Automatic detection of anomalies in screening mammograms
Tóm tắt
Diagnostic performance in breast screening programs may be influenced by the prior probability of disease. Since breast cancer incidence is roughly half a percent in the general population there is a large probability that the screening exam will be normal. That factor may contribute to false negatives. Screening programs typically exhibit about 83% sensitivity and 91% specificity. This investigation was undertaken to determine if a system could be developed to pre-sort screening-images into normal and suspicious bins based on their likelihood to contain disease. Wavelets were investigated as a method to parse the image data, potentially removing confounding information. The development of a classification system based on features extracted from wavelet transformed mammograms is reported. In the multi-step procedure images were processed using 2D discrete wavelet transforms to create a set of maps at different size scales. Next, statistical features were computed from each map, and a subset of these features was the input for a concerted-effort set of naïve Bayesian classifiers. The classifier network was constructed to calculate the probability that the parent mammography image contained an abnormality. The abnormalities were not identified, nor were they regionalized. The algorithm was tested on two publicly available databases: the Digital Database for Screening Mammography (DDSM) and the Mammographic Images Analysis Society’s database (MIAS). These databases contain radiologist-verified images and feature common abnormalities including: spiculations, masses, geometric deformations and fibroid tissues. The classifier-network designs tested achieved sensitivities and specificities sufficient to be potentially useful in a clinical setting. This first series of tests identified networks with 100% sensitivity and up to 79% specificity for abnormalities. This performance significantly exceeds the mean sensitivity reported in literature for the unaided human expert. Classifiers based on wavelet-derived features proved to be highly sensitive to a range of pathologies, as a result Type II errors were nearly eliminated. Pre-sorting the images changed the prior probability in the sorted database from 37% to 74%.
Tài liệu tham khảo
Canadian-Cancer-Statistics-2012---English.pdf. Canadian Cancer Society’s Advisory Committee on Cancer Statistics: Canadian Cancer Statistics 2012. 2013, Toronto: Canadian Cancer Society
Wadden N: Breast cancer screening in Canada: a review. Can Assoc Radiol J. 2005, 56 (5): 271-275.
Wadden N, Doyle GP: Breast cancer screening in Canada: a review (vol 56, pg 5, 2005). Can Assoc Radiol J. 2006, 57 (2): 67-
Cheng HD, Shi XJ, Min R, Hu LM, Cai XR, Du HN: Approaches for automated detection and classification of masses in mammograms. Pattern Recogn. 2006, 39 (4): 646-668. 10.1016/j.patcog.2005.07.006.
Jiang Y, Nishikawa RM, Schmidt RA, Metz CE: Comparison of independent double readings and computer-aided diagnosis (CAD) for the diagnosis of breast calcifications. Acad Radiol. 2006, 13 (1): 84-94. 10.1016/j.acra.2005.09.086.
Sentelle S, Sentelle C, Sutton MA: Multiresolution-based segmentation of calcifications for the early detection of breast cancer. Real-Time Imaging. 2002, 8 (3): 237-252. 10.1006/rtim.2001.0285.
Tang JS, Rangayyan RM, Xu J, El Naqa I, Yang YY: Computer-aided detection and diagnosis of breast cancer with mammography: recent advances. Ieee T Inf Technol B. 2009, 13 (2): 236-251.
Torrent A, Oliver A, Llado X, Marti R, Freixenet J: A supervised micro-calcification detection approach in digitised mammograms. Ieee International Conference on Image Processing. 2010, 2010: 4345-4348.
Alto H, Rangayyan RM, Paranjape RB, Desautels JEL, Bryant H: An indexed atlas of digital mammograms for computer-aided diagnosis of breast cancer. Ann Telecommun. 2003, 58 (5–6): 820-835.
Andre TCSS, Rangayyan RM: Classification of breast masses in mammograms using neural networks with shape, edge sharpness, and texture features. J Electron Imaging. 2006, 15 (1): 013019-013019-10-
Freixenet J, Oliver A, Marti R, Llado X, Pont J, Perez E, Denton ERE, Zwiggelaar R: Eigendetection of masses considering false positive reduction and breast density information. Med Phys. 2008, 35 (5): 1840-1853. 10.1118/1.2897950.
Guliato D, Rangayyan RM, Adorno F, Ribeiro MMG: Analysis and classification of breast masses by fuzzy-set-based image processing. Digital Mammography. Edited by: Peitgen HO. 2003, Heidelberg: Springer, 195-197.
Guliato D, Rangayyan RM, Carnielli WA, Zuffo JA, Desautels JEL: Segmentation of breast tumors in mammograms by fuzzy region growing. P Ann Int Ieee Embs. 1998, 20: 1002-1005.
Guliato D, de Carvalho JD, Rangayyan RM, Santiago SA: Feature extraction from a signature based on the turning angle function for the classification of breast tumors. J Digit Imaging. 2008, 21 (2): 129-144. 10.1007/s10278-007-9069-9.
Gur D, Stalder JS, Hardesty LA, Zheng B, Sumkin JH, Chough DM, Shindel BE, Rockette HE: Computer-aided detection performance in Mammographic examination of masses: assessment1. Radiology. 2004, 233 (2): 418-423. 10.1148/radiol.2332040277.
Llado X, Oliver A, Freixenet J, Marti R, Marti J: A textural approach for mass false positive reduction in mammography. Comput Med Imag Grap. 2009, 33 (6): 415-422. 10.1016/j.compmedimag.2009.03.007.
Rangayyan RM, Ayres FJ, Desautels JEL: A review of computer-aided diagnosis of breast cancer: Toward the detection of subtle signs. J Franklin I. 2007, 344 (3–4): 312-348.
Prajna S, Rangayyan RM, Ayres FJ, Desautels JEL: Detection of architectural distortion in mammograms acquired prior to the detection of breast cancer using texture and fractal analysis - art. no. 691529. P Soc Photo-Opt Ins. 2008, 6915: 91529-
Astley SM: Computer-aided detection for screening mammography. Acad Radiol. 2004, 11 (10): 1139-1143. 10.1016/j.acra.2004.07.009.
Gilbert FJ, Astley SM, Gillan MG, Agbaje OF, Wallis MG, James J, Boggis CR, Duffy SW, Group CI: Single reading with computer-aided detection for screening mammography. New Engl J Med. 2008, 359 (16): 1675-1684. 10.1056/NEJMoa0803545.
Padmanabhan S, Sundararajan R: Texture and statistical analysis of mammograms: A novel method to detect tumor in Breast Cells. 2012, : Machine Vision and Image Processing (MVIP), 2012 International Conference on: 14–15 Dec. 2012 2012, 157-160.
Choi JY, Kim DH, Choi SH, Ro YM: Multiresolution local binary pattern texture analysis for false positive reduction in computerized detection of breast masses on mammograms. Proc Spie. 2012, 8315: 83152B-7-10.1117/12.912392.
Choi JY, Ro YM: Multiresolution local binary pattern texture analysis combined with variable selection for application to false-positive reduction in computer-aided detection of breast masses on mammograms. Phys Med Biol. 2012, 57 (21): 7029-7052. 10.1088/0031-9155/57/21/7029.
Azavedo E, Zackrisson S, Mejare I, Heibert Arnlind M: Is single reading with computer-aided detection (CAD) as good as double reading in mammography screening? A systematic review. BMC Med Imaging. 2012, 12: 22-10.1186/1471-2342-12-22.
Houssami N, Given-Wilson R: Incorporating new technologies into clinical practice without evidence of effectiveness in prospective studies: computer-aided detection (CAD) in breast screening reinforces the need for better initial evaluation. Breast. 2007, 16 (3): 219-221. 10.1016/j.breast.2007.04.006.
Heath M, Bowyer K, Kopans D: The digital database for screening mammography. 2001, Madison: Medical Physics Publishing
Heath M, Bowyer K, Kopans D, Kegelmeyer P, Moore R, Chang K, Munishkumaran S: Current status of the digital database for screening mammography. 1998, Digital Mammography edn: Springer, 457-460.
Heath M, Bowyer K, Kopans D, Moore R, Kegelmeyer P: The digital database for screening mammography. Proceedings of the 5th international workshop on digital mammography. 2000, : , 212-218.
Suckling J, Parker J, Dance D, Astley S, Hutt I, Boggis C, Ricketts I, Stamatakis E, Cerneaz N, Kok S-L: The mammographic image analysis society digital mammogram database. 1994
Sonka M: Image processing, analysis, and machine vision. 2007, Mason, OH: Thomson: International student edn
Cui J, Loewy J, Kendall EJ: Automated search for arthritic patterns in infrared spectra of synovial fluid using adaptive wavelets and fuzzy C-means analysis. IEEE Transactions on Bio-Medical Engineering. 2006, 53 (5): 800-809. 10.1109/TBME.2006.872813.
Cheng HD, Cai XP, Chen XW, Hu LM, Lou XL: Computer-aided detection and classification of microcalcifications in mammograms: a survey. Pattern Recogn. 2003, 36 (12): 2967-2991. 10.1016/S0031-3203(03)00192-4.
Ferreira CB, Borges DL: Analysis of mammogram classification using a wavelet transform decomposition. Pattern Recogn Lett. 2003, 24: 973-982. 10.1016/S0167-8655(02)00221-0.
Taylor P, Given-Wilson R, Champness J, Potts HWW, Johnston K: Assessing the impact of CAD on the sensitivity and specificity of film readers. Clin Radiol. 2004, 59 (12): 1099-1105. 10.1016/j.crad.2004.04.017.
Rangayyan RM, Nguyen TM, Ayres FJ, Nandi AK: Effect of pixel resolution on texture features of breast masses in mammograms. J Digit Imaging. 2010, 23 (5): 547-553. 10.1007/s10278-009-9238-0.
Coldman AJ, Major D, Doyle GP, D’yachkova Y, Phillips N, Onysko J, Shumak R, Smith NE, Wadden N: Organized breast screening programs in Canada: effect of radiologist reading volumes on outcomes1. Radiology. 2006, 238 (3): 809-815. 10.1148/radiol.2382041684.
Elmore JG, Armstrong K, Lehman CD, Fletcher SW: Screening for breast cancer. Jama-J Am Med Assoc. 2005, 293 (10): 1245-1256. 10.1001/jama.293.10.1245.
Fenton JJ, Abraham L, Taplin SH, Geller BM, Carney PA, D’Orsi C, Elmore JG, Barlow WE: Effectiveness of computer-aided detection in community mammography practice. J Natl Cancer Inst. 2011, 103 (15): 1152-1161. 10.1093/jnci/djr206.
Kendall EJ, Barnett MG: Image analysis. 2010, In. vol. 12808099. US
The pre-publication history for this paper can be accessed here:http://www.biomedcentral.com/1471-2342/13/43/prepub
