Voltage sag ride through using Improved Adaptive Internal Model Controller for doubly fed induction generator wind farms

Computers & Electrical Engineering - Tập 39 - Trang 214-224 - 2013
N. Amuthan1, P. Subburaj2, P. Melba Mary3
1Department of Electrical & Electronics Engineering, PET Engineering College, Valliyoor 627 117, Tamil Nadu, India
2National Engineering College, Kovilpatti, Tamil Nadu, India
3V V College of Engineering, Tisaiyanvilai 627 657, Tirunelveli, Tamil Nadu, India

Tài liệu tham khảo

Zinger, 1997, Annualized wind energy improvement using variable speeds, IEEE Trans Ind Appl, 33, 1444, 10.1109/28.649954 Polinder, 2006, Comparison of direct-drive and geared generator concepts for wind turbines, IEEE Trans Energy Convers, 21, 725, 10.1109/TEC.2006.875476 Mullane, 2005, The inertial response of induction-machine-based wind turbines, IEEE Trans Power Syst, 20, 1496, 10.1109/TPWRS.2005.852081 Hee-Sang Ko, Sylvain Bruey, Juri Jatskevich, Guy Dumont, Ali Moshref. A PI control of DFIG-based wind farm for voltage regulation at remote location. In: IEEE power engineering society general meeting; June 2007. Brekken, 2007, Control of a doubly fed induction wind generator under unbalanced grid voltage conditions, IEEE Trans Energy Convers, 22, 129, 10.1109/TEC.2006.889550 Ko, 2007, Active use of DFIG-based variable-speed wind-turbine for voltage regulation at a remote location, IEEE Trans Power Syst, 22, 1916, 10.1109/TPWRS.2007.908475 Morren, 2005, Ride through of wind turbines with doubly-fed induction generator during a voltage dip, IEEE Trans Energy Convers, 20, 435, 10.1109/TEC.2005.845526 Andreas Petersson. Analysis, modeling and control of doubly-fed induction generators for wind turbines, Ph.D thesis. Chalmers University of Technology; 2005. Amuthan, 2009, Direct model reference adaptive internal model controller for DFIG wind farms, Int J Recent Trends Eng, 1, 7 Kadjoudj, 2007, Modified direct torque control of permanent magnet synchronous motor drives, Int J Sci Tech Autom Control Comput Eng IJ-STA, 1, 167 Behera, 2008, Improved direct torque control of induction motor with dither injection, Sadhana, 33, 551, 10.1007/s12046-008-0042-1 Amuthan, 2009, Dynamic speed response of internal model controller for time delay plant with dither injection, Int J Recent Trends Eng Amuthan N. Direct model reference adaptive internal model controller for DFIG wind farms with dither injection. IEEE-ICPS, IITKGP, December 2009. Boukhezzar Boubekeur, Siguerdidjane Houria. nonlinear control of variable speed wind turbines without wind speed measurement. In: Proceedings of the 44th IEEE conference on decision and control, and the European control conference; 2005. p. 3456–61. Mullane, 2005, Wind-turbine fault ride-through enhancement, IEEE Trans Power Syst, 20, 1929, 10.1109/TPWRS.2005.857390 Boukhezzar, 2010, Comparison between linear and nonlinear control strategies for variable speed wind turbines, Control Eng Practice, 18, 1357, 10.1016/j.conengprac.2010.06.010 Bousseau, 2006, Solutions for the grid integration of wind farms – a survey, Wind Energy, 9, 13, 10.1002/we.177 Tzeng, 1999, An internal model control approach to the design of yaw-rate-Control ship-steering autopilot, IEEE J Oceanic Eng, 24, 507, 10.1109/48.809275 Mohamed, 2008, A current control scheme with an adaptive internal model for torque ripple minimization and robust current regulation in PMSM drive systems, IEEE Trans Energy Convers, 23, 92, 10.1109/TEC.2007.914352 Astom, 1995 Melba Mary, 2009, Design of self – tuning fuzzy logic controller for the control of an unknown industrial process, IET J Control Theory Appl, 3, 428, 10.1049/iet-cta.2007.0334 Angelov, 2002, Identification of evolving fuzzy rule-based models, IEEE Trans Fuzzy Syst, 10, 667, 10.1109/TFUZZ.2002.803499 Angelov, 2004, An approach to online identification of Takagi–Sugeno fuzzy models, IEEE Trans Syst Man Cyber—Part B: Cyber, 34, 484, 10.1109/TSMCB.2003.817053 Amuthan, 2012, Ride through and direct model reference adaptive internal model controller with rule based adjustment mechanisum for DFIG wind farms, Int J Sustainable Energy, 31, 229, 10.1080/1478646X.2011.558899 Saludes S, Fuente MJ, Fault tolerant fuzzy IMC control in a PH process; 2003. <www.nt.ntnu.no/users/skoge/prost/proceedings/ecc03/pdfs/111.pdf>.