A rigid poly(dimethylsiloxane) sandwich electrophoresis microchip based on thin‐casting method

Electrophoresis - Tập 27 Số 14 - Trang 2917-2923 - 2006
Changchun Liu1, Dafu Cui1, Haoyuan Cai1, Xing Chen1, Zhaoxin Geng1
1State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P. R. China

Tóm tắt

AbstractWe present a novel concept of glass/poly(dimethylsiloxane) (PDMS)/glass sandwich microchip and developed a thin‐casting method for fabrication. Unlike the previously reported casting method for fabricating PDMS microchip, several drops of PDMS prepolymer were first added on the silanizing SU‐8 master, then another glass plate was placed over the prepolymer as a cover plate, and formed a glass plate/PDMS prepolymer/SU‐8 master sandwich mode. In order to form a thin PDMS membrane, a weight was placed on the glass plate. After the whole sandwich mode was cured at 80°C for 30 min, the SU‐8 master was easily peeled and the master microstructures were completely transferred to the PDMS membrane which was tightly stuck to the glass plate. The microchip was subsequently assembled by reversible sealing with the glass cover plate. We found that this PDMS sandwich microchip using the thin‐casting method could withstand internal pressures of >150 kPa, more than 5 times higher than that of the PDMS hybrid microchip with reversible sealing. In addition, it shows an excellent heat‐dissipating property and provides a user‐friendly rigid interface just like a glass microchip, which facilitates manipulation of the microchip and fix tubing. As an application, PDMS sandwich microchips were tested in the capillary electrophoresis separation of fluorescein isothiocyanate‐labeled amino acids.

Từ khóa


Tài liệu tham khảo

10.1016/0165-9936(91)85116-9

10.1021/ac0202435

10.1021/ac020239t

10.1007/s00216-001-1191-9

10.1021/ac00041a030

10.1016/0021-9673(92)80293-4

10.1021/ac9804487

10.1074/mcp.M100022-MCP200

10.1021/ac0264574

10.1016/S0925-4005(02)00468-9

10.1002/elps.200305584

10.1021/ja021045y

10.1021/ac010938q

10.1109/84.825780

10.1021/ac9912294

10.1021/ac0255330

10.1016/j.sbi.2003.09.010

10.1021/ac010502a

10.1073/pnas.061014198

10.1021/ac026277u

10.1021/ac000685l

10.1021/ac970558y

10.1002/(SICI)1520-667X(1998)10:5<413::AID-MCS4>3.0.CO;2-J

10.1021/ac9701997

10.1021/ac010343v

10.1016/j.snb.2003.11.014

10.1021/ac9703919

10.1021/ar010110q

10.1146/annurev.bioeng.4.112601.125916

10.1002/(SICI)1522-2683(20000101)21:1<27::AID-ELPS27>3.0.CO;2-C

10.1021/ac048811z

10.1002/1522-2683(200204)23:7/8<1129::AID-ELPS1129>3.0.CO;2-4

10.1002/(SICI)1522-2683(20000101)21:1<107::AID-ELPS107>3.0.CO;2-Y

10.1126/science.1083694

10.1021/jp0377937

Fujii T., 2002, Microelectron. Eng., 61

10.1021/ac980656z

10.1088/0960-1317/13/5/332

10.1021/ac011077o

10.1016/S0925-4005(00)00745-0

10.1016/S0925-4005(97)00294-3

10.1016/j.bioeng.2004.11.001

10.1016/j.snb.2004.10.022

10.1039/b206808g