New parameters in assessment of human donor corneal stroma

Acta Ophthalmologica - Tập 95 Số 4 - 2017
Marie Borderie1,2, Kate Grieve1,2, Kristina Irsch3,1,2, Djida Ghoubay1,2, Cristina Georgeon1,2, Céline de Sousa4, L. Laroche1,2, Vincent Borderie1,2
1Quinze-Vingts National Ophthalmology Hospital, Paris VI University, Paris, France
2Vision Institute/CIC 1423, UMR_S 968/INSERM, U968/CHNO/CNRS, UMR_7210, UPMC University Paris 06, Paris, France
3Laboratory of Ophthalmic Instrument Development, The Wilmer Eye Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
4Tissue Bank, French Blood Establishment, Paris, Ile-de-France, France

Tóm tắt

AbstractPurpose

To provide quantitative parameters for assessment of human donor corneal stroma by imaging stromal features of diseased and normal human corneas with full‐field optical coherence microscopy (FFOCM), using confocal microscopy (CM) and histology as reference techniques.

Methods

Bowman's layer (BL) thickness and keratocyte density were assessed ex vivo in 23 human donor corneas and 27 human pathological corneas (keratoconus and other corneal disorders) with FFOCM, CM and histology. Stromal backscattering was assessed with FFOCM. Additionally, 10 normal human corneas were assessed in vivo with CM.

Results

In FFOCM, the logarithm of the normalized stromal reflectivity was a linear function of stromal depth (R2 = 0.95) in human donor corneas. Compared with keratoconus corneas, human donor corneas featured higher BL thickness (p = 0.0014) with lower coefficient of variation (BL‐COV; p = 0.0002), and linear logarithmic stromal reflectivity with depth (higher R2, p = 0.0001). Compared with other corneal disorders, human donor corneas featured lower BL‐COV (p = 0.012) and higher R2 (p = 0.0001). Using the 95% confidence limits of the human donor cornea group, BL thickness < 6.5 μm (sensitivity, 57%; specificity, 100%), BL‐COV > 18.6% (79%; 100%) and R2 < 0.94 (93%; 71%) were revealed as indictors of abnormal cornea. In CM, keratocyte density decreased with stromal depth (r = −0.56). The mean overall keratocyte density (cells/mm2) was 205 in human donor corneas, 244 in keratoconus, 176 in other corneal disorders and 386 in normal corneas.

Conclusion

Full‐field optical coherence microscopy (FFOCM) provides precise and reliable parameters for non‐invasive assessment of human donor corneal stroma during storage, enabling detection of stromal disorders that could impair the results of keratoplasty.

Từ khóa


Tài liệu tham khảo

10.1117/1.2764461

10.1016/S0161-6420(99)00002-0

10.1016/j.ajo.2008.06.034

10.1016/j.ajo.2010.11.020

10.1155/2013/397680

10.1364/OL.23.000244

10.1167/iovs.13-12437

10.1097/00003226-199703000-00015

10.1034/j.1600-0420.1998.760206.x

10.1136/bjo.82.4.382

10.1016/j.ajo.2011.01.007

10.1016/j.ophtha.2011.07.057

10.1097/ICO.0b013e318285c8b4

10.1016/j.ophtha.2005.01.024

10.1016/j.ophtha.2010.06.005

10.1136/bjo.85.7.788

10.1097/00003226-200003000-00006

10.1364/AO.41.000805

10.1016/S0002-9394(02)01698-7

10.1016/j.ophtha.2015.04.031

10.1007/s00417-014-2812-2

10.1111/j.1755-3768.2012.02519.x

Ghouali W, 2014, Full‐field optical coherence tomography of human donor and pathological corneas, Curr Eye Res, 24, 1

10.1167/iovs.04-0584

10.1016/j.exer.2010.06.021

10.1007/s00347-004-1083-4

10.1364/BOE.2.002905

Komuro A, 1999, Cell death during corneal storage at 4 degrees C, Invest Ophthalmol Vis Sci, 40, 2827

10.1016/j.ajo.2011.01.017

10.1016/j.ophtha.2007.04.067

10.1117/1.3486544

10.3109/02713689409042412

10.1016/j.ajo.2013.05.043

Patel S, 2001, Normal human keratocyte density and corneal thickness measurement by using confocal microscopy in vivo, Invest Ophthalmol Vis Sci, 42, 333

10.1097/ICO.0b013e31825ec44e

10.1016/j.ophtha.2013.05.027

10.1016/S0002-9394(02)01523-4

Tisdale AS, 1998, Development of the anchoring structures of the epithelium in rabbit and human fetal corneas, Invest Ophthalmol Vis Sci, 29, 727

10.1016/S0002-9394(98)00067-1

10.1167/iovs.04-0096