Biomechanical Properties of Volar Hybrid and Locked Plate Fixation in Distal Radius Fractures
Tài liệu tham khảo
Orbay, 2004, Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient, J Hand Surg, 29A, 96, 10.1016/j.jhsa.2003.09.015
Orbay, 2002, Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report, J Hand Surg, 27A, 205, 10.1053/jhsu.2002.32081
Kamano, 2002, Palmar plating for dorsally displaced fractures of the distal radius, Clin Orthop Relat Res, 397, 403, 10.1097/00003086-200204000-00047
Willis, 2006, Internal fixation of dorsally displaced fractures of the distal part of the radius, J Bone Joint Surg, 88A, 2411, 10.2106/00004623-200611000-00013
Boswell, 2007, Mechanical characteristics of locking and compression plate constructs applied dorsally to distal radius fractures, J Hand Surg, 32A, 623, 10.1016/j.jhsa.2007.03.005
Estes, 2008, Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations, J Orthop Trauma, 22, 312, 10.1097/BOT.0b013e31817279b8
Sommers, 2007, A surrogate long-bone model with osteoporotic material properties for biomechanical testing of fracture implants, J Biomech, 40, 3297, 10.1016/j.jbiomech.2007.04.024
Spivak, 1994, Hydroxyapatite enhancement of posterior spinal instrumentation fixation, Spine (Phila PA 1976), 19, 955, 10.1097/00007632-199404150-00015
Jazrawi, 2000, A biomechanical comparison of Schuhli nuts or cement augmented screws for plating of humeral fractures, Clin Orthop Relat Res, 377, 235, 10.1097/00003086-200008000-00031
Leung, 2003, Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate—a biomechanical study in a cadaveric model, J Hand Surg, 28B, 263, 10.1016/S0266-7681(03)00011-1
McCall, 2007, Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanic study, J Hand Surg, 32A, 806, 10.1016/j.jhsa.2007.04.016
Mehling, 2010, Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study, J Hand Surg, 35A, 885, 10.1016/j.jhsa.2010.03.027
Kowalski, 1996, A comparative biomechanical evaluation of a noncontacting plate and currently used devices for tibial fixation, J Trauma, 40, 5, 10.1097/00005373-199601000-00002
Rampoldi, 2007, Complications of volar plating of distal radius fractures, Acta Orthop Belg, 73, 714
Arora, 2007, Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate, J Orthop Trauma, 21, 316, 10.1097/BOT.0b013e318059b993
Benson, 2006, Two potential causes of EPL rupture after distal radius volar plate fixation, Clin Orthop Relat Res, 451, 218, 10.1097/01.blo.0000223998.02765.0d
Hattori, 2008, Delayed rupture of extensor digitorum communis tendon following volar plating of distal radius fracture, Hand Surg, 13, 183, 10.1142/S0218810408004055
Power, 2003, Bone remodeling at the endocortical surface of the human femoral neck: a mechanism for regional cortical thinning in cases of hip fracture, J Bone Miner Res, 18, 1775, 10.1359/jbmr.2003.18.10.1775
Spadaro, 1994, Cortical and trabecular bone contribute strength to the osteopenic distal radius, J Orthop Res, 12, 211, 10.1002/jor.1100120210