Wavefront-guided Excimer Laser Vision Correction After Multifocal IOL Implantation

Journal of Refractive Surgery - Tập 24 Số 3 - Trang 274-279 - 2008
Bettina Jendritza1, Michael C. Knorz, Steve L. Morton
1FreeVis LASIK Center, University of Heidelberg, Medical Faculty Mannheim, Germany.

Tóm tắt

Purpose: To investigate the use of wavefront-guided LASIK after multifocal intraocular lens (IOL) implantation to correct residual ametropia and higher order aberrations. Methods: In a prospective, nonrandomized case series, wavefront-guided LASIK was performed in 27 eyes (19 patients) after multifocal IOL implantation (Tecnis diffractive IOL, n=20; ReSTOR diffractive IOL, n=4; ReZoom refractive IOL, n=3) using the VISX STAR S4 IR excimer laser. Visual acuity, manifest refraction, and wavefront error were examined pre- and 3 months postoperatively. Results: In the Tecnis group, results before (after) LASIK were: sphere +1.06±0.77 diopters (D) (−0.03±0.28 D; P =.0001), cylinder −1.13±0.73 D (−0.14±0.25 D; P =.00004), distance uncorrected visual acuity (UCVA) 20/45±0.09 (20/29±0.16; P =.00004), near UCVA 20/30±0.24 (20/25±0.16; P =.001), and higher order aberrations (4-mm pupil) 0.14±0.05 µm (0.18±0.03 µm; P =.02). Distance and near best spectacle-corrected visual acuity (BSCVA) did not change. In the ReSTOR group, results before (after) LASIK were: sphere +0.75±0.56 D (+0.13±0.22 D), cylinder −1.50±0.47 D (−0.13±0.22 D), distance UCVA 20/40±0.07 (20/26±0.07), near UCVA 20/44±0.05 (20/25±0.0), and higher order aberrations (4-mm pupil) 0.14±0.03 µm (0.20±0.02 µm). Distance and near BSCVA did not change. In the ReZoom group, results before (after) LASIK were: sphere +0.08±1.20 D (0.00 D), cylinder −0.83±0.120 D (0.00 D), distance UCVA 20/40±0 (20/25±0), near UCVA 20/60±0.09 (20/150±0.18), and higher order aberrations (4-mm pupil) 0.43±0.04 µm (0.39±0.03 µm). Patients lost one line of distance BSCVA and two lines of near BSCVA. Conclusions: Wavefront-guided LASIK is safe and effective in diffractive multifocal IOLs to correct residual refractive error, but higher order aberrations did not improve. It is not recommended in refractive multifocal IOLs, as these cannot be measured reliably with current wavefront sensors. [ J Refract Surg . 2008;24:274–279.]

Từ khóa


Tài liệu tham khảo

10.3928/1081-597X-19980501-13

10.1016/j.jcrs.2003.11.056

10.3928/1081-597X-20060301-06

10.1364/JOSAA.23.000539

10.1016/j.jcrs.2006.07.029

10.3928/1081-597X-20050901-07

10.1016/j.jcrs.2005.12.128

10.1016/j.jcrs.2005.07.045

10.1016/j.jcrs.2006.08.029

10.1016/S0886-3350(13)80616-5

10.1016/S0886-3350(13)80014-4

10.1016/S0886-3350(99)00335-1

10.1016/j.ophtha.2005.11.020

10.1016/S0161-6420(91)32205-X

10.1016/j.jcrs.2006.04.015

10.1016/j.jcrs.2006.04.011

10.3928/1081-597X-20060301-17

Lane SS, Morris M, Nordan L, Packer M, Tarantino N, Wallace RB III. Multifocal intraocular lenses. Ophthalmol Clin North Am. 2006;19:89–105.

10.3928/1081597X-20080301-15