A patch type non-enzymatic biosensor based on 3D SUS micro-needle electrode array for minimally invasive continuous glucose monitoring

Earthquake Spectra - Tập 222 - Trang 1144-1151 - 2016
Su Jin Lee1, Hyo Sang Yoon1, Xing Xuan1, Jae Y. Park1, Seung-Joon Paik2, Mark G. Allen2
1Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowon-gu, Seoul 139-701, Republic of Korea
2School of Electrical and Computer Engineering, Georgia Institute of Technology, GA, USA

Tài liệu tham khảo

Prehn, 2012, A non-enzymatic glucose sensor based on the use of gold micropillar array electrodes, J. Electrochem. Soc., 159, F134, 10.1149/2.018206jes Lee, 2013, A micro-fabricated non-enzymatic urine glucose sensor using nafion coated nanoporous Pt composite electrodes, IEEE Sens., 746 Park, 2012, Nonenzymatic continuous glucose monitoring in human whole blood using electrified nanoporous Pt, Biosens. Bioelectron., 31, 284, 10.1016/j.bios.2011.10.033 Chetty, 2008, The effect of continuous subcutaneous glucose monitoring (CGMS) versus intermittent whole blood finger-stick glucose monitoring (SBGM) on hemoglobin A1c (HBA1c) levels in Type I diabetic patients: A systematic review, Diabetes Res. Clin. Pract., 81, 79, 10.1016/j.diabres.2008.02.014 Pickup, 2005, In vivo glucose monitoring: the clinical reality and the promise, Biosens. Bioelectron., 20, 1897, 10.1016/j.bios.2004.08.016 Cengiz, 2009, A tale of two compartments: interstitial versus blood glucose monitoring, Diabetes Technol. Ther., 11, s11, 10.1089/dia.2009.0002 Vaddiraju, 2010, Technologies for continuous glucose monitoring: current problems and future promises, J. Diabetes Sci. Technol., 4, 1540, 10.1177/193229681000400632 Wang, 2013, Non-enzymatic electrochemical sensing of glucose, Microchim. Acta, 180, 161, 10.1007/s00604-012-0923-1 Park, 2006, Electrochemical non-enzymatic glucose sensors, Anal. Chim. Acta, 556, 46, 10.1016/j.aca.2005.05.080 Kung, 2014, Single layer of nickel hydroxide nanoparticles covered on a porous Ni foam and its application for highly sensitive non-enzymatic glucose sensor, Sens. Actuators B Chem., 204, 159, 10.1016/j.snb.2014.07.102 Shervedani, 2014, Prickly nickel nanowires grown on Cu substrate as a supersensitive enzyme-free electrochemical glucose sensor, Sens. Actuators B Chem., 204, 783, 10.1016/j.snb.2014.08.033 El-Laboudi, 2013, Use of microneedle array devices for continuous glucose monitoring: a review, Diabetes Technol. Ther., 15, 101, 10.1089/dia.2012.0188 Norman, 2014, Microneedle patches: usability and acceptability for self-vaccination against influenza, Vaccine, 32, 1856, 10.1016/j.vaccine.2014.01.076 Harvey, 2011, Microneedle-based intradermal delivery enables rapid lymphatic uptake and distribution of protein drugs, Pharm. Res., 28, 107, 10.1007/s11095-010-0123-9 Gupta, 2011, Kinetics of skin resealing after insertion of microneedles in human subjects, J. Control Release, 154, 148, 10.1016/j.jconrel.2011.05.021 Davis, 2004, Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force, J. Biomech., 37, 1155, 10.1016/j.jbiomech.2003.12.010 Wang, 2001, Glucose biosensors: 40 years of advances and challenges, Electroanalysis, 13, 983, 10.1002/1521-4109(200108)13:12<983::AID-ELAN983>3.0.CO;2-# Piechotta, 2005, Novel micromachined silicon sensor for continuous glucose monitoring, Biosens. Bioelectron., 21, 802, 10.1016/j.bios.2005.02.008 Lee, 2008, Fully packaged nonenzymatic glucose microsensors with nanoporous platinum electrodes for anti-fouling, IEEE Sens. J., 8, 1922, 10.1109/JSEN.2008.2006697 Park, 2012, Nonenzymatic continuous glucose monitoring in human whole blood using electrified nanoporous Pt, Biosens. Bioelectron., 31, 284, 10.1016/j.bios.2011.10.033 Trasatti, 1991, Real surface area measurements in electrochemistry, Pure Appl. Chem., 63, 711, 10.1351/pac199163050711 Lee, 2009, Flexible enzyme free glucose micro-sensor for continuous monitoring applications, Transducers, 1806 Ernst, 1979, The electrooxidation of glucose in phosphate buffer solutions, J. Electroanal. Chem., 100, 173, 10.1016/S0022-0728(79)80159-X Rossetti, 2010, Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices, Sensors, 10, 10936, 10.3390/s101210936 Bailey, 2009, New features and performance of a next-generation SEVEN-day continuous glucose monitoring system with short lag time, Diabet. Technol. Ther., 11, 749, 10.1089/dia.2009.0075 Garg, 2009, Time lag characterization of two continuous glucose monitoring systems, Diabetes Res. Clin. Pract., 1, S11 Nichols, 2013, Biocompatible materials for continuous glucose monitoring devices, J. Am. Chem. Soc., 113, 2528