A new method for measuring power output in a single leg extension: feasibility, reliability and validity

Springer Science and Business Media LLC - Tập 60 - Trang 385-390 - 1990
E. J. Bassey1, A. H. Short1
1Department of Physiology and Pharmacology, University of Nottingham Medical School, Queen's Medical Centre, Nottingham, UK

Tóm tắt

A method is described for measuring the explosive power of the leg in extension which has been found safe and acceptable for all age groups and levels of physical capability. The extension movement takes 0.25–0.40 s in a push through 0.165 m against a flat pedal. At the end of the push the leg is fully extended. The movement is made seated so that the forces are contained between the buttocks and the foot. The seat position is adjusted for leg length and the push is transmitted by a lever and chain to spin a flywheel. The gearing is such that resistance to the movement remains nearly constant throughout the extension. The final angular velocity of the flywheel is measured by an optoswitch and used to calculated the average leg extensor power (LEP) in the push. The reliability of the power measurement was evaluated in 46 subjects ranging in age from 20 to 86 years; they included medical students and geriatric day patients. They were tested on two occasions separated by a week. The maximal values on the first occasion (best of at least five trials) ranged from 30 to 300 W (mean ± 1 SD = 154 ± 88 W). There was no significant difference on re-test and the coefficient of variation was 9.4%. In a subgroup of 9 non-naive subjects who were measured by an experienced observer it was 6.3%. As expected, power was lower in women than in men and declined sharply with age. The sex difference was less when the values were expressed as power per body mass; a sharp age-related decline remained. The results from the LEP rig were compared with results obtained in the same subjects on the same occasion from similar pushes against an isokinetic dynamometer and two-legged jumps on a force plate. There was a highly significant correlation in both cases, Spearman's rank correlation (rho) = 0.73,P < 0.001,n = 16 subjects (age 27 ± 7.5 years) and rho = 0.86,P < 0.001,n = 13 subjects (age 39 ± 10.4 years) respectively.

Tài liệu tham khảo

Asmussen E, Bonde-Petersen F (1974) Storage of elastic energy in skeletal muscles in man. Acta Physiol Scand 91:385–392 Bassey EJ (1986) Demi-span as a measure of skeletal size. Ann Hum Biol 13:499–502 Bassey EJ, Bateman JC, Short AH (1989) A new short test of power output from the lower limbs in man. J Physiol (Lond) 409:21 P Bell DG, Jacobs I (1986) Electromechanical response times and rate of force development in males and females. Med Sci Sports Exerc 18:31–36 Bosco C, Komi PV (1980) Influence of ageing on the mechanical behaviour of leg extensor muscles. Eur J Appl Physiol 45:209–219 Bosco C, Luhtanen P, Komi PV (1983) A simple method for measurement of mechanical power in jumping. Eur J Appl Physiol 50:273–282 Davies CTM, Rennie M (1968) Human power output. Nature 217:770–771 Davies CTM, Wemyss-Holden J, Young K (1984) Measurement of short term power output: comparison between cycling and jumping. Ergonomics 27:285–296 Grieve DW, Linden J van der (1986) Force, velocity and power output of the human upper limb during horizontal pulls. Eur J Appl Physiol 55:425–430 Healy MJR (1958) Variations within individuals in human biology. Hum Biol 30:210 Hubley CL, Wells RP (1983) A work-energy approach to determine the individual joint contributions to vertical jump performance. Eur J Appl Physiol 50:247–254 Johnson T (1982) Age-related differences in isometric and dynamic strength and endurance. Phys Ther 7:985–989 Jones NL, McCartney N (1986) Influence of muscle power on aerobic performance and the effects of training. Acta Med Scand [Suppl] 711:115–122 Larsson L, Grimby G, Karlsson J (1979) Muscle strength and velocity of movement in relation to age and muscle morphology. J Appl Physiol 46:451–456 Makrides L, Heigenhauser GJF, McCartney N, Jones NL (1985) Maximal short term exercise capacity in healthy subjects aged 15–70 years. Clin Sci 69:197–205 Margaria R, Aghemo P, Rovelli E (1966) Measurement of muscular power (anaerobic) in man. J Appl Physiol 21:1662–1664 McCartney N, Heigenhauser GJF, Sargeant AJ, Jones NL (1983) A constant velocity cycle ergometer for the study of dynamic muscle function. J Appl Physiol 55:212–217 Morris AF, Clarke DH, Dainis A (1983) Time to maximal voluntary isometric contraction (MVC) for 5 different muscle groups in college adults. Res Q 54:163–168 Murray MP, Gardner GM, Mollinger LA, Sepic SB (1980) Strength of isometric and isokinetic contractions: knee muscles of men aged 20–56 years. Phys Ther 60:412–419 Murray MP, Duthie EH, Gambert SR, Sepic SB, Mollinger LA (1985) Age-related differences in knee muscle strength in normal women. J Gerontol 40:275–280 Patton JF, Duggan A (1987) An evaluation of tests of anaerobic power. Aviat Space Environ Med 58:237–242 Sargeant AJ (1987) Effect of muscle temperature on leg extension force and short-term power output in humans. Eur J Appl Physiol 56:693–698 Sargeant AJ, Hoinville E, Young A (1981) Maximum leg force and power output during short-term dynamic exercise. J Appl Physiol 51:1175–1182 Vandewalle H, Peres G, Heller J, Panel J, Monod H (1987) Force-velocity relationship and maximal power on a cycle ergometer. Eur J Appl Physiol 56:650–656 Wilkie DR (1950) The relation between force and velocity in human muscle. J Physiol (Lond) 110:249–280