Motion‐robust and blood‐suppressed M1‐optimized diffusion MR imaging of the liver

Magnetic Resonance in Medicine - Tập 82 Số 1 - Trang 302-311 - 2019
Yuxin Zhang1,2, Óscar Peña‐Nogales2,3, James H. Holmes2, Diego Hernando1,2
1Department of Medical Physics, University of Wisconsin—Madison, Madison, Wisconsin
2Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin
3Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain

Tóm tắt

PurposeTo develop motion‐robust, blood‐suppressed diffusion‐weighted imaging (DWI) of the liver with optimized diffusion encoding waveforms and evaluate the accuracy and reproducibility of quantitative apparent diffusion coefficient (ADC) measurements.MethodsA novel approach for the design of diffusion weighting waveforms, termed M1‐optimized diffusion imaging (MODI), is proposed. MODI includes an echo time‐optimized motion‐robust diffusion weighting gradient waveform design, with a small nonzero first‐moment motion sensitivity (M1) value to enable blood signal suppression. Experiments were performed in eight healthy volunteers and five patient volunteers. In each case, DW images and ADC maps were compared between acquisitions using standard monopolar waveforms, motion moment‐nulled (M1‐nulled and M1–M2‐nulled) waveforms, and the proposed MODI approach.ResultsHealthy volunteer experiments using MODI showed no significant ADC bias in the left lobe relative to the right lobe (p < .05) demonstrating robustness to cardiac motion, and no significant ADC bias with respect to monopolar‐based ADC measured in the right lobe (p < .05), demonstrating blood signal suppression. In contrast, monopolar‐based ADC showed significant bias in the left lobe relative to the right lobe (p < .01) due to its sensitivity to motion, and both M1‐nulled and M1–M2‐nulled‐based ADC showed significant bias (p < .01) due to the lack of blood suppression. Preliminary patient results also suggest MODI may enable improved visualization and quantitative assessment of lesions throughout the entire liver.ConclusionsThis novel method for diffusion gradient waveform design enables DWI of the liver with high robustness to motion and suppression of blood signals, overcoming the limitations of conventional monopolar waveforms and moment‐nulled waveforms, respectively.

Từ khóa


Tài liệu tham khảo

10.2214/AJR.06.1403

10.1002/mrm.25035

10.1002/jmri.21227

10.1002/mrm.26128

10.1002/mrm.24563

10.1007/s10334-009-0183-1

10.1002/jmri.1880060614

10.1002/mrm.1910320313

10.1002/mrm.26166

10.1002/mrm.27462

10.1002/mrm.26709

MoulinK AliottaE EnnisD.Efficient IVIM of the liver using convex optimized diffusion encoding waveforms with variable flow encoding strengths. In Proceedings of the 25th Annual Meeting of ISMRM Honolulu HI 2017.

VanAT CervantesB OginoT et al.Partial velocity‐compensated diffusion encoding for combined motion compensation and residual vessel signal suppression in liver DWI. In Proceedings of the 26th Annual Meeting of ISMRM Paris France;2018.

10.1002/cmr.a.21223

10.1007/s00330-010-2017-y

10.1002/jmri.24946

10.1002/jmri.23796

10.1007/s10334-007-0084-0

10.1148/radiol.09090021

10.2214/ajr.173.2.10430143

10.1007/s00330-007-0798-4

10.1007/s00330-007-0785-9

10.1016/j.ejro.2015.08.001

10.1016/j.ejrad.2014.09.003

10.1148/radiographics.19.2.g99mr03373

TakaharaT ZwanenburgJ VisserF et al.Fat suppression with slice‐selection gradient reversal (SSGR) revisited. In Proceedings of the 17th Annual Meeting of ISMRM Honolulu HI 2009.