Variabilities in X-ray diagnostic reference levels

European Radiology - Tập 30 - Trang 4641-4647 - 2020
Pierre Alain Gevenois1, Denis Tack2, Nigel Howarth3, Thibault Vanaudenhove4, Alain Van Muylem5
1Department of Radiology, Hôpital Erasme, Brussels, Belgium
2Department of Radiology, EpiCURA, Clinique Louis Caty, Baudour, Belgium
3Department of Radiology, Clinique des Grangettes, Chêne-Bougeries, Switzerland
4Federal Agency for Nuclear Control (FANC), Brussels, Belgium
5Department of Chest Medicine, Hôpital Erasme, Brussels, Belgium

Tóm tắt

To estimate the variability of X-ray diagnostic reference levels (DRLs) depending on the number of X-ray devices and data per device. Dose-area products (DAP) were collected by the national nuclear control agency from the 590 devices installed in 345 medical centers in the country. From 2015 to 2017, the number of chest (postero-anterior (PA) view alone, and both postero-anterior and lateral views (PA/LAT)), abdomen, pelvis, and lumbar spine examinations collected in these centers ranged from 23,000 to 77,000. The impact of the number of devices and DAP data per device on DRLs’ variabilities (95th confidence intervals divided by medians) is estimated using a bootstrapping method as a function of the number of devices and DAP per device. The DRLs’ variabilities ranged from 30 to 200% depending on the number of devices and DAP data per device but stabilized at 30% when the number of devices was higher than 200 for chest PA and abdomen examinations, 300 for lumbar spine and pelvis examinations, and 400 for chest PA/LAT examinations, regardless of the number of DAP data per device. Extrapolations of our results suggest that thousands of devices are necessary to reduce DRLs’ variabilities to 10%. DAP-related DRL variabilities are high but only moderately influenced by the number of DAP data per device and of devices provided this number is higher than 200 to 400 devices according to the type of examination. Harmonization of methods of data collection between the authorities of the EU states should be recommended. • DAP-related DRLs are not fixed values but ranges of values with at least 30% variability. • DAP-related DRLs strongly depend on the number of devices included when lower than 100. • If the number of devices included exceeds 200 to 400, the DRLs’ variabilities do not depend on the number of DAP per device and should not exceed 30%.

Tài liệu tham khảo

The council of the European Union (1997) Council Directive 97/43 of 30 June 1997 on health protection of individuals against the dangers of ionizing radiation in relation to medical exposure, and repealing Directive 84/466/Euratom. Available via https://eur-lex.europa.eu/eli/dir/1997/43/oj. Accessed 20 Oct 2019 The council of the European Union (2013) Council Directive 2013/59/Euratom of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation, and repealing Directives 89/618/Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom. Available via https://eur-lex.europa.eu/eli/dir/2013/59/oj. Accessed 20 Oct 2019 Vaño E, Miller DL, Martin CJ et al (2017) ICRP publication 135: diagnostic reference levels in medical imaging. Ann. ICRP 46:1–144 Office Fédéral de Santé Publique (2010) Niveaux de référence diagnostiques. Available via https://www.bag.admin.ch/bag/fr/home/gesetze-und-bewilligungen/gesuche-bewilligungen/bewilligungen-aufsicht-im-strahlenschutz/informationen-fuer-medizinische-betriebe/diagnostische-referenzwerte-im-strahlenschutz.html. Accessed 20 Oct 2019 Agence fédérale de Contrôle nucléaire (2015) Niveaux de référence diagnostiques en radiologie. Available via https://afcn.fgov.be/fr/professionnels/professions-medicales/applications-radiologiques/nrd. Accessed 20 Oct 2016 Stamm G (2012) Collective radiation dose from MDCT. Critical review of survey studies. In: Tack D, Kalra MK, Gevenois PA (eds) Radiation dose from multidetector CT. Springer, Heidelberg, pp 209–229 Tack D, Jahnen A, Kohler S et al (2014) Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit. Eur Radiol 24:169–175 European commission (1998) Radiation Protection 102: implementation of the medical exposure Directive (97/43/Euratom). Proceedings of the international workshop held in Madrid on 27 April 1997. Available via http://ec.europa.eu/energy/sites/ener/files/documents/102_en_0.pdf. Accessed 21 Oct 2019 European commission (1999) Radiation Protection 109: guidance on diagnostic reference levels for medical exposures. Available via https://ec.europa.eu/energy/sites/ener/files/documents/109_en.pdf. Accessed 21 Oct 2019 Shrimpton PC, Hillier MC, Lewis MA, Dunn M (2006) National survey of doses from CT in the UK: 2003. Br J Radiol 79:968–980 Jessen KA, Shrimpton PC, Geleijns J, Panzer W, Tosi G (1999) Dosimetry for optimisation of patient protection in computed tomography. Appl Radiat Isot 50:165–172 Institut de Radioprotection et de Sûreté Nucléaire (2010) Doses délivrées aux patients en scanographie et en radiologie conventionnelle. Résultats d’une enquête multicentrique en secteur public. Rapport DRPH/SER N°2010–12. Available via http://www.irsn.fr/FR/expertise/rapports_expertise/Documents/radioprotection/IRSN-Rapport-dosimetrie-patient-2010-12.pdf. Accessed 22 Sep 2019 Agence fédérale de Contrôle nucléaire (2011) La dosimétrie des patients - Arrêté de l'Agence fédérale de contrôle nucléaire du 28 septembre 2011 concernant la dosimétrie des patients. Available via http://www.jurion.fanc.fgov.be/jurdb-consult/consultatieLink?wettekstId=15119&appLang=fr&wettekstLang=fr. Accessed 20 Oct 2019 National Radiological Protection Board (1992) National Protocol for patient dose measurements in diagnostic radiology. Chilton. Available via https://www.gov.uk/government/uploads/system/uploads/attachment_data/file/337175/National_Protocol_for_Patient_Dose_Measurements_in_Diagnostic_Radiology_for_website.pdf. Accessed 20 Oct 2019 European Commission (2008) European guidance on estimating population doses from medical X-ray procedures. Radiation Protection 154. Luxembourg. Available via https://ec.europa.eu/energy/sites/ener/files/documents/154.zip. Accessed 21 Oct 2019 European Commission (2014) Diagnostic Reference Levels in thirty six European countries. Part 2/2. Radiation Protection 180. Luxembourg. Available via https://ec.europa.eu/energy/sites/ener/files/documents/RP180%20part2.pdf. Accessed 21 Oct 2019 Taylor S, Van Muylem A, Howarth N, Gevenois PA, Tack D (2019) X-ray examination dose surveys: how accurate are my results? Eur Radiol 2019;10:5307–5313 Taylor S, Van Muylem A, Howarth N, Gevenois PA, Tack D (2017) CT dose survey in adults: what sample size for what precision? Eur Radiol 27(1):365–373 The European parliament and the council of the European Union (2016) Regulation (EU) 2016/679 of the European Parliament and of the Council of 27 April 2016 on the protection of natural persons with regard to the processing of personal data and on the free movement of such data, and repealing Directive 95/46/EC. OJ L 119, 4.5.2016, p. 1–88. Available via https://op.europa.eu/en/publication-detail/-/publication/3e485e15-11bd-11e6-ba9a-01aa75ed71a1/ Accessed 24 Oct 2019 de Saint Pol T (2006) Corps et appartenance sociale : la corpulence en Europe. Données sociales 2006 - La société française, Institut National de la Statistique et des Etudes Economiques, pp.649–656. Available via https://halshs.archives-ouvertes.fr/halshs-00109017/document Vanaudenhove T, Van Muylem A, Howarth N, Gevenois PA, Tack D (2019) CT diagnostic reference levels: are they appropriately computed? Eur Radiol 10:5264–5271