Utilization of Ground Heat Exchangers: a Review

Tian Yan1, Xin Xu1
1Huazhong University of Science and Technology

Tóm tắt

Từ khóa


Tài liệu tham khảo

Ascione F, D'Agostino D, Marino C, Minichiello F. Earth-to-air heat exchanger for NZEB in Mediterranean climate. Renew Energy. 2016;99:553–63.

Liu ZB, Zhang L, Gong GC, Li HX, Tang GF. Review of solar thermoelectric cooling technologies for use in zero energy buildings. Energy and Build. 2015;102(1):207–16.

Pacheco R, Ordóñez J, Martínez G. Energy efficient design of building: a review. Renew Sust Energ Rev. August 2012;16(6):3559–73.

• Soni SK, Pandey M, Bartaria VN. Ground coupled heat exchangers: a review and applications. Renew Sustain Energy Rev. 2015;47:83–92. The advantages and applicability of the ground heat exchanger in building heating and cooling systems are generally shown. Its classifications are briefly introduced.

Banks D. An introduction to thermogeology: ground source heating and cooling. 2nd ed. Ames Iowa: Wiley-Blackwell; 2012.

Staiti M, Angelotti A. Design of borehole heat exchangers for ground source heat pumps: a comparison between two methods. Energy Procedia. 2015;78:1147–52.

Ndiaye D. Reliability and performance of direct-expansion ground-coupled heat pump systems: issues and possible solutions. Renew Sustain Energy Rev. 2016;66:802–14.

Hakkaki-Fard A, Eslami-Nejad P, Aidoun Z, Ouzzane M. A techno-economic comparison of a direct expansion ground-source and an air-source heat pump system in Canadian cold climates. Energy. 2015;87(1):49–59.

Wu W, Li X, You T, Wang B, Shi W. Combining ground source absorption heat pump with ground source electrical heat pump for thermal balance, higher efficiency and better economy in cold regions. Renew Energy. 2015;84:74–88.

Huang B, Mauerhofer V. Life cycle sustainability assessment of ground source heat pump in Shanghai, China. J Cleaner Prod. 2016;119(15):207–14.

Y Cui, J Zhu, 3D transient heat transfer numerical analysis of multiple energy piles, Energy and Buildings, Available online 25 2016, ISSN 0378-7788, https://doi.org/10.1016/j.enbuild.2016.10.032 , 3D transient heat transfer numerical analysis of multiple energy piles.

Yang W, Lu P, Chen Y. Laboratory investigations of the thermal performance of an energy pile with spiral coil ground heat exchanger. Energy Build. 2016;128(15):491–502.

Akrouch GA, Sánchez M, Briaud J-L. An experimental, analytical and numerical study on the thermal efficiency of energy piles in unsaturated soils. Comput Geotech. 2016;71:207–20.

Moon C-E, Choi JM. Heating performance characteristics of the ground source heat pump system with energy-piles and energy-slabs. Energy. 2015;81(1):27–32.

Cecinato F, Loveridge FA. Influences on the thermal efficiency of energy piles. Energy. 2015;82(15):1021–33.

Alessandro F, Loria R, Gunawan A, Shi C, Laloui L, Ng CWW. Numerical modelling of energy piles in saturated sand subjected to thermo-mechanical loads. Geomech Energy Environ. 2015;1:1–15.

Bourne-Webb P, Burlon S, Javed S, Kürten S, Loveridge F. Analysis and design methods for energy geostructures. Renew Sust Energ Rev. 2016;65:402–19.

Bandos TV, Campos-Celador Á, López-González LM, Sala-Lizarraga JM. Finite cylinder-source model for energy pile heat exchangers: effects of thermal storage and vertical temperature variations. Energy. 2014;78(15):639–48.

Li D, He J, Li L. A review of renewable energy applications in buildings in the hot-summer and warm-winter region of China. Renew Sust Energ Rev. 2016;57:327–36.

• Eicker U, Vorschulze C. Potential of geothermal heat exchangers for office building climatisation. Renew Energy. 2009;34(4):1126–33. The advantages and potential of the gorund heat exchangers in building heating and cooling systems.

Pfafferott J. Evaluation of earth-to-air heat exchangers with a standardized method to calculate energy efficiency. Energy Build. 2003;35:971–83.

Ascione F, Bellia L, Minichiello F. Earth-to-air heat exchangers for Italian climates. Renew Energy. 2011;36(8):2177–88.

Vaz J, Sattler MA, da Brum RS, dos Santos ED, Isoldi LA. An experimental study on the use of Earth-Air Heat Exchangers (EAHE). Energy Build. 2014;72:122–31.

Bansal V, Misra R, Agrawal GD, Mathur J. Performance analysis of earth–pipe–air heat exchanger for winter heating. Energy Build. 2009;41(11):1151–4.

Uddin Md S, Ahmed R, Rahman M. Performance evaluation and life cycle analysis of earth to air heat exchanger in a developing country. Energy and Build. 2016;128(15):254–61.

Hollmuller P, Lachal B. Air–soil heat exchangers for heating and cooling of buildings: design guidelines, potentials and constraints, system integration and global energy balance. Appl Energy. 2014;119(15):476–87.

Campaniço H, Hollmuller P, Soares PMM. Assessing energy savings in cooling demand of buildings using passive cooling systems based on ventilation. Appl Energy. 2014;134(1):426–38.

Thiers S, Peuportier B. heat exchangers for ground source assessment of a passive building equipped with an earth-to-air heat exchanger in France. Sol Energy. 2008;82(9):820–31.

Zhang J, Haghighat F. Convective heat transfer prediction in large rectangular cross-sectional area Earth-to-Air Heat Exchangers. Build Environ. 2009;44(9):1892–8.

Pomianowski M, Heiselberg P, Jensen RL. Dynamic heat storage and cooling capacity of a concrete deck with PCM and thermally activated building system. Energy Build. 2012;53:96–107.

Romaní J, de Gracia A, Cabeza LF. Simulation and control of thermally activated building systems (TABS). Energy and Build. 2016;127(1):22–42.

Lehmann B, Dorer V, Koschenz M. Application range of thermally activated building systems tabs. Energy Build. 2007;39(5):593–8.

Vangtook P, Chirarattananon S. Application of radiant cooling as a passive cooling option in hot humid climate. Build Environ. 2007;42(2):543–56.

Rijksen DO, Wisse CJ, van Schijndel AWM. Reducing peak requirements for cooling by using thermally activated building systems. Energy Build. 2010;42(3):298–304.

Romaní J, Pérez G, de Gracia A. Experimental evaluation of a cooling radiant wall coupled to a ground heat exchanger. Energy Build. 2016;129(1):484–90.

Xu X, Wang S, Wang J, Xiao F. Active pipe-embedded structures in buildings for utilizing low-grade energy sources: a review. Energy Build. 2010;42(10):1567–81.

Niu F, Yu Y. Location and optimization analysis of capillary tube network embedded in active tuning building wall. Energy. 2016;97(15):36–45.

• Li A, Xu X, Sun Y. A study on pipe-embedded wall integrated with ground source-coupled heat exchanger for enhanced building energy efficiency in diverse climate regions. Energy and Build. 2016;121:139–51. Typical cases for passive utilization of ground heat exchangers in different systems and forms.

Krzaczek M, Kowalczuk Z. Thermal Barrier as a technique of indirect heating and cooling for residential buildings. Energy and Buildi. 2011;43(4):823–37.

Serres S, Trombe A, Conilh HJ. Study of coupled energy saving systems sensitivity factor analysis. Build Environ. 1997;32(2):137–48.

Xu X, Yu J, Wang S, Wang J. Research and application of active hollow core slabs in building systems for utilizing low energy sources. Appl Energy. 2014;116(1):424–35.

Zhu N, Hu P, Yu L, Jiang Z, Lei F. Numerical study on ground source heat pump integrated with phase change material cooling storage system in office building. Appl Thermal Eng. 2015;87(5):615–23.

Georgios F, Soteris K. Ground heat exchangers—a review of systems, models and applications. Renew Energy. 2007;32(15):2461–78.

Zhang S, Zhang L, Wei H, Jing J, Zhou X, Zhang X. Field testing and performance analyses of ground source heat pump systems for residential applications in Hot Summer and Cold Winter area in China. Energy Build. 2016;133(1):615–27.

Na Z, Pingfang H, Linghong X, Jiang Z, Lei F. Recent research and applications of ground source heat pump integrated with thermal energy storage systems: a review. Appl Thermal Eng. 2014;71(1):142–51.

Liu Z, Xu W, Cheng Q, Chen X, Jin G. Investigation on the feasibility and performance of ground source heat pump (GSHP) in three cities in cold climate zone, China. Renew Energy. 2015;84:89–96.

Yang H, Cui P, Fang Z. Vertical-borehole ground-coupled heat pumps: a review of models and systems. Appl Energy. 2010;87(1):16–27.

• Luo J, Rohn J, Bayer M, Priess A, Wilkmann L, Xiang W. Heating and cooling performance analysis of a ground source heat pump system in Southern Germany. Geothermics. 2015;53:57–66. Typical case of active utilization of ground heat exchanger. Itspreformance for heating and cooling is analyzed.

Sivasakthivel T, Murugesan K, Sahoo PK. Optimization of ground heat exchanger parameters of ground source heat pump system for space heating applications. Energy. 2014;78(15):573–86.

Hein P, Kolditz O, Görke U-J, Bucher A, Shao H. A numerical study on the sustainability and efficiency of borehole heat exchanger coupled ground source heat pump systems. Appl Thermal Eng. 2016;100(5):421–33.

Bojić M. Optimization of heating and cooling of a building by employing refuse and renewable energy. Renew Energy. 2000;20(4):453–65.

• Misra R, Bansal V, Agarwal GD, Mathur J, Aseri T. Thermal performance investigation of hybrid earth air tunnel heat exchanger. Energy and Build. 2012;49:531–5. Typical cases for active utilization of ground heat exchangers based on different medium.