Journal of The Institution of Engineers (India): Series B

Công bố khoa học tiêu biểu

* Dữ liệu chỉ mang tính chất tham khảo

Sắp xếp:  
Comparison of Anti-islanding Protection in Single- and Three-Phase Solar Grid-Connected String Inverters
Journal of The Institution of Engineers (India): Series B - - 2022
K. Jeykishan Kumar
New Routing Metrics for ADHOC Network Routing Protocols
Journal of The Institution of Engineers (India): Series B - Tập 95 - Trang 351-361 - 2014
P. C. Reddy
The performance and reliability of Internet is measured using different quantities. When the quantities measured are essential and have wide range of acceptance then they are called metrics. Performance metrics enable comparison and selection among the alternatives. In computer networks, metrics are used to evaluate an application, protocol etc. Routing in adhoc networks is nontrivial. Routing pro...... hiện toàn bộ
Optimum Bidding Strategy for Power Industry with Inelastic Demand using Water Cycle Algorithm
Journal of The Institution of Engineers (India): Series B - Tập 103 - Trang 929-937 - 2022
Monalisa Datta, Dipu Sarkar
In a restructuring power industry, the essential principle of every generation company is to find the optimum bidding at any trading period. For an ISO, bidding strategy is a very interesting job. It is a complicated challenge as demand and generation uncertainty to maximize the profit of the participant in the market. This paper suggests an efficient data bidding technique for the maximization of...... hiện toàn bộ
Usage Based Transmission Cost Allocation to Wheeling Transactions in Bilateral Markets
Journal of The Institution of Engineers (India): Series B - Tập 100 - Trang 23-31 - 2018
M. S. G. Smitha, P. V. Satyaramesh, P. Sujatha
Transmission cost allocation among market participants in restructuring of power industry has become an important task in view of bilateral transaction framework. This paper presents a usage based methodology of transmission cost allocation in deregulated power system under open access. A new methodology for allocating transmission cost to wheeling transactions considering Zbus and contractual obl...... hiện toàn bộ
An Enhanced Three-Level Voltage Switching State Scheme for Direct Torque Controlled Open End Winding Induction Motor
Journal of The Institution of Engineers (India): Series B - - 2018
Kunisetti V. Praveen Kumar, Thippiripati Vinay Kumar
Statistical Switching Overvoltages of 1200 kV UHV AC Transmission Line
Journal of The Institution of Engineers (India): Series B - Tập 103 - Trang 189-195 - 2021
Ramchandra Reddy Annadi, Chandra Sekhar Patsa
To transport large power over long distances to meet higher demands requires UHV AC transmission systems. In the insulation design of UHV AC power transmission systems, it is important to know the magnitude of switching overvoltages that may occur. The need to withstand the switching surges can affect the cost of a transmission system, and hence, an estimate of the switching overvoltages under var...... hiện toàn bộ
Digital Model of Railway Electric Traction Lines
Journal of The Institution of Engineers (India): Series B - Tập 98 - Trang 377-384 - 2016
Rachana Garg, Priya Mahajan, Parmod Kumar
The characteristic impedance and propagation constant define the behavior of signal propagation over the transmission lines. The digital model for railway traction lines which includes railway tracks is developed, using curve fitting technique in MATLAB. The sensitivity of this model has been computed with respect to frequency. The digital sensitivity values are compared with the values of analog ...... hiện toàn bộ
Transmission Line Fault Location Using PCA-Based Best-Fit Curve Analysis
Journal of The Institution of Engineers (India): Series B - Tập 102 - Trang 339-350 - 2020
Alok Mukherjee, Palash Kumar Kundu, Arabinda Das
The paper presents a principal component analysis (PCA)-based method for localization of various power system faults in a 150 km long single side fed transmission line using quarter-cycle pre-fault and half-cycle post-fault sending end line current signals. The proposed work uses fault signals of ten different types of seven intermediate locations along the length of the line to develop three-phas...... hiện toàn bộ
Control of Electric Spring: A Lead–Lag Compensated Approach
Journal of The Institution of Engineers (India): Series B - Tập 102 - Trang 469-476 - 2021
Mehul Dansinh Solanki, S. K. Joshi
Electric spring is a custom power device, primarily being used for the voltage stability/voltage regulation of a customer’s electrical installation. The idea of electric spring has primarily been derived from the concept of mechanical spring, to damp out the oscillations or variations in the voltage due to intermittency of renewable energy sources that are present in the distribution system. This ...... hiện toàn bộ
A Modified Zeta Based High Power Quality Rectifier for Low Voltage Battery Charging Applications
Journal of The Institution of Engineers (India): Series B - - Trang 1-14 - 2023
Jitendra Gupta, Bhim Singh
A single stage high power quality (HPQ) rectifier, comprising an extended step-down gain modified Zeta converter is realized in this work for low voltage E-2-wheelers (E2Ws), and E-3-wheelers (E3Ws) battery charging applications. The presented rectifier exhibts wide output range feature and therefore, setup of a universal charger for all classes of E2Ws/E3Ws with battery packs of 24–60 V ratings. ...... hiện toàn bộ