Dabela-Biketi, 2020, Urethrographic evaluation of anatomic findings and complications after perineal masculinization and phalloplasty in transgender patients, Radiographics., 40, 393, 10.1148/rg.2020190143
Hart, D., Jones, D.G., Wall, B.F., 1994. National Radiological Protection Board. Estimation of Effective Dose in Diagnostic Radiology from Entrance Surface Dose and Dose-Area Product Measurements. NRPB Report 262, Chilton, Oxon, U.K.
ICRP 1991. International commission on radiological protection, 1990 recommendations of the international commission on radiological protection. New York: Elsivier; Ann. ICRP 21(1-–), 1–146.
ICRP, 2007. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann. ICRP 37 (2-4), 1–399.
ICRP, 2010. International Commission of Radiological Protection. 2010. Radiological Protection in Fluoroscopically Guided Procedures Performed Outside the Imaging Department. ICRP publication 117, Annals of ICRP 40(6), 1–133.
Livingstone, 2004, Evaluation of work practices and radiation dose during adult micturating cystourethrography examinations performed using a digital imaging system, British J. Radiol., 77, 927, 10.1259/bjr/32730898
Mahesh, 2001, Fluoroscopy: Patient Radiation Exposure Issues, RadioGraphics., 21, 1033, 10.1148/radiographics.21.4.g01jl271033
Martin, 1998, Protocol for measurement of patient entrance surface dose rates for fluoroscopic X-ray equipment, Br. J. Radiol, 71, 1283, 10.1259/bjr.71.852.10319002
Martinez-Pineiro, L., Djakovic N., Plas, E., et al., 2010. EAU guidelines on urethral trauma. Eur. Urol. 57, 791–803.
NCRP Report 160, 2009. National Council on Radiation Protection and Measurements. Ionizing Radiation Exposure of the Population of the United States.(2009). NCRP Report 160. National Council on Radiation Protection and Measurements, Bethesda, MD.
Ngaile, 2018, Monte Carlo based estimation of organ and effective doses to patients undergoing hysterosalpingography and retrograde urethrography fluoroscopy procedures, Radiat. Phys. Chem., 145, 148, 10.1016/j.radphyschem.2017.10.015
Perisinakis, 2002, Assessment of patient effective radiation dose and associated radiogenic risk from extracorporeal shock-wave lithotripsy, Health. Phys., 83, 847, 10.1097/00004032-200212000-00012
Sandilos, 2006, Radiation doses to patients from extracorporeal shock wave lithotripsy, Health Phys., 90, 583, 10.1097/01.HP.0000196112.94905.dd
Sulieman, 2015, Measurement of patient radiation doses in certain urography procedures, Radiat. Prot. Dosim., 165, 397, 10.1093/rpd/ncv185
Sulieman, 2007, Radiation dose measurement and risk estimation for paediatric patients undergoing micturating cystourethrography, Br J Radiol, 80, 731, 10.1259/bjr/16010686
Sulieman, 2008, Radiation dose optimisation and risk estimation to patients and staff during hysterosalpingography, Radiat. Prot. Dosim., 128, 217, 10.1093/rpd/ncm324
Sulieman, 2020, Radiation exposure management techniques during endoscopic retrograde cholangio-pancreatography procedures, Radiat. Phys Chem., 108991, 1
Wambani, 2014, Patient radiation exposure during general fluoroscopy examinations, J. Appl. Clin. Med. Phys., 15, 262, 10.1120/jacmp.v15i2.4555