A functional electrical stimulation system for human walking inspired by reflexive control principles

Lin Meng1,2, Bernd Porr2, Catherine Macleod1, H. Gollee2
1Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
2Division of Biomedical Engineering, University of Glasgow, Glasgow, UK

Tóm tắt

This study presents an innovative multichannel functional electrical stimulation gait-assist system which employs a well-established purely reflexive control algorithm, previously tested in a series of bipedal walking robots. In these robots, ground contact information was used to activate motors in the legs, generating a gait cycle similar to that of humans. Rather than developing a sophisticated closed-loop functional electrical stimulation control strategy for stepping, we have instead utilised our simple reflexive model where muscle activation is induced through transfer functions which translate sensory signals, predominantly ground contact information, into motor actions. The functionality of the functional electrical stimulation system was tested by analysis of the gait function of seven healthy volunteers during functional electrical stimulation–assisted treadmill walking compared to unassisted walking. The results demonstrated that the system was successful in synchronising muscle activation throughout the gait cycle and was able to promote functional hip and ankle movements. Overall, the study demonstrates the potential of human-inspired robotic systems in the design of assistive devices for bipedal walking.

Từ khóa


Tài liệu tham khảo

10.1111/j.1525-1403.2009.00213.x

10.3182/20060920-3-FR-2912.00058

Chia N, Proceedings of the 37th annual international conference of the IEEE engineering in medicine and biology society (EMBC), 7159

10.1016/j.conengprac.2015.11.007

10.1016/j.jelekin.2014.09.008

Schouenborg J, 2011, Brain Mach Interface, 194, 215

10.1093/ptj/75.6.490

10.1109/JSEN.2004.823671

Liberson WT, 1961, Arch Phys Med Rehabil, 42, 101

10.1016/S0003-9993(97)90188-X

10.1016/B978-1-78242-101-6.00003-3

10.1016/0141-5425(92)90028-J

10.1007/BF02344765

10.1016/0141-5425(88)90099-4

10.1046/j.1525-1594.1999.06360.x

10.1093/ptj/63.7.1116

10.1080/003655000750045587

10.1109/86.867873

10.1016/j.jneumeth.2009.04.005

10.1016/S1350-4533(96)00030-6

10.1088/1741-2560/8/1/016009

10.1109/10.387193

10.1162/neco.2006.18.5.1156

10.1371/journal.pcbi.0030134

10.1371/journal.pone.0109959

Esfandyari J, Nuccio RD, Xu G. Solutions for mems sensor fusion, 2011, http://uk.mouser.com/applications/sensor_solutions_mems/

10.1109/7333.928571

10.1016/S0268-0033(98)00012-6

10.1152/physrev.1992.72.1.33

10.1016/S0165-0173(02)00201-1

10.1016/j.medengphy.2016.06.007

10.1109/TNSRE.2012.2185065

10.1016/j.simpat.2007.07.005

10.1109/TNSRE.2010.2052471

10.1161/STROKEAHA.110.599068

10.1186/1743-0003-8-47

10.1111/j.1525-1594.2004.07310.x

10.1161/STROKEAHA.109.560375

10.1109/TNSRE.2002.806832

10.1177/1545968311400092

10.1109/TNSRE.2006.870490

10.1152/jn.01002.2002

10.1113/expphysiol.2006.033886