A comparison study of haemolysis production in three contemporary centrifugal pumps

Perfusion (United Kingdom) - Tập 29 Số 5 - Trang 411-416 - 2014
Steve Bottrell1, Martin R. Bennett1, S Augustin1, Clarke A. Thuys1, Bradley Schultz1, Allison M. Horton1, Stephen Horton2,1
1Perfusion Department, Royal Children's Hospital, Melbourne, Victoria, Australia
2Department of Paediatrics, Melbourne University, Melbourne, Victoria, Australia

Tóm tắt

One challenge in providing extracorporeal circulation is to supply optimal flow while minimising adverse effects, such as haemolysis. To determine if the recent generation constrained vortex pumps with their inherent design improvements would lead to reduced red cell trauma, we undertook a study comparing three devices. Utilizing a simulated short-term ventricular assist circuit primed with whole human blood, we examined changes in plasma free haemoglobin values over a six-day period. The three pumps investigated were the Maquet Rotaflow, the Levitronix PediVAS and the Medos Deltastream DP3.This study demonstrated that all three pumps produced low levels of haemolysis and are suitable for use in a clinical environment. The Levitronix PediVAS was significantly less haemolytic than either the Rotaflow (p<0.05) or the DP3 (p<0.05). There was no significant difference in plasma free haemoglobin between the Rotaflow and the DP3 (p=0.71).

Từ khóa


Tài liệu tham khảo

Conrad S, 2012, ECMO. Extracorporeal cardiopulmonary support in critical care, 4, 102

10.1191/0267659104pf729oa

10.1097/01.PCC.0000163282.63992.13

10.1097/MAT.0b013e31821f2116

10.1177/026765910001500404

10.1182/blood-2012-11-451229

10.1016/j.jtcvs.2010.03.046

10.1016/j.jtcvs.2007.01.085

10.1016/j.healun.2007.10.015

10.1016/j.healun.2005.08.019

10.1016/j.healun.2005.11.458

10.1016/j.healun.2008.01.027

10.1097/MAT.0b013e3181904232

10.1016/j.healun.2009.04.015

10.1111/j.1525-1594.2006.00203.x

Levitronix Technologies. Bearingless pump technology. http://www.levitronix.com/en/Bearingless_Pumps.html (2010, accessed June 2013)

Schöb R. Centrifugal pump without bearings or seals. http://www.worldpumps.com (2002, Retrieved June 2013)

10.1191/0267659104pf702oa

10.1053/j.pcsu.2006.02.003

10.1046/j.1525-1594.2001.025005358.x

Medos Medizintechnik AG, 2013, Stolberg Germany MEDOS Medizintechnik AG

10.1097/MAT.0b013e3181be2f5c

10.1016/j.healun.2012.10.001

Petermann H, 2005, Strömungsmaschinen, 7

10.1016/S0006-3495(72)86085-5

10.1017/S0956792509007839

10.1111/j.1525-1594.2009.00875.x

10.1111/j.1525-1594.2004.07379.x

10.1111/j.1525-1594.2006.00231.x

10.1111/j.1525-1594.2007.00392.x