Bilayer lipid membrane‐based electrochemical biosensors

Journal of Clinical Laboratory Analysis - Tập 2 Số 4 - Trang 256-264 - 1988
H. Ti Tien1
1Membrane Biophysics Laboratory, Michigan State University, East Lansing, Michigan

Tóm tắt

AbstractThis paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLMs for optical sensors. Suggestions for improvements in the development of BLM‐based electrochemical biosensors for the clinical setting are also presented.

Từ khóa


Tài liệu tham khảo

10.1016/B978-0-12-136101-3.50010-6

10.1083/jcb.91.3.189s

Benga G, 1985, Structure and Properties of Cell Membranes

10.1161/01.CIR.26.5.1167

Tien HT, 1974, Bilayer Lipid Membranes (BLM): Theory and Practice

Davison SG, 1985, Progress in Surface Science, 169

CarterFL WohltjenH(eds.): Proceedings of the 3rd. International symposium on Molecular Electronic Devices Arlington VA USA 6‐8 October1986. North‐Holland Amsterdam 1988.

Ivanov I, 1988, Thin Liquid Films

10.1016/0039-9140(83)80214-8

10.1016/S0003-2670(00)84729-7

10.1016/0079-6816(86)90016-X

Kutnik J, 1987, Apparatus and techniques for measurement of electrical properties of bilayer lipid membranes (BLM), J Electrophysiol Tech, 14, 211

10.1016/0302-4598(84)87033-6

10.1016/0302-4598(86)80002-2

Metzler DE, 1977, Biochemistry: The Chemical Reactions of Living Cells

10.1126/science.153.3732.185

Vassilev PM, 1985, Structure and Properties of Cell Membranes, 63

10.1007/BF01964335

10.1016/0006-291X(79)92121-1

Badzhinyan SA, 1982, Effect of prostaglandins on ionic conductivity of model membranes, Biofizika, 27, 277

10.1085/jgp.69.5.633

10.1016/0005-2736(82)90011-6

10.1002/jps.2600580202

10.1016/0302-4598(86)80042-3

10.1016/0005-2736(84)90368-7

10.1016/0006-2952(82)90090-9

10.1016/0005-2736(78)90003-2

10.1016/0005-2736(82)90588-0

Rudnev VS, 1984, Effect of hemolysin from the sea anemone radianthus macrodactylus on lipid membrane conductivity, Biophys J Membr, 1, 1019

Blumenthal R, 1984, Mechanism of tetanolysin‐induced membrane damage: studies with black lipid membranes, J Bacteriol, 157, 321, 10.1128/jb.157.1.321-323.1984

10.1146/annurev.bi.46.070177.000405

Mayer MM, 1981, The Johns Hopkins Med J, 148, 243

10.1073/pnas.73.8.2852

10.1007/BF00743104

10.3109/08820138409025453

10.1111/j.1751-1097.1978.tb07724.x

Marino AA, 1988, Modern Bioelectricity, 181

10.1016/S0003-2670(01)93427-0

Antonili R, 1982, Transport in Membranes: Model Systems and Reconslitution, 57

10.1111/j.1751-1097.1987.tb04885.x

10.1080/00268948808078732

Davis C, 1986, Fiber Optic Sensor Technology Handbook

Thompson RB, 1988, Biosensors and Bioelectronic Systems

Schuetzlc D, 1986, Fundamentals and Applications of Chemical Sensors, 394, 10.1021/bk-1986-0309

Janata J, 1987, Electrochemical biosensors, 258

Turner APF, 1987, Biosensor Fundamentals and Applications, 770