A quality monitoring program for red blood cell components: in vitro quality indicators before and after implementation of semiautomated processing

Transfusion - Tập 54 Số 10 - Trang 2534-2543 - 2014
Jason P. Acker1,2, Arild E. Hansen1, Jayme D.R. Kurach1, Tracey R. Turner1, Ioana M Croteau1, Craig Jenkins3
1Canadian Blood Services, Edmonton, Alberta, Canada
2Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta, Canada
3Canadian Blood Services, Ottawa, Ontario, Canada

Tóm tắt

BackgroundCanadian Blood Services has been conducting quality monitoring of red blood cell (RBC) components since 2005, a period spanning the implementation of semiautomated component production. The aim was to compare the quality of RBC components produced before and after this production method change.Study Design and MethodsData from 572 RBC units were analyzed, categorized by production method: Method 1, RBC units produced by manual production methods; Method 2, RBC units produced by semiautomated production and the buffy coat method; and Method 3, RBC units produced by semiautomated production and the whole blood filtration method. RBC units were assessed using an extensive panel of in vitro tests, encompassing regulated quality control criteria such as hematocrit (Hct), hemolysis, and hemoglobin (Hb) levels, as well as adenosine triphosphate, 2,3‐diphosphoglycerate, extracellular K+ and Na+ levels, methemoglobin, p50, RBC indices, and morphology.ResultsThroughout the study, all RBC units met mandated Canadian Standards Association guidelines for Hb and Hct, and most (>99%) met hemolysis requirements. However, there were significant differences among RBC units produced using different methods. Hb content was significantly lower in RBC units produced by Method 2 (51.5 ± 5.6 g/unit; p < 0.001). At expiry, hemolysis was lowest in Method 2–produced RBC units (p < 0.05) and extracellular K+ levels were lowest in units produced by Method 1 (p < 0.001).ConclusionWhile overall quality was similar before and after the production method change, the observed differences, although small, indicate a lack of equivalency across RBC products manufactured by different methods.

Từ khóa


Tài liệu tham khảo

10.1016/j.tracli.2008.04.006

10.1016/j.transci.2006.11.003

10.1111/trf.12143

10.1111/j.1423-0410.1988.tb04699.x

D'Amici GM, 2012, Red blood cell storage in SAGM and AS3: a comparison through the membrane two‐dimensional electrophoresis proteome, Blood Transfus, 10, s46

10.1111/j.1423-0410.2006.00778.x

10.1016/S0887-7963(99)80058-3

10.1111/j.1423-0410.1998.tb05421.x

10.1111/j.1537-2995.2011.03402.x

10.1111/j.1537-2995.2009.02555.x

Canadian Standards Association.CAN/CSA‐Z902‐10 Blood and Blood Components. 2010 edition. Mississauga (ON): Canadian Standards Association;2010.

10.1111/trf.12303

10.1155/2013/154838

10.1111/trf.12170

10.1111/trf.12489

10.1111/j.1537-2995.2012.03752.x

Webster J, 2008, Evaluation of the Canadian Blood Services red blood cell shipping container, Can J Med Lab Sci, 70, 167

10.1136/jcp.49.4.271

10.1053/tmrv.2002.29404

DiaSys Diagnostic Systems GmbH.ATP Hexokinase FS*. Holzheim Germany: DiaSys Diagnostic Systems GmbH;2004[cited 2013 Aug 26]. Available from:http://btclab.com/media/2674/atp‐4.pdf

Roche Diagnostics GmbH.2 3‐Diphosphoglycerate (2 3‐DPG) UV‐test for the determination of 2 3‐DPG in blood research samples. Mannheim Germany: Roche Diagnostics GmbH;2010[cited 2013 Aug 26]. Available from:https://cssportal.roche.com/LFR_PublicDocs/ras/10148334001_en_22.pdf

10.1016/0003-2697(73)90309-6

Guarnone R, 1995, Performance characteristics of Hemox‐Analyzer for assessment of the hemoglobin dissociation curve, Haematologica, 80, 426

Harmening DM, 1997, Clinical hematology and fundamentals of hemostasis, 606

10.1111/j.1423-0410.1975.tb02756.x

10.1111/j.1751-2824.2006.00048.x

10.1111/j.1537-2995.2006.00681.x

Thibault L, 2011, Red blood cell hemolysis at the end of storage: challenging the new standard, Transfusion, 51, 9A

10.1111/j.1537-2995.2010.02959.x

Hurtado C, 2000, Quality analysis of blood components obtained by automated buffy‐coat layer removal with a top & bottom system (Optipress (R)II), Haematologica, 85, 390

Korte D, 2004, Quality determinants of erythrocyte destined for transfusion, Cell Mol Biol (Noisy‐le‐grand), 50, 187

10.1016/S0887-7963(92)70166-7

10.1111/j.1423-0410.2008.01152.x

10.1111/j.1365-3148.2010.01025.x

Sparrow RL, 2012, Time to revisit red blood cell additive solutions and storage conditions: a role for “omics” analyses, Blood Transfus, 10, s7

10.1111/j.1423-0410.1989.tb04981.x

10.1111/j.1537-2995.2008.01667.x

10.1111/j.1365-3148.2008.00870.x

10.1056/NEJMoa070403

10.1016/j.tmrv.2011.07.003