18F-fluorodeoxyglucose positron emission tomography in the diagnosis of malignancy in patients with paraneoplastic neurological syndrome: a systematic review and meta-analysis

European Journal of Nuclear Medicine - Tập 44 Số 9 - Trang 1575-1587 - 2017
García Vicente, Ana María1, Delgado-Bolton, Roberto C.2, Amo-Salas, Mariano3, López-Fidalgo, Jesús4, Caresia Aróztegui, Ana Paula5, García Garzón, José Ramón6, Orcajo Rincón, Javier7, García Velloso, María José8, de Arcocha Torres, María9, Alvárez Ruíz, Soledad10
1Nuclear Medicine Department, University General Hospital, Ciudad Real, Spain
2Department of Diagnostic Imaging (Radiology) and Nuclear Medicine, San Pedro Hospital and Centre for Biomedical Research of La Rioja (CIBIR), University of La Rioja, Logroño, Spain
3Department of Mathematics, University of Castilla-La Mancha, Ciudad Real, Spain
4Universidad de Navarra, ICS, Unidad de Estadística, Campus Universitario, Pamplona, Spain
5Nuclear Medicine Department, Parc Taulí Hospital Universitari, Sabadell, Spain
6Unitat PET/TC CETIR-ERESA, Barcelona, Spain
7Nuclear Medicine Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain
8Nuclear Medicine Department, Clínica Universidad de Navarra, Pamplona, Spain
9Nuclear Medicine Department, Hospital Universitario Marques de Valdecilla, Santander, Spain
10Nuclear Medicine Department, Hospital Universitario Miguel Servet, Zaragoza, Spain

Tóm tắt

The detection of occult cancer in patients suspected of having a paraneoplastic neurological syndrome (PNS) poses a diagnostic challenge. The aim of our study was to perform a systematic review and meta-analysis to assess the diagnostic performance of FDG PET for the detection of occult malignant disease responsible for PNS. A systematic review of the literature (MEDLINE, EMBASE, Cochrane, and DARE) was undertaken to identify studies published in any language. The search strategy was structured after addressing clinical questions regarding the validity or usefulness of the test, following the PICO framework. Inclusion criteria were studies involving patients with PNS in whom FDG PET was performed to detect malignancy, and which reported sufficient primary data to allow calculation of diagnostic accuracy parameters. When possible, a meta-analysis was performed to calculate the joint sensitivity, specificity, and detection rate for malignancy (with 95% confidence intervals [CIs]), as well as a subgroup analysis based on patient characteristics (antibodies, syndrome). The comprehensive literature search revealed 700 references. Sixteen studies met the inclusion criteria and were ultimately selected. Most of the studies were retrospective (12/16). For the quality assessment, the QUADAS-2 tool was applied to assess the risk of bias. Across 16 studies (793 patients), the joint sensitivity, specificity, and detection rate for malignancy with FDG PET were 0.87 (95% CI: 0.80–0.93), 0.86 (95% CI: 0.83–0.89), and 14.9% (95% CI: 11.5–18.7), respectively. The area under the curve (AUC) of the summary ROC curve was 0.917. Homogeneity of results was observed for sensitivity but not for specificity. Some of the individual studies showed large 95% CIs as a result of small sample size. The results of our meta-analysis reveal high diagnostic performance of FDG PET in the detection of malignancy responsible for PNS, not affected by the presence of onconeural antibodies or clinical characteristics.

Tài liệu tham khảo