PWM-less current controlled VSI-IM drive
7th International Workshop on Advanced Motion Control. Proceedings (Cat. No.02TH8623) - Trang 159-164
Tóm tắt
In this paper the PWM-less current controller for a voltage source inverter is discussed. The controller is of boundary layer type and a switching table realized. It allows employment of positive definite and also positive semi-definite vector function determining reaching dynamics. In its design the fact that the calculation of the stator voltage vectors from the d-q control components does not have a unique solution is exploited. This is considered as design freedom, which is further extended with logic control introducing preassigned-order switching according to the time scale separation of magnetization and the generation of torque currents. Zero voltage vectors are selected by finite automaton to the closest previous active voltage in order to minimize the inverter switching losses, reduce chattering and gives O(T/sub s//sup 2/) error type of current.
Từ khóa
#Pulse width modulation #Pulse width modulation inverters #Voltage control #Zero voltage switching #Employment #Stators #Logic design #Automatic generation control #Torque control #Magnetic switchingTài liệu tham khảo
pan, 1994, An improved hysteresis current controler for reducing switching frequency IEEE Trans on Power Electronics, 9, 97
gao, 1995, Discrete-time variable structure control systems IEEE Trans on Ind Electronics, 40, 45
hashimoto, 1988, Brushless servomotor control using variable structure approach, IEEE tarns IA, ia24, 160
lascu, 2000, A modifiead direct torque control for induction motor sensorless drive IEEE Trans on Industry Application, 36, 122
10.1109/41.370383
0, Escobar Discrete-time chattering free sliding mode control of servo drives, ISIE 2000 Mexico
10.1109/CCA.2001.973888
10.1109/9.847728
10.1109/41.793350
gao, 1993, Variable structure control of nonlinear systems: a new approach, IEEE Trans on Ind App, 40, 45
10.1109/5.301684
vast, 1998, Sensorless Vector and Direct Torque Control