Informed RESTORE: A method for robust estimation of diffusion tensor from low redundancy datasets in the presence of physiological noise artifacts

Magnetic Resonance in Medicine - Tập 68 Số 5 - Trang 1654-1663 - 2012
Lin‐Ching Chang1, Lindsay Walker2,3, Carlo Pierpaoli3
1Department of Electronic Engineering and Computer Science, The Catholic University of America, Washington, District of Columbia, USA
2Center for Neuroscience and Regenerative Medicine at the Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA
3National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, Maryland USA

Tóm tắt

AbstractPhysiological noise artifacts, especially those originating from cardiac pulsation and subject motion, are common in clinical Diffusion tensor‐MRI acquisitions. Previous works show that signal perturbations produced by artifacts can be severe and neglecting to account for their contribution can result in erroneous diffusion tensor values. The Robust Estimation of Tensors by Outlier Rejection (RESTORE) method has been shown to be an effective strategy for improving tensor estimation on a voxel‐by‐voxel basis in the presence of artifactual data points in diffusion‐weighted images. In this article, we address potential instabilities that may arise when using RESTORE and propose practical constraints to improve its usability. Moreover, we introduce a method, called informed RESTORE designed to remove physiological noise artifacts in datasets acquired with low redundancy (less than 30–40 diffusion‐weighted image volumes)—a condition in which the original RESTORE algorithm may converge to an incorrect solution. This new method is based on the notion that physiological noise is more likely to result in signal dropouts than signal increases. Results from both Monte Carlo simulation and clinical diffusion data indicate that informed RESTORE performs very well in removing physiological noise artifacts for low redundancy diffusion‐weighted image datasets. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.

Từ khóa


Tài liệu tham khảo

10.1093/med/9780195369779.003.0030

10.1002/mrm.1910370226

10.1006/jmrb.1994.1037

10.1002/mrm.22924

10.1093/med/9780195369779.003.0018

10.1002/mrm.22786

10.1016/j.mri.2010.06.022

10.1016/j.neuroimage.2010.06.014

10.1016/S1361-8415(02)00079-8

10.1002/mrm.20426

Chang LC, 2009, Making the robust tensor estimation approach: “RESTORE” more robust. In ISMRM 17th Annual Meeting and Exhibition,, 3557

10.1016/j.neuroimage.2010.08.048

10.1006/jmre.2000.2209

10.1002/(SICI)1522-2594(199909)42:3<515::AID-MRM14>3.0.CO;2-Q

10.1002/jmri.1107

10.1148/radiology.201.3.8939209

10.1006/jmrb.1996.0086

Cormen TH, 2009, Introduction to algorithms

10.1002/mrm.1910320508

10.1002/mrm.10184

Bevington P, 1969, Data reduction and error analysis for the physical sciences

10.1002/mrm.21111

PierpaoliC WalkerL IrfanogluMO BarnettA BasserPJ ChangL‐C KoayC PajevicS RohdeG SarllsJ WuM.TORTOISE: an integrated software package for processing of diffusion MRI data. In: ISMRM 18th annual meeting and exhibition Stockholm Sweden 2010.

10.1002/mrm.10677

10.1002/mrm.21890

10.1002/nbm.1543

Wu M, 2008, Comparison of EPI distortion correction methods in diffusion tensor MRI using a novel framework, Int Conf Med Image Comput Comput Assist Interv, 11, 321

10.1002/(SICI)1522-2594(199909)42:3<526::AID-MRM15>3.0.CO;2-J

NayakA WalkerL PierpaoliC BDCG. Quality assessment in a DTI multicenter study. In: ISMRM 19th annual meeting and exhibition Montreal Canada 2011. p2342.

PierpaoliC MarencoS RohdeGK JonesDK BarnettAS.Analyzing the contribution of cardiac pulsation to the variability of quantities derived from the diffusion tensor. In: ISMRM 11th annual meeting and exhibition Toronto Ontario Canada 2003. pm70.

Barnett V, 1985, Outliers in statistical data

10.1016/j.mri.2009.01.001

10.1002/mrm.22258

10.1002/mrm.10268

10.1002/hbm.10062