APSIC guide for prevention of Central Line Associated Bloodstream Infections (CLABSI)
Tóm tắt
This document is an executive summary of the APSIC Guide for Prevention of Central Line Associated Bloodstream Infections (CLABSI). It describes key evidence-based care components of the Central Line Insertion and Maintenance Bundles and its implementation using the quality improvement methodology, namely the Plan-Do-Study-Act (PDSA) methodology involving multidisciplinary process and stakeholders. Monitoring of improvement over time with timely feedback to stakeholders is a key component to ensure the success of implementing best practices. A surveillance program is recommended to monitor outcomes and adherence to evidence-based central line insertion and maintenance practices (compliance rate) and identify quality improvement opportunities and strategically targeting interventions for the reduction of CLABSI.
Tài liệu tham khảo
The Joint Commission. Preventing Central Line–Associated Bloodstream Infections: A Global Challenge, a Global Perspective. Oak Brook: Joint Commission Resources; 2012.
Pronovost P, Needham D, Berenholtz S, Frank J, et al. An intervention to decrease catheter-related bloodstream infections in the ICU. N Engl J Med. 2006;355(26):2725–32.
Datta P, Rani H, Chauhan R, Gombar S, Chander J. Health-care-associated infections: Risk factors and epidemiology from an intensive care unit in Northern India. Indian J Anaesth. 2014;58(1):30–5.
Fraenkel D, Rickard C, Thomas P, Faoagali J, George N, Ware R. A prospective, randomized trial of rifampicin-minocycline-coated and silver-platinum-carbon-impregnated central venous catheters. Crit Care Med. 2006;34(3):668–75.
Kim SH, Song KI, Chang JW, Kim SB, Sung SA, Jo SK, et al. Prevention of uncuffed hemodialysis catheter-related bacteremia using an antibiotic lock technique: a prospective, randomized clinical trial. Kidney Int. 2006;69(1):161–4.
Richards B, Chaboyer W, Bladen T, Schluter PJ. Effect of central venous catheter type on infections: a prospective clinical trial. J Hosp Infect. 2003;54(1):10–7.
Sheng WH, Ko WJ, Wang JT, Chang SC, Hsueh PR, Luh KT. Evaluation of antiseptic-impregnated central venous catheters for prevention of catheter-related infection in intensive care unit patients. Diagn Microbiol Infect Dis. 2000;38(1):1–5.
Yoshida J, Ishimaru T, Fujimoto M, Hirata N, Matsubara N, Koyanagi N. Risk factors for central venous catheter-related bloodstream infection: a 1073-patient study. J Infect Chemother. 2008;14(6):399–403.
Zhang P, Yuan J, Tan H, Lv R, Chen J. Successful prevention of cuffed hemodialysis catheter-related infection using an antibiotic lock technique by strictly catheter-restricted antibiotic lock solution method. Blood Purif. 2009;27(2):206–11.
Apisarnthanarak A, Greene MT, Kennedy EH, Khawcharoenporn T, Krein S, Saint S. National survey of practices to prevent healthcare-associated infections in Thailand: the role of safety culture and collaboratives. Infect Control Hosp Epidemiol. 2012;33(7):711–7. doi:10.1086/666330. Epub 2012 May 14.
Apisarnthanarak A, Khawcharoenporn T, Mundy LM. National survey of suboptimal and unnecessary practices for central line placement and management in Thailand. Am J Infect Control. 2013;41(2):e11–3. doi:10.1016/j.ajic.2012.07.019.
Jaggi N, Sissodia P. Repeated multimodal supervision programs to reduce the central line-associated bloodstream infection rates in an Indian corporate hospital. Healthcare Infection. 2014;19:53–8. http://dx.doi.org/10.1071/HI13030.
Jaggi N, Rodrigues C, Rosenthal VD, Todi SK, Shah S, Saini N, et al. Impact of an International Nosocomial Infection Control Consortium multidimensional approach on central line-associated bloodstream infection rates in adult intensive care units in eight cities in India. Int J Infect Dis. 2013;17(12):1218–24.
Jaggi N, Nirwan P, Naryana E, Kaur KP. The analysis and impact of three successive intervention programmes directed to reduce central line associated blood stream infections over a four year period in a tertiary care hospital in India. Antimicrobial Resistance and Infection Control. 2013;2 Suppl 1:2. doi:10.1186/2047-2994-2-S1-P2.
Parienti J, Mongardon N, Megarbane B, Mira J, Kalfon P, Gros A, et al. Intravascular complications of central venous catheterization by insertion site. N Engl J Med. 2015;373:1220–9. doi:10.1056/NEJMoa1500964.
Parienti JJ, Thirion M, Megarbane B, et al. Femoral vs jugular venous catheterization and risk of nosocomial events in adults requiring acute renal replacement therapy: a randomized controlled trial. JAMA. 2008;299:2413–22.
Nagashima G, Kikuchi T, Tsuyuzaki H, et al. To reduce catheter-related bloodstream infections: is the subclavian route better than the jugular route for central venous catheterization? J Infect Chemother. 2006;12:363–5.
Hind D, Calvert N, McWilliams R, et al. Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ. 2003;327:361.
Larson EL, Rackoff WR, Weiman M, et al. APIC guideline for handwashing and hand antisepsis in health care settings. Am J Infect Control. 1995;23:251–69.
WHO Guidelines on Hand Hygiene in Health Care: a Summary 2009.
Maki DG, Ringer M, Alvarado CJ. Prospective randomised trial of povidone-iodine, alcohol, and chlorhexidine for prevention of infection associated with central venous and arterial catheters. Lancet. 1991;338:339–43.
Chaiyakunapruk N, Veenstra DL, Lipsky BA, Saint S. Chlorhexidine compared with povidone-iodine solution for vascular catheter-site care: a meta-analysis. Ann Intern Med. 2002;136:792–801.
Raad II, Hohn DC, Gilbreath BJ, et al. Prevention of central venous catheter-related infections by using maximal sterile barrier precautions during insertion. Infect Control Hosp Epidemiol. 1994;15:231–8.
Lin TY, Lee CM, Wang FD, et al. Taiwan guidelines for prevention and control of intravascular catheter-related bloodstream infections. 2011.
O’Grady NP, Alexander M, Burns LA, et al. Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis. 2011;52(9):e162-93. doi:10.1093/cid/cir257.
Guidelines for the Prevention of Intravascular Catheter-Related Infections, CDC 2011 (available at: http://www.cdc.gov/hicpac/pdf/guidelines/bsi-guidelines-2011.pdf)
Guide to the eliminations of catheter–related bloodstream infections- An APIC guide 2009.
Getting Started Kit: Prevent Central Line Infections, Central Line Associated - Blood Stream Infections (CLA-BSI) Safer Healthcare Now! Campaign (SHN) 2009
Central line insertion and maintenance guidelines. Australian Commission on Safety and Quality in Health care 2012.
Camp-Sorrell D, editor. Access Device Guidelines: Recommendations for Nursing Practice and Education. 3rd ed. Pittsburgh: Oncology Nursing Society; 2011. Copyright 2011 by ONS. INS 2011 Infusion Nursing Standards of Practice.
Basic Infection Control And Prevention Plan for Outpatient Oncology Settings CDC December 2011
Guide to the Elimination of Infections in Hemodialysis, An APIC Guide 2010
NHMRC Australian Guidelines for the Prevention and Control of Infection in Healthcare. Commonwealth of Australia 2010.
JCI. 2012. Preventing Central Line–Associated Bloodstream Infections. A Global Challenge, A Global Perspective. Available from: www.jointcommission.org/assets/1/18/clabsi_monograph.pdf
CDC. 2011 Guidelines for the Prevention of Intravascular Catheter-Related Infections. Available from: http://www.cdc.gov/hicpac/pdf/guidelines/bsi-guidelines-2011.pdf
Guide H-t. Prevent Central Line-Associated Bloodstream Infections. Cambridge: Institute for Healthcare Improvement; 2012.
Weaver SJ, Lubomksi LH, Wilson RF, Pfoh ER, Martinez KA, Dy SM. Promoting a culture of safety as a patient safety strategy: a systematic review. Ann Intern Med. 2013;158(5 pt 2):369–74.
Hatler CW, Mast D, Corderella J, et al. Using evidence and process improvement strategies to enhance healthcare outcomes for the critically ill: a pilot project. Am J Crit Care. 2006;15(6):549–55.
Warye KL, Murphy DM. Targeting zero health care–associated infections. Am J Infect Control. 2008;36:683–4.
Gilbert GL, Cheung PY, Kerridge IB. Infection control, ethics and accountability. Med J Aust. 2009;190(12):696–8.
Marschall J, Mermel LA, Fakih M, et al. Strategies to Prevent Central Line–Associated Bloodstream Infections in Acute Care Hospitals: 2014 Update. Infect Control Hosp Epidemiol. 2014;35(7):753–71.
Garland JS, Alex CP, Mueller CD, et al. A randomized trial comparing povidone-iodine to a chlorhexidine gluconate-impregnated dressing for prevention of central venous catheter infections in neonates. Pediatrics. 2001;107(6):1431–6.
Spencer C, Orr D, Hallam S, Tillmanns E. Daily bathing with octenidine on an intensive care unit is associated with a lower carriage rate of meticillin-resistant Staphylococcus aureus. J Hosp Infect. 2013;83(2):156–9.
Timsit JF, Schwebel C, Bouadma L, Geffroy A, Garrouste-Orgeas M, Pease S, Herault MC, Haouache H, Calvino-Gunther S, Gestin B. Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial. JAMA. 2009;301:1231–41.
Tamma PD, Aucott SW, Milstone AM. Chlorhexidine use in the neonatal intensive care unit: results from a national survey. Infect Control Hosp Epidemiol. 2010;31(8):846–9.
Huang EY, Chen C, Abdullah F, et al. Strategies for the prevention of central venous catheter infections: an American Pediatric Surgical Association Outcomes and Clinical Trials Committee systematic review. J Pediatr Surg. 2011;46(10):2000–2011.
O’Grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, Lipsett PA, Masur H, Mermel LA, Pearson ML, Raad II, Randolph AG, Rupp ME, Saint S. Healthcare Infection Control Practices Advisory Committee (HICPAC). Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis. 2011;52(9):e162–93. Epub 2011 Apr 1.
Batra R, Cooper BS, Whiteley C, Patel AK, Wyncoll D, Edgeworth JD. Efficacy and limitation of a chlorhexidine-based decolonization strategy in preventing transmission of methicillin-resistant Staphylococcus aureus in an intensive care unit. Clin Infect Dis. 2010;50(2):210–7.
Lai NM, Chaiyakunapruk N, Lai NA, O’Riordan E, Pau WS, Saint S. Catheter impregnation, coating or bonding for reducing central venous catheter-related infections in adults. Cochrane Database Syst Rev. 2013;6:CD007878.
Hagau N, Studnicska D, Gavrus RL, Csipak G, Hagau R, Slavcovici AV. Central venous catheter colonization and catheter-related bloodstream infections in critically ill patients: a comparison between standard and silver-integrated catheters. Eur J Anaesthesiol. 2009;26:752–8.
Antonelli M, De Pascale G, Ranieri VM, Pelaia P, Tufano R, Piazza O, et al. Comparison of triple-lumen central venous catheters impregnated with silver nanoparticles (AgTive(R)) vs conventional catheters in intensive care unit patients. J Hosp Infect. 2012;82:101–7.
Weber JM, Sheridan RL, Fagan S, Ryan CM, Pasternack MS, Tompkins RG. Incidence of catheter-associated bloodstream infection after introduction of minocycline and rifampin antimicrobial-coated catheters in a pediatric burn population. J Burn Care Res. 2012;33:539–43.
Chelliah A, Heydon KH, Zaoutis TE, Rettig SL, Dominguez TE, Lin R, et al. Observational trial of antibiotic-coated central venous catheters in critically ill pediatric patients. Pediatr Infect Dis J. 2007;26:816–20.
Bertini G, Elia S, Ceciarini F, Dani C. Reduction of catheter-related bloodstream infections in preterm infants by the use of catheters with the AgION antimicrobial system. Early Hum Dev. 2013;89:21–5.
Zhao Y, Li Z, Zhang L, Yang J, Yang Y, Tang Y, et al. Citrate versus heparin lock for hemodialysis catheters: a systematic review and meta-analysis of randomized controlled trials. Am J Kidney Dis. 2014;63:479–90.
Yahav D, Rozen-Zvi B, Gafter-Gvili A, Leibovici L, Gafter U, Paul M. Antimicrobial lock solutions for the prevention of infections associated with intravascular catheters in patients undergoing hemodialysis: systematic review and meta-analysis of randomized, controlled trials. Clin Infect Dis. 2008;47:83–93.
Jaffer Y, Selby NM, Taal MW, Fluck RJ, McIntyre CW. A meta-analysis of hemodialysis catheter locking solutions in the prevention of catheter-related infection. Am J Kidney Dis. 2008;51:233–41.
Labriola L, Crott R, Jadoul M. Preventing haemodialysis catheter-related bacteraemia with an antimicrobial lock solution: a meta-analysis of prospective randomized trials. Nephrol Dial Transplant. 2008;23:1666–72.
Snaterse M, Ruger W, Scholte Op Reimer WJ, Lucas C. Antibiotic-based catheter lock solutions for prevention of catheter-related bloodstream infection: a systematic review of randomised controlled trials. J Hosp Infect. 2010;75:1–11.
Zacharioudakis IM, Zervou FN, Arvanitis M, Ziakas PD, Mermel LA, Mylonakis E. Antimicrobial lock solutions as a method to prevent central line-associated bloodstream infections: a meta-analysis of randomized controlled trials. Clin Infect Dis. 2014. doi:10.1093/cid/ciu671.
van de Wetering MD, van Woensel JB, Lawrie TA. Prophylactic antibiotics for preventing Gram positive infections associated with long-term central venous catheters in oncology patients. Cochrane Database Syst Rev. 2013;11:CD003295.
Catheter WM. Llubrication and fixation: interventions. Br J Nurs. 2013;22(10):566. 568-9.
Alekseyev S, Byrne M, Carpenter A, Franker C, Kidd C, Hulton L. Prolonging the life of a patient’s IV: an integrative review of intravenous securement devices. Medsurg Nurs. 2012;21(5):285–92.
Petree C, Wright DL, Sanders V, Killion JB. Reducing blood stream infections during catheter insertion. Radiol Technol. 2012;83(6):532–40.
Cotogni P, Pittiruti M, Barbero C, Monge T, Palmo A, Boggio Bertinet D. Catheter-related complications in cancer patients on home parenteral nutrition: a prospective study of over 51,000 catheter days. JPEN J Parenter Enteral Nutr. 2013;37(3):375–83.
Christopher C, Maki DG. The Promise of Novel Technology for the Prevention of Intravascular Device–Related Bloodstream Infection. Clin Infect Dis. 2002;34(10):1362–8. Epub 2002 Apr 17.
Simonova G, Rickard CM, Dunster KR, Smyth DJ, McMillan D, Fraser JF. Cyanoacrylate tissue adhesives - effective securement technique for intravascular catheters: in vitro testing of safety and feasibility. Anaesth Intensive Care. 2012;40(3):460–6.
Egan GM, Siskin GP, Weinmann 4th R, Galloway MM. A prospective postmarket study to evaluate the safety and efficacy of a new peripherally inserted central catheter stabilization system. J Infus Nurs. 2013;36(3):181–8.
Sundararajan K, Wills S, Chacko B, Kanabar G, O’Connor S, Deane A. Impact of delirium and suture-less securement on accidental vascular catheter removal in the ICU. Anaesth Intensive Care. 2014;42(4):473–9.
Rupp ME, Sholtz LA, Jourdan DR, et al. Outbreak of bloodstream infection temporally associated with the use of an intravascular needleless valve. Clin Infect Dis. 2007;44:1408–14.
Maragakis LL, Bradley KL, Song X, et al. Increased catheter-related bloodstream infection rates after the introduction of a new mechanical valve intravenous access port. Infect Control Hosp Epidemiol. 2006;27(1):67–70.
Mazher MA, Kallen A, Edwards JR, Donlan RM. An in vitro evaluation of disinfection protocols used for needleless connectors of central venous catheters. Lett Appl Microbiol. 2013;57(4):282–7. doi:10.1111/lam.12108. Epub 2013 Jun 7.
Pichler J, Soothill J, Hill S. Reduction of blood stream infections in children following a change to chlorhexidine disinfection of parenteral nutrition catheter connectors. Clin Nutr. 2014;33(1):85–9. doi:10.1016/j.clnu.2013.03.021. Epub 2013 Apr 10.
Casey AL, Karpanen TJ, Nightingale P, Cook M, Elliott TS. Microbiological comparison of a silver-coated and a non-coated needleless intravascular connector in clinical use. J Hosp Infect. 2012;80(4):299–303. doi:10.1016/j.jhin.2012.01.005. Epub 2012 Feb 17.
Menyhay SZ, Maki DG. Preventing central venous catheter-associated bloodstream infections: development of an antiseptic barrier cap for needleless connectors. Am J Infect Control. 2008;36(10):S174. doi:10.1016/j.ajic.2008.10.006. e1-5.
Sweet MA, Cumpston A, Briggs F, Craig M, Hamadani M. Impact of alcohol-impregnated port protectors and needleless neutral pressure connectors on central line-associated bloodstream infections and contamination of blood cultures in an inpatient oncology unit. Am J Infect Control. 2012;40(10):931–4. doi:10.1016/j.ajic.2012.01.025. Epub 2012 May 9.
Sandora TJ, Graham DA, Conway M, Dodson B, Potter-Bynoe G, Margossian SP. Impact of needleless connector change frequency on central line-associated bloodstream infection rate. Am J Infect Control. 2014;42(5):485–9. doi:10.1016/j.ajic.2014.01.022.
Ling ML, Apisarnthanarak A, Madriaga G. The burden of healthcare-associated infections in Southeast Asia: A systematic literature review and meta-analysis. Clinical Infectious Diseases 2015: civ095v1-civ095