Which sample tube should be used for routine glucose determination?

Primary Care Diabetes - Tập 10 - Trang 227-232 - 2016
Graziella Bonetti1, Vanessa Cancelli1, Giulio Coccoli1, Giorgio Piccinelli1, Duilio Brugnoni1, Luigi Caimi1,2, Mariarosa Carta3
1Clinical Chemistry Laboratory, A.O. Spedali Civili, Brescia, Italy
2Department of Molecular and Translational Medicine, University of Brescia, Brescia, Italy
3Clinical Chemistry and Haematology Laboratory, San Bortolo Hospital, Vicenza, Italy

Tài liệu tham khảo

American Diabetes Association, 2015, Standards of Medical Care in Diabetes—2015, Diabetes Care, 38, S8, 10.2337/dc15-S005 World Health Organization, 2006 Bruns, 2009, Stabilization of glucose in blood samples: why it matters, Clin. Chem., 55, 850, 10.1373/clinchem.2009.126037 Stahl, 2001, Optimization of prenalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus, Scand. J. Clin. Lab. Invest., 61, 169, 10.1080/003655101300133612 Marbach, 1975, Sodium iodoacetate as an antiglycolitic agent in blood samples, Clin. Chem., 21, 1810, 10.1093/clinchem/21.12.1810 Chan, 1982, d-Mannose as a preservative of glucose in blood samples, Clin. Chem., 38, 411, 10.1093/clinchem/38.3.411 Uchida, 1988, A new method of inhibiting glycolysis in blood samples, Clin. Chim. Acta, 172, 101, 10.1016/0009-8981(88)90125-8 Mikesh, 2008, Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis, Clin. Chem., 54, 930, 10.1373/clinchem.2007.102160 Gambino, 2013, Sodium fluoride: an ineffective inhibitor of glycolysis, Ann. Clin. Biochem., 50, 3, 10.1258/acb.2012.012135 Gambino, 2009, Acidification of blood is superior to sodium fluoride alone as an inhibitor of glycolysis, Clin. Chem., 55, 1019, 10.1373/clinchem.2008.121707 Sacks, 2011, Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus, Clin. Chem., 57, 793, 10.1373/clinchem.2011.163634 CLSI, 2007, Procedures for the collection of diagnostic blood specimens by venipuncture; approved standard Minchinela, 2014, Biological variation database, and quality specifications for imprecision, bias and total error (desirable and minimum) Chan, 2014, Plasma glucose measurement in diabetes: impact and implications in sample collection procedures with focus on the first hour after sample collection, Clin. Chem. Lab. Med., 52, 1061, 10.1515/cclm-2013-1059 Waring, 2007, Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on reported prevalence of diabetes mellitus, J. Clin. Pathol., 60, 820, 10.1136/jcp.2006.039925 Shi, 2009, Rapid separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration, J. Clin. Pathol., 62, 752, 10.1136/jcp.2008.062547 Turchiano, 2013, Impact of blood sample collection and processing methods on glucose levels in community outreach studies, J. Environ. Public Health, 2013, 256151, 10.1155/2013/256151 Kocjancic, 2014, Evaluation of the BD Vacutainer® RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study, Biochem. Med., 24, 368, 10.11613/BM.2014.039 Van den, 2015, It takes acid, rather than ice, to freeze glucose, Sci. Rep., 5, 8875, 10.1038/srep08875 Lin, 1976, Stabilization of blood glucose by cooling with ice: an effective procedure for preservation of samples from adults and newborns, Clin. Chem., 22, 2031, 10.1093/clinchem/22.12.2031 Lippi, 2006, Influence of hemolysis on routine clinical chemistry testing, Clin. Chem. Lab. Med., 44, 311, 10.1515/CCLM.2006.054 Gambino, 2013, Stabilization of glucose in blood samples: out with the old, in with the new, Clin. Chem. Lab. Med., 51, 1883, 10.1515/cclm-2013-0341 Fobker, 2014, Stability of glucose in plasma with different anticoagulants, Clin. Chem. Lab. Med., 52, 1057, 10.1515/cclm-2013-1049 Dimeski, 2015, What is the most suitable blood collection tube for glucose estimation, Ann. Clin. Biochem., 52, 270, 10.1177/0004563214544708 HAPO Study Cooperative Research Group, 2008, Hyperglycemia and adverse pregnancy outcomes, N. Engl. J. Med., 358, 1991, 10.1056/NEJMoa0707943 Norman, 2014, The shift from fluoride/oxalate to acid citrate/fluoride blood collection tubes for glucose testing—the impact upon patients results, Clin. Biochem., 47, 683, 10.1016/j.clinbiochem.2014.01.011 Ridefelt, 2014, Increased plasma glucose levels after change of recommendation from NaF to citrate blood collection tubes, Clin. Biochem., 47, 625, 10.1016/j.clinbiochem.2014.02.022