Use of YAP(Ce) in the development of high spatial resolution radiation imaging detectors

Radiation Measurements - Tập 119 - Trang 184-191 - 2018
Seiichi Yamamoto1, Kei Kamada2, Akira Yoshikawa2,3
1Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Japan
2New Industry Creation Hatchery Center (NICHe), Tohoku University, Japan
3Institute for Materials Research (IMR), Tohoku University, Japan

Tài liệu tham khảo

Ando, 2017, Development of a low-energy x-ray camera for the imaging of secondary electron Bremsstrahlung X-ray emitted during proton irradiation for range estimation, Phys. Med. Biol., 62, 5006, 10.1088/1361-6560/aa7166 Aoi, 2006, System design and development of a pinhole SPECT system for quantitative function imaging of small animals, Ann. Nucl. Med., 20, 245, 10.1007/BF03027438 Beekman, 2007, The pinhole: gateway to ultra-high-resolution three dimensional radionuclide imaging, Eur. J. Nucl. Med. Mol. Imag., 34, 151, 10.1007/s00259-006-0248-6 Kapusta, 1999, A high-energy resolution observed from a YAP:Ce scintillator, Nucl. Instrum. Methods Phys. Res., 421, 610, 10.1016/S0168-9002(98)01232-7 Klamra, 2009, Light yield non-proportionality of undoped YAP scintillator, J. Instrum., 4, P05006, 10.1088/1748-0221/4/05/P05006 Morishita, 2014, Development of a Si-PM based alpha camera for plutonium detection in nuclear fuel facilities, Nucl. Instrum. Methods Phys. Res., Sect. A, 747, 81, 10.1016/j.nima.2013.12.052 Morishita, 2014, Performance comparison of scintillators for alpha particle detectors, Nucl. Instrum. Methods Phys. Res., 764, 383, 10.1016/j.nima.2014.07.046 Moses, 2012, The origins of scintillator non-proportionality, IEEE Trans. Nucl. Sci., 59, 2038, 10.1109/TNS.2012.2186463 Moszyński, 1998, Properties of the YAP:Ce scintillator, Nucl. Instrum. Methods Phys. Res., 404, 157, 10.1016/S0168-9002(97)01115-7 Tanaka, 1970, Scintillation cameras based on new position arithmetics, J. Nucl. Med., 11, 542 Yamaguchi, 2018, Imaging of monochromatic beams by measuring secondary electron Bremsstrahlung for carbon-ion therapy using a pinhole X-ray camera, Phys. Med. Biol., 63, 045016, 10.1088/1361-6560/aaa17c Yamamoto, 2006, Resolution improvement using a fiber optic plate for a small field-of-view NaI(Tl) gamma camera, IEEE Trans. Nucl. Sci., 53, 49, 10.1109/TNS.2005.862965 Yamamoto, 2010, Development of a compact and high spatial resolution gamma camera system using LaBr3(Ce), Nucl. Instrum. Methods Phys. Res., Sect. A, 622, 261, 10.1016/j.nima.2010.07.038 Yamamoto, 2016, Development of a high resolution gamma camera system using finely grooved GAGG scintillator, Nucl. Instrum. Methods Phys. Res., 821, 28, 10.1016/j.nima.2016.03.060