, Detection of viable Salmonella typhimurium by impedance measurement of electrode capacitance and medium resistance, Biosens. Bioelectron., 19, 495, 10.1016/S0956-5663(03)00229-X
Yang, 2004, Interdigited microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium, Biosens. Bioelectron., 19, 1139, 10.1016/j.bios.2003.10.009
Primiceri, 2012, Towards pancreatic cancer diagnosis by EIS biochips, Lab Chip, 13, 730
Primiceri, 2011, Automatic transwell assay by an EIS cell chip to monitor cell migration, Lab Chip, 11, 4081, 10.1039/c1lc20540d
Ruan, 2002, Immunobiosensor chips doe detection of Escherichia coli O157:H7 using electrochemical impedance spectroscopy, Anal. Chem., 74, 4814, 10.1021/ac025647b
Yang, 2004, Interdigitated array microelectrode-based electrodechemical impedance immunosensor for detection of Escherichia coli O157:H7, Anal. Chem., 76, 1107, 10.1021/ac0352575
Radhakrishnan, 2013, Detection of Listeria monocytogenes by electrochemical impedance spectroscopy, Electroanalysis, 25, 2231, 10.1002/elan.201300140
Yang, 2009, A reusable capacitive immunosensor for detection of Salmonella spp. based on grafted ethylene diamine and self-assembled gold nanoparticle monolayers, Anal. Chim. Acta, 647, 159, 10.1016/j.aca.2009.06.008
Wang, 2008, TiO2 nanowire bundle microelectrode based impedance immunosensor for rapid and sensitive detection of Listeria monocytogenes, Nano Lett., 9, 2625, 10.1021/nl080366q
Jiang, 2014, Smartphone based portable bacteria pre-concentrating microfluidicsensor and impedance sensing, Sens. Actuators B Chem., 193, 653, 10.1016/j.snb.2013.11.103
Regan, 2014, A novel cobalt complex for enhancing amperometric and impedimetric DNA detection, Electrochim. Acta, 128, 10, 10.1016/j.electacta.2013.10.028
Hu, 2010, Carbon nanostructure-based field-effect transistors for label-free chemical/biological sensors, Sensors, 10, 5133, 10.3390/s100505133
Li, 2012, Amperometric immunosensor for the detection of Escherichia coli O157:H7 in food specimens, Anal. Biochem., 421, 227, 10.1016/j.ab.2011.10.049
Li, 2011, Label-free capacitive immunosensor based on quartz crystal Au electrode for rapid and sensitive detection of Escherichia coli O157:H7, Anal. Chim. Acta, 687, 89, 10.1016/j.aca.2010.12.018
Liu, 2011, Functionalized arrays of Raman-enhancing nanoparticles for capture and culture-free analysis of bacteria in human blood, Nat. Commun., 2, 538, 10.1038/ncomms1546
Cheng, 2012, Rapid (<5 min) identification of pathogen in human blood by electrokinetic concentration and surface-enhanced Raman spectroscopy, Sci. Rep., 3, 2365, 10.1038/srep02365
Ravindranath, 2009, Biofunctionalized magnetic nanoparticle integrated mid-infrared pathogen sensor for food matrixes, Anal. Chem., 81, 2840, 10.1021/ac802158y
Fornara, 2008, Tailored magnetic nanoparticles for direct and sensitive detection of biomolecules in biological samples, Nano Lett., 8, 3423, 10.1021/nl8022498
Kaittanis, 2012, Rapid and sensitive detection of an intracellular pathogen in human peripheral leukocytes with hybridizing magnetic relaxation nanosensors, PLoS One, 7, e35326, 10.1371/journal.pone.0035326
Maruccio, 2009, A nanobiosensor to detect single hybridization events, Analyst, 134, 2458, 10.1039/b920559b
Chen, 2012, A protein transistor made of an antibody molecule and two gold nanoparticles, Nat. Nanotechnol., 7, 197, 10.1038/nnano.2012.7
Maruccio, 2012, Molecular electronics: Protein transistors strike gold, Nat. Nanotechnol., 7, 147, 10.1038/nnano.2012.27
Chen, 2013, DNA sequencing using electrical conductance measurements of a DNA polymerase, Nat. Nanotechnol., 8, 452, 10.1038/nnano.2013.71
Sarkar, 2014, Optical biosensors with an integrated Mach-Zender interferometer for detection of Listeria monocytogenes, Biomed. Microdevices, 16, 509, 10.1007/s10544-014-9853-5
Leach, 2010, Same-day detection of Escherichia coli O157:H7 from spinach by using electrochemiluminescent and cytometric bead array biosensors, Appl. Environ. Microbiol., 76, 8044, 10.1128/AEM.01990-10
Cimaglia, F., and Poltronieri, P. (2014). Unpublished work.
Mujawar, 2013, Rapid mastitis detection assay on porous nitrocellulose membrane slides, Anal. Bioanal. Chem., 405, 7469, 10.1007/s00216-013-7192-7
Eickhoff, 2013, Planar protein arrays in microtiter plates: Development of a new format towards accurate, automation-friendly and affordable (a(3)) diagnostics, Adv. Biochem. Eng. Biotechnol., 133, 149
Rastogi, 2009, Magnetic bead and fluorescent silica nanoparticles based optical immunodetection of staphylococcal enterotoxin B (SEB) in bottled water, Sens. Transducers J., 7, 191
Balsam, 2012, Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam, Sens. Actuators B Chem., 171–172, 141, 10.1016/j.snb.2012.02.003
Thompson, 2009, An adaptable, portable microarray reader for biodetection, Sensors, 9, 2524, 10.3390/s90402524
Melin, 2008, Ligation-based molecular tools for lab-on-chip devices, New Biotechnol., 25, 42, 10.1016/j.nbt.2008.02.003
Dogra, 2012, Investigating ligand-receptor interactions at bilayer surface using electronic absorption spectroscopy and fluorescence resonance energy transfer, Langmuir, 28, 12989, 10.1021/la300724z