T2 quantification for improved detection of myocardial edema

Journal of Cardiovascular Magnetic Resonance - Tập 11 - Trang 1-13 - 2009
Shivraman Giri1,2, Yiu-Cho Chung3, Ali Merchant4, Georgeta Mihai2, Sanjay Rajagopalan2,4, Subha V Raman2,4, Orlando P Simonetti1,2,4,5
1Department of Biomedical Engineering, The Ohio State University, Columbus, USA
2Dorothy M. Davis Heart & Lung Research Institute, The Ohio State University, Columbus, USA
3Siemens Healthcare USA
4Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University, Columbus, USA
5Department of Radiology, The Ohio State University, Columbus, USA

Tóm tắt

T2-Weighted (T2W) magnetic resonance imaging (MRI) pulse sequences have been used to detect edema in patients with acute myocardial infarction and differentiate acute from chronic infarction. T2W sequences have suffered from several problems including (i) signal intensity variability caused by phased array coils, (ii) high signal from slow moving ventricular chamber blood that can mimic and mask elevated T2 in sub-endocardial myocardium, (iii) motion artifacts, and (iv) the subjective nature of T2W image interpretation. In this work we demonstrate the advantages of a quantitative T2 mapping technique to accurately and reliably detect regions of edematous myocardial tissue without the limitations of qualitative T2W imaging. Methods of T2 mapping were evaluated on phantoms; the best of these protocols was then optimized for in vivo imaging. The optimized protocol was used to study the spatial, view-dependent, and inter-subject variability and motion sensitivity in healthy subjects. Using the insights gained from this, the utility of T2 mapping was demonstrated in a porcine model of acute myocardial infarction (AMI) and in three patients with AMI. T2-prepared SSFP demonstrated greater accuracy in estimating the T2 of phantoms than multi-echo turbo spin echo. The T2 of human myocardium was found to be 52.18 ± 3.4 ms (range: 48.96 ms to 55.67 ms), with variability between subjects unrelated to heart rate. Unlike T2W images, T2 maps did not show any signal variation due to the variable sensitivity of phased array coils and were insensitive to cardiac motion. In the three pigs and three patients with AMI, the T2 of the infarcted region was significantly higher than that of remote myocardium. Quantitative T2 mapping addresses the well-known problems associated with T2W imaging of the heart and offers the potential for increased accuracy in the detection of myocardial edema.

Tài liệu tham khảo

Higgins CB, Herfkens R, Lipton MJ, Sievers R, Sheldon P, Kaufman L, Crooks LE: Nuclear magnetic resonance imaging of acute myocardial infarction in dogs: alterations in magnetic relaxation times. Am J Cardiol. 1983, 52: 184-188. 10.1016/0002-9149(83)90093-0. Abdel-Aty H, Cocker M, Meek C, Tyberg JV, Friedrich MG: Edema as a very early marker for acute myocardial ischemia: a cardiovascular magnetic resonance study. J Am Coll Cardiol. 2009, 53: 1194-1201. 10.1016/j.jacc.2008.10.065. Aletras AH, Tilak GS, Natanzon A, Hsu LY, Gonzalez FM, Hoyt RF, Arai AE: Retrospective determination of the area at risk for reperfused acute myocardial infarction with T2-weighted cardiac magnetic resonance imaging: histopathological and displacement encoding with stimulated echoes (DENSE) functional validations. Circulation. 2006, 113: 1865-1870. 10.1161/CIRCULATIONAHA.105.576025. Tilak GS, Hsu LY, Hoyt RF, Arai AE, Aletras AH: In vivo T2-weighted magnetic resonance imaging can accurately determine the ischemic area at risk for 2-day-old nonreperfused myocardial infarction. Invest Radiol. 2008, 43: 7-15. 10.1097/RLI.0b013e3181558822. Abdel-Aty H, Zagrosek A, Schulz-Menger J, Taylor AJ, Messroghli D, Kumar A, Gross M, Dietz R, Friedrich MG: Delayed enhancement and T2-weighted cardiovascular magnetic resonance imaging differentiate acute from chronic myocardial infarction. Circulation. 2004, 109: 2411-2416. 10.1161/01.CIR.0000127428.10985.C6. Cury RC, Shash K, Nagurney JT, Rosito G, Shapiro MD, Nomura CH, Abbara S, Bamberg F, Ferencik M, Schmidt EJ, Brown DF, Hoffmann U, Brady TJ: Cardiac Magnetic Resonance With T2-Weighted Imaging Improves Detection of Patients With Acute Coronary Syndrome in the Emergency Department. Circulation. 2008, 118 (8): 837-44. 10.1161/CIRCULATIONAHA.107.740597. Friedrich MG, Abdel-Aty H, Taylor A, Schulz-Menger J, Messroghli D, Dietz R: The salvaged area at risk in reperfused acute myocardial infarction as visualized by cardiovascular magnetic resonance. J Am Coll Cardiol. 2008, 51: 1581-1587. 10.1016/j.jacc.2008.01.019. Friedrich MG, Sechtem U, Schulz-Menger J, Holmvang G, Alakija P, Cooper LT, White JA, Abdel-Aty H, Gutberlet M, Prasad S, Aletras A, Laissy JP, Paterson I, Filipchuk NG, Kumar A, Pauschinger M, Liu P: International Consensus Group on Cardiovascular Magnetic Resonance in Myocarditis: Cardiovascular magnetic resonance in myocarditis: A JACC White Paper. J Am Coll Cardiol. 2009, 53: 1475-1487. 10.1016/j.jacc.2009.02.007. Butler CR, Thompson R, Haykowsky M, Toma M, Paterson I: Cardiovascular magnetic resonance in the diagnosis of acute heart transplant rejection: a review. J Cardiovasc Magn Reson. 2009, 11: 7-10.1186/1532-429X-11-7. Simonetti OP, Finn JP, White RD, Laub G, Henry DA: "Black blood" T2-weighted inversion-recovery MR imaging of the heart. Radiology. 1996, 199: 49-57. Abdel-Aty H, Simonetti O, Friedrich M: T2-weighted cardiovascular magnetic resonance imaging. J Magn Reson Imaging. 2007, 26: 452-459. 10.1002/jmri.21028. Arai AE: Using magnetic resonance imaging to characterize recent myocardial injury: utility in acute coronary syndrome and other clinical scenarios. Circulation. 2008, 118: 795-796. 10.1161/CIRCULATIONAHA.108.797373. Pennell D: Myocardial salvage: retrospection, resolution, and radio waves. Circulation. 2006, 113: 1821-1823. 10.1161/CIRCULATIONAHA.105.618942. Aletras AH, Kellman P, Derbyshire JA, Arai AE: ACUT2E TSE-SSFP: a hybrid method for T2-weighted imaging of edema in the heart. Magn Reson Med. 2008, 59: 229-235. 10.1002/mrm.21490. Kellman P, Aletras AH, Mancini C, McVeigh ER, Arai AE: T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo. Magn Reson Med. 2007, 57: 891-897. 10.1002/mrm.21215. Huang TY, Liu YJ, Stemmer A, Poncelet BP: T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence. Magn Reson Med. 2007, 57: 960-966. 10.1002/mrm.21208. Blume U, Lockie T, Stehning C, Sinclair S, Uribe S, Razavi R, Schaeffter T: Interleaved T(1) and T(2) relaxation time mapping for cardiac applications. J Magn Reson Imaging. 2009, 29: 480-487. 10.1002/jmri.21652. Brittain JH, Hu BS, Wright GA, Meyer CH, Macovski A, Nishimura DG: Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med. 1995, 33: 689-696. 10.1002/mrm.1910330515. Deshpande VS, Chung YC, Zhang Q, Shea SM, Li D: Reduction of transient signal oscillations in true-FISP using a linear flip angle series magnetization preparation. Magn Reson Med. 2003, 49: 151-157. 10.1002/mrm.10337. Deshpande VS, Shea SM, Laub G, Simonetti OP, Finn JP, Li D: 3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries. Magn Reson Med. 2001, 46: 494-502. 10.1002/mrm.1219. Kraft KA, Fatouros PP, Clarke GD, Kishore PR: An MRI phantom material for quantitative relaxometry. Magn Reson Med. 1987, 5: 555-562. 10.1002/mrm.1910050606. Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, Pennell DJ, Rumberger JA, Ryan T, Verani MS: Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002, 105: 539-542. 10.1161/hc0402.102975. Simonetti OP, Kim RJ, Fieno DS, Hillenbrand HB, Wu E, Bundy JM, Finn JP, Judd RM: An improved MR imaging technique for the visualization of myocardial infarction. Radiology. 2001, 218: 215-223. Foltz WD, Yang Y, Graham JJ, Detsky JS, Wright GA, Dick AJ: MRI relaxation fluctuations in acute reperfused hemorrhagic infarction. Magn Reson Med. 2006, 56: 1311-1319. 10.1002/mrm.21079. Keegan J, Gatehouse PD, Prasad SK, Firmin DN: Improved turbo spin-echo imaging of the heart with motion-tracking. J Magn Reson Imaging. 2006, 24: 563-570. 10.1002/jmri.20655. Scott AD, Keegan J, Firmin DN: Motion in cardiovascular MR imaging. Radiology. 2009, 250: 331-351. 10.1148/radiol.2502071998. Abdel-Aty H, Boye P, Zagrosek A, Wassmuth R, Kumar A, Messroghli D, Bock P, Dietz R, Friedrich MG, Schulz-Menger J: Diagnostic performance of cardiovascular magnetic resonance in patients with suspected acute myocarditis: comparison of different approaches. J Am Coll Cardiol. 2005, 45: 1815-1822. 10.1016/j.jacc.2004.11.069. Higgins CB, Lanzer P, Stark D, Botvinick E, Schiller NB, Crooks L, Kaufman L, Lipton MJ: Imaging by nuclear magnetic resonance in patients with chronic ischemic heart disease. Circulation. 1984, 69: 523-531. McNamara MT, Higgins CB, Schechtmann N, Botvinick E, Lipton MJ, Chatterjee K, Amparo EG: Detection and characterization of acute myocardial infarction in man with use of gated magnetic resonance. Circulation. 1985, 71: 717-724. Cocker M, Strohm O, Smith D, Butler C, Belenkie I, Meeuwisse W, Friedrich M: Sub-clinical systolic dysfunction with persistent myocardial edema and inflammation in elite high-endurance athletes with common colds: a cardiovascular magnetic resonance study. J Cardiovasc Magn Reson. 2009, 11: O3-10.1186/1532-429X-11-S1-O3. Patten C, Meyer RA, Fleckenstein JL: T2 mapping of muscle. Semin Musculoskelet Radiol. 2003, 7: 297-305. 10.1055/s-2004-815677. Reid RW, Foley JM, Jayaraman RC, Prior BM, Meyer RA: Effect of aerobic capacity on the T(2) increase in exercised skeletal muscle. J Appl Physiol. 2001, 90: 897-902. Sparrow P, Amirabadi A, Sussman MS, Paul N, Merchant N: Quantitative assessment of myocardial T2 relaxation times in cardiac amyloidosis. J Magn Reson Imaging. 2009, 30: 942-946. 10.1002/jmri.21918. MacFall JR, Riederer SJ, Wang HZ: An analysis of noise propagation in computed T2, pseudodensity, and synthetic spin-echo images. Med Phys. 1986, 13: 285-292. 10.1118/1.595956.