Evaluation of Pre-Operative Hip Range of Motion under General AnaesthesiaHIP International - Tập 23 Số 3 - Trang 298-302 - 2013
Takaaki Fujishiro, Shinya Hayashi, Noriyuki Kanzaki, Shingo Hashimoto, Masahiro Kurosaka, Taiki Kanno, Takeshi Masuda
Hip range of motion (ROM) may be an important pre-operative variable, however, measurement of hip ROM can be affected by various factors. The purposes of this study were to compare conventional pre-operative ROM measurements with those measurements obtained under general anaesthesia, and to better define the associations between pre-operative hip ROM, and demographic, functional, and diag...... hiện toàn bộ
Preliminary results of a 3D-printed acetabular component in the management of extensive defectsHIP International - Tập 28 Số 3 - Trang 266-271 - 2018
Mustafa Citak, Lilly Kochsiek, Thorsten Gehrke, Carl Haasper, Eduardo M. Suero, Hans Mau
Introduction:The treatment of extensive bone loss and massive acetabular defects can be compounded by several challenges and pitfalls. The survivorship following acetabular revision with extensive bone loss is still unsatisfactory. The goal of the present study was to analyse the outcomes of 3D-printed patient-specific acetabular components in the managem...... hiện toàn bộ
Trabecular Titanium acetabular cups in hip revision surgery: mid-term clinical and radiological outcomesHIP International - Tập 28 Số 2_suppl - Trang 61-65 - 2018
Federico De Meo, Giorgio Cacciola, Vittorio Bellotti, Antongiolio Bruschetta, Pietro Cavaliere
Introduction: Severe acetabular bone loss during revision hip arthroplasty can be restored with different surgical techniques. Best results have been observed using porous tantalum cementless cups. Trabecular Titanium (TT) cups were designed to reproduce the structure, mechanical and biological characteristics of trabecular bone. Few clinical studies have...... hiện toàn bộ
The Role of Arthroscopy in the Treatment of Groin Pain after Total HIP Arthroplasty: Our ExperienceHIP International - Tập 26 Số 1_suppl - Trang S28-S33 - 2016
Mattia Filanti, Chiara Carubbi, Nicolandrea Del Piccolo, Nicola Rani, Alessandro Mazzotta, Dante Dallari
Aim The purpose of the study was to present our arthroscopic surgical technique and the results in patient with pain after a hip replacement. Methods Between November 2009 and September 2011, 35 patients with groin pain after total hip arthroplasty (THA) were treated arthroscopically. The pati...... hiện toàn bộ
Anterior Iliopsoas Impingement due to a Malpositioned Acetabular Component - Effective Relief by Surgical Cup ReorientationHIP International - Tập 27 Số 2 - Trang 128-133 - 2017
Benjamin Schoof, Oliver Jakobs, Stefan Schmidl, Christian Lausmann, Florian Fensky, Johannes Beckmann, Thorsten Gehrke, Matthias Gebauer
Background Determining the aetiology of persistent pain following total hip arthroplasty (THA) can be challenging. Impingement of the iliopsoas muscle due to a malpositioned acetabular component after THA might be a potential cause of postoperative groin pain. Methods We retrospectively analys...... hiện toàn bộ
Clinical Predictors for Possible Failure after Total Hip ArthroplastyHIP International - Tập 26 Số 6 - Trang 531-536 - 2016
Tatsuya Sueyoshi, John B. Meding, Kenneth Davis, Wesley G. Lackey, Robert A. Malinzak, Merrill A. Ritter
Introduction With the rising number of total hip arthroplasties (THAs) each year, it is increasingly important for surgeons to have evidence-based information on which to determine how often patients should be examined postoperatively. The purpose of this research was to determine whether it is possible to identify – based on Harris Hip Score (HHS) – earl...... hiện toàn bộ
Dual Mobility Cups: An Effective Prosthesis in Revision Total Hip Arthroplasties for Preventing DislocationsHIP International - Tập 26 Số 1 - Trang 57-61 - 2016
Julio J. Jauregui, Todd P. Pierce, Randa K. Elmallah, Jeffrey J. Cherian, Ronald E. Delanois, Michael A. Mont
Purpose Postoperative dislocation is one of the most common complications following total hip arthroplasty (THA), and dual mobility articulations have been designed to provide greater hip stability. However, there are few studies that have assessed outcomes of these designs in revision THAs. Our purpose was to evaluate differences in dislocation rates, as...... hiện toàn bộ
Surface Replacement: The Hip Replacement of the Future?HIP International - Tập 8 Số 4 - Trang 187-207 - 1998
Harlan C. Amstutz, Edward A Sparling, P. Grigoris, Pat Campbell, Fred Dorey
Surface replacement is a significant development in the evolution of hip arthroplasty. Unlike conventional total hip arthroplasty, surface replacement does not require resection of the femoral head; thus, it presents a potentially effective, bone-conserving alternative to conventional replacements. Moreover, conversion to total hip replacement can be made readily, if necessary, with fewer ...... hiện toàn bộ
Greater Trochanteric Pain after Total Hip Arthroplasty: The Incidence, Clinical Outcome and Associated FactorsHIP International - Tập 16 Số 3 - Trang 202-206 - 2006
Arkan S. Sayed‐Noor, G.O. Sjödén
We evaluated any residual pain around the hip joint 11 to 23 months post-surgery in 172 consecutive patients who underwent total hip arthroplasty (THA) for primary or secondary osteoarthritis during 2002 at Sundsvall Hospital, Sweden.Patients with suspected greater trochanteric pain (GTP) were matched with controls from the same cohort. The two groups were assessed with th...... hiện toàn bộ