Using a New Criterion to Identify Sites for Mean Soil Water Storage Evaluation

Soil Science Society of America Journal - Tập 74 Số 3 - Trang 762-773 - 2010
Wei Hu1,2, Mingan Shao3,4, Klaus Reichardt5
1Graduate Univ., Chinese Academy of Sciences, Beijing, 100039 China
2Key Lab. of Water Cycle and Related Surface Processes, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing, 100101 China
3Institute of Soil And Water Conservation, Chinese Academy of Sciences, Ministry of Water Resource, Yangling, 712100 Shaanxi, China
4State Key Lab. of Soil Erosion and Dryland Farming on the Loess Plateau Institute of Soil and Water Conservation, Northwest A & F Univ
5Lab. of Soil Physics, Center for Nuclear Energy in Agriculture Univ. of São Paulo CEP 13418‐900, CP 96 Piracicaba SP Brazil

Tóm tắt

Establishing a few sites in which measurements of soil water storage (SWS) are time stable significantly reduces the efforts involved in determining average values of SWS. This study aimed to apply a new criterion—the mean absolute bias error (MABE)—to identify temporally stable sites for mean SWS evaluation. The performance of MABE was compared with that of the commonly used criterion, the standard deviation of relative difference (SDRD). From October 2004 to October 2008, SWS of four soil layers (0–1.0, 1.0–2.0, 2.0–3.0, and 3.0–4.0 m) was measured, using a neutron probe, at 28 sites on a hillslope of the Loess Plateau, China. A total of 37 SWS data sets taken over time were divided into two subsets, the first consisting of 22 dates collected during the calibration period from October 2004 to September 2006, and the second with 15 dates collected during the validation period from October 2006 to October 2008. The results showed that if a critical value of 5% for MABE was defined, more than half the sites were temporally stable for both periods, and the number of temporally stable sites generally increased with soil depth. Compared with SDRD, MABE was more suitable for the identification of time‐stable sites for mean SWS prediction. Since the absolute prediction error of drier sites is more sensitive to changes in relative difference in terms of mean SWS prediction, the sites of wet sectors should be preferable for mean SWS prediction for the same changes in relative difference.

Từ khóa


Tài liệu tham khảo

10.1016/j.jhydrol.2005.08.024

Brocca L., 2008, Soil moisture temporal stability over experimental areas in central Italy, Geoderma, 148, 364, 10.1016/j.geoderma.2008.11.004

10.2134/agronj2000.924706x

10.1016/j.geoderma.2007.10.013

10.1016/0016-7061(94)90042-6

10.1016/j.rse.2004.02.016

10.1016/j.rse.2007.07.001

10.1016/j.jhydrol.2005.08.020

10.1016/j.jhydrol.2006.06.016

10.1002/(SICI)1099-1085(200005)14:7<1261::AID-HYP40>3.0.CO;2-D

10.1016/S0022-1694(98)00096-1

10.1016/j.catena.2007.09.010

10.1590/S0103-90162008000300008

10.1016/j.catena.2009.05.012

10.1016/j.rse.2004.02.017

10.2136/vzj2005.0058

10.2136/sssaj2003.1647

10.1016/j.jhydrol.2005.02.007

10.1016/S0309-1708(01)00034-3

10.1016/j.jhydrol.2008.06.016

10.1016/j.jhydrol.2005.09.024

10.1016/S0022-1694(03)00077-5

10.2136/sssaj1985.03615995004900040006x